To bring up a HyperTerminal session on a Win32 platform: Go to Start, Programs, Accessories, Communications, HyperTerminal
•HyperTerminal setup screens:
—“Connection Description” Panel:
•Enter name.
—“Connect To” Panel:
•Select host com2 port (or whichever port you are using).
—Port Settings:
•Bits per second: 115200
•Data Bits: 8
•Parity: none
•Stop Bits: 1
•Flow Control: none
—Start HyperTerminal:
•Select Call from HyperTerminal panel.
—Reset or power up IQ80321 board.
—The Host screen reads:
RedBoot(tm) debug environment - built dd:mm:yy, Mon dd 2001
Platform: IQ80321
Copyright (C) 2000, Red Hat, Inc.
RAM:
FLASH: 0x00000000 - 0x00800000, 64 blocks of 0x00020000 bytes each.
IP: 192.168.0.1, Default server: 0.0.0.0
RedBoot>
For further information on the GDB/Insight Debugger, refer to the content of the GNUPro CD and/or the GNUPro Debugging Tools manual. This setup assumes that Redboot is Flashed on the board.