Cooper Lighting Radio manual Maintaining and Servicing the WR 3M, Changing the Filter

Page 16

Page 16 of 21

WR 3M

2.Select the menu item FCC in Menu 2.

3.Depress the UP Scroll Key. Control point 842 °F / 450 °C is selected.

The soldering tip is now heated to 842 °F / 450 °C.

The Heater Control Indicator flashes ( ) (21) as soon as the temperature is constant.

4.Compare the temperatures indicated by the meter with the indications in the display.

5.Use the UP or DOWN Scroll Key to set the difference between the

value indicated on the external meter and the value indicated on the Rework Station, (shown in small script in lower part of the display). Maximum temperature adjustment: ± 72 °F (± 40 °C).

 

 

Example:

 

 

 

 

Display 842 °F, external meter 840 °F: setting S 2

Note

Display 842 °F, external meter 844 °F: setting T 2

Depress Radio Button ┌ 3 ┐ to exit the menu item without saving

 

 

changes (EXIT).

6.Depress Radio Button ┌ 2 ┐ (Set) to confirm the value.

The temperature deviation is now reset to 0. Factory Control Check at 842 °F / 450 °C is now complete.

7.Exit Menu 2 by depressing Radio Button ┌ 3 ┐ twice.

Setting the Pick-Up Vacuum Level

This function can be used to set the vacuum level of the vacuum pick-up pump operation:

Factory setting: 85 %

Variable: 50 % – 100 %

1. Select the menu item LEVEL in Menu 2. “PIC UP” appears in the display

2.Set the Pick-up level with the UP or DOWN scroll keys.

3.Proceed to the next menu item with the button ┌ 1 ┐ (back) or

2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Note: The “ FCC “ Offset values can be reset to the Factory Setting in the Special Functions Menu 2 without affecting other settings of the Rework Station. ( See “Resetting the Special Functions to Factory Default Settings” on page 14 of 21. )

*For Details concerning “FCC“ Default Settings, please contact Weller Technical Services.

8 Maintaining and Servicing the WR 3M

8.1Changing the Filter

Regularly check the main filters for “VACUUM” and “AIR” and replace if necessary.

Image 16
Contents Buttons 1 , 2 Button 1·2·3Air Receptacle 1 , 2Table of Contents InstructionsPacking List Safety InformationDescription DXV 80 WR3000M Tools and HoldersWP 80 WR3000M WR 3M Technical Data USB PortInitial Set-up Connected to the air portSetting the Temperature Selecting a channel, switching on or OFFOperating Guidelines Setting the Pre-set Temperature on Radio Buttons 1 , 2 or Setting the Air FlowTemperature Setting using the Radio Buttons 1 , 2 or Switching the Vacuum Pick-up Pump ON/OFF Special FunctionsSoldering and Desoldering Selecting Menu 1 Special FunctionsSetting the Standby Temperature Possibility of manual temperature reduction Setback whenSetback Time Soldering / desoldering tool is not in useSetting the Automatic Switch-Off Time AUTO-OFF Settings Tool Operation without Switching HolderTool Operation with Switching Holder OFF functionsSwitching the Temperature Display Setting the Window FunctionLimiting the Time HAP on time for Hot-Air Pencil Setting the Vacuum OFF delay VAC OFF Setting the Vacuum on delay VAC onSwitching the Lock Function On/Off Depressing the Radio buttons 1 or 2 while OFF is displayedResetting the Special Functions to Factory Default Settings Setting the Station Identification Remote ID codeSelecting Menu 2 Special Functions Special Functions NavigationChanges Exit Factory Control Check FCCControl Check at 212 F / 100 C Depress Radio Button 3 to exit the menu item without savingMaintaining and Servicing the WR 3M Setting the Pick-Up Vacuum LevelChanging the Filter Fault Indications and Correction Indication/symptom Possible cause Corrective ActionAccessories Warranty DisposalWR 3M XX XXX XX / 03.07 2007 Cooper Industries