Briggs & Stratton PRO8000 01934 owner manual When Adding or Draining Fuel, When Starting Equipment

Page 3

BSPP Generator

DANGER

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide will cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

DANGER

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

DANGER

Storage batteries give off explosive hydrogen gas during recharging.

Hydrogen gas stays near battery for a long time after battery has been charged.

Slightest spark will ignite hydrogen and cause explosion.

You can be blinded or severely injured.

Battery electrolyte fluid contains acid and is extremely caustic.

Contact with battery fluid will cause severe chemical burns.

DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery.

Wear protective goggles, rubber apron, and rubber gloves.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING OR DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap and air cleaner are in place.

DO NOT crank engine with spark plug removed.

If fuel spills, wait until it evaporates before starting engine.

WHEN OPERATING EQUIPMENT

Do not tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in bodily injury and/or property damage.

3

Image 3
Contents PRO8000 01934 Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Electric Start AssemblyCheck Battery / Attach Negative Battery Wire Carton ContentsAdd Engine Oil When Adding FuelBefore Starting the Engine Add FuelGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundConnecting Electrical Loads Operating GeneratorStarting the Engine Operating Automatic Idle Control Charging a BatteryHow to Use the Battery Charger Stopping the EngineReceptacles Cold Weather Operation120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 30 Amp Locking Receptacle Volt AC, 20 Amp, Duplex ReceptacleVolt DC, 10 Amp Receptacle Gfci Circuit Breaker Ground Fault ProtectionPower Management Dont Overload GeneratorCapacity Generator Maintenance SpecificationsGeneral Maintenance Recommendations Fuel Valve Maintenance Engine MaintenanceGenerator Storage Battery MaintenanceGenerator Cleaning StorageProblem Cause Correction TroubleshootingBspp Generator Limited Warranty Avertissement Symboles de Danger et MoyensTable DES Matières Description DE L ÉquipementLorsque Léquipement Fonctionne Le générateur produit une tension élevéeLors DE Lajout OU DE LA Vidange DU Carburant Lors DU Démarrage DE LéquipementUnintentional peut résulter dans feu ou électrique Lorsque Vous Réglez OU Réparez Votre GénérateurLors DE Tests Dallumage DU Moteur Connaissez Votre Générateur Enlever le générateur de la boite InstallationAssemblage Démarrage ÉlectriqueLors DE Lajout DU Carburant Avant LE Démarrage DU MoteurAjoutez de lhuile à moteur Ajoutez de lessenceBranchement au système électrique dun édifice Emplacement de la GénératriceUtilisation DE LA Génératrice Mise à la terre du systèmeUtilisation DU Générateur Démarrage du MoteurBranchement des Charges Électriques Comment Utiliser le Chargeur de Batterie Arrêt du MoteurFonctionnement du Contrôle Automatique du Ralenti Recharge d’une BatterieExploitation PAR Temps Froid Prises DE CourantPrise à Verrouillage de 120/240 Volts c.a., 30 Ampères Prise à Verrouillage de 120 Volts c.a., 30 Ampères Volts c.a., 20 Ampères Prise de Courant DoublePrise de 10 Ampères, 12 Volts c.c Protection contre les fuites de terre Mise à lessai du disjoncteur GfciPendant le fonctionnement de la génératrice Exemple NE PAS Surcharger GénérateurCapacité Gestion de la ConsommationEntretien du Générateur Recommandations Générales D’ENTRETIENSpécifications Entretien du MoteurRemisage Dépannage Remarques Garantie Limitée Instrucciones DE Seguridad Tabla DE ContenidosDescripción DEL Equipo AdvertenciaCuando Opere EL Equipo PeligroCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Tomacorriente Gfci Dobles de 120 Voltios AC, 20 AmpTomacorriente con Dispositivo de Seguridad de Contenido de la Caja MontajeArranque Eléctrico Para Retirar el Generador de la CajaCuando Añada Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorOperando EL Generador Precaución Encienda el MotorConexion De Cargas Electricas Cómo al Uso el Corcel de Batería Parado Del MotorFuncionamiento del Control Automático de Marcha en Vacío Carga de la BateriaOperación Durante UN Clima Frío Peligro Receptáculos Precaución120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Tomacorrientes de 120 Voltios AC, 30 Amperios Volt AC, 20 Amperios, Receptáculos DoblesTomacorrientes de 12 Voltios DC Protección Contra Fallos de Conexión a Tierra Compruebe el Disyuntor GfciMientras se Utiliza el Generador Ejemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaMantenimiento del Generador EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorAlmacenamiento Diagnositicos DE Averías Notas Notas Garantía Limitada