Thermal Metrology
Figure 5-9. Applying the Adhesive on the Thermocouple Bead
5.1.6Curing Process
1.Let the thermocouple attach sit in the open air for at least half an hour. Using any curing accelerator like Loctite 7452 Accelerator* for this step is not recommended. Rapid contraction of the adhesive during curing may weaken bead attach on the IHS.
2.Reconfirm electrical connectivity with DMM before removing the micromanipulator (Figure
3.Remove the 3D Arm needle by holding down the MCH unit and lifting the arm.
4.Remove the Kapton tape, straighten the wire in the groove so it is flat all the way to the end of the groove (Figure
5.Using a blade, shave excess adhesive above the IHS surface (Figure
Note: | Take usual precautions when using open blades. |
6.Install new Kapton tape to hold the thermocouple wire down and fill the rest of groove with adhesive (See Figure
7.Curing time for the rest of the adhesive in the groove can be reduced using Loctite 7452 Accelerator.
8.Repeat step 5 to remove any access adhesive to ensure flat IHS for proper mechanical contact to the heatsink surface.
Intel® 631xESB/632xESB I/O Controller Hub Thermal Mechanical Design Guide | 23 |