Cooper Lighting Radio Setting the Vacuum OFF delay VAC OFF, Setting the Vacuum on delay VAC on

Page 13

WR 3M

Page 13 of 21

the airflow is activated as long as the push-button on the hot-air pencil is depressed.

1. Select the menu item HAP-Onin Menu 1.

2. Set the time value with the UP or DOWN Scroll Key.

3. Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Setting the Vacuum OFF delay (VAC OFF)

To prevent the Desoldering tip from becoming clogged, it is possible to set a vacuum OFF delay of 0 to 5 seconds (factory setting 2 seconds).

1. Select the menu item VAC OFF in Menu 1.

2. Set the time value (VAC OFF) with the UP or DOWN Scroll Key.

3. Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Setting the Vacuum ON delay (VAC ON)

In order to prevent the pump from starting before the solder has melted. Or to create a defined soldering-joint preheat time, it is possible to set an ON delay of 0 to 9 seconds (factory setting 0 seconds: Off).

1. Select the menu item VAC ON in Menu 1.

2. Set the time value (VAC ON) with the UP or DOWN Scroll Key.

3. Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Switching the Lock Function (On/Off)

When the Lock has been switched on, only the Radio Buttons ┌ 1 ┐, ┌ 2 ┐ and ┌ 3 ┐ on the Rework Station can still be operated. All other settings are disabled until the Rework Station is unlocked again.

To LOCK the Rework Station:

 

 

 

 

 

 

1.

Select the menu item LOCK in Menu 1.

 

 

 

Note

 

"OFF“ appears in the display. The padlock symbol flashes.

 

 

 

Depressing the Radio buttons ┌ 1 ┐ or ┌ 2 ┐ while "OFF“ is displayed

 

 

 

 

 

 

results in the menu item being exited without a stored lock code.

 

 

 

 

 

 

2.

Set a 1, 2, or 3-digit Lock code with the UP or DOWN Scroll Key.

 

 

 

 

 

 

 

Note: The code must be retained to Unlock the station.

 

 

 

 

 

 

3.

Depress Radio Button ┌ 3 ┐ for 5 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

The code is stored. The padlock symbol is displayed. The Station

 

 

 

 

 

 

 

is now locked.

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

To unlock the Rework Station:

1.Select the menu item LOCK in Menu 1.

"ON“ appears in the display. The padlock symbol is displayed.

Image 13
Contents Button 1·2·3 Buttons 1 , 2Air Receptacle 1 , 2Instructions Table of ContentsPacking List Safety InformationDescription DXV 80 WR3000M Tools and HoldersWP 80 WR3000M USB Port WR 3M Technical DataConnected to the air port Initial Set-upSetting the Temperature Selecting a channel, switching on or OFFOperating Guidelines Setting the Pre-set Temperature on Radio Buttons 1 , 2 or Setting the Air FlowTemperature Setting using the Radio Buttons 1 , 2 or Special Functions Switching the Vacuum Pick-up Pump ON/OFFSoldering and Desoldering Selecting Menu 1 Special FunctionsPossibility of manual temperature reduction Setback when Setting the Standby TemperatureSetback Time Soldering / desoldering tool is not in useSettings Tool Operation without Switching Holder Setting the Automatic Switch-Off Time AUTO-OFFTool Operation with Switching Holder OFF functionsSwitching the Temperature Display Setting the Window FunctionLimiting the Time HAP on time for Hot-Air Pencil Setting the Vacuum on delay VAC on Setting the Vacuum OFF delay VAC OFFSwitching the Lock Function On/Off Depressing the Radio buttons 1 or 2 while OFF is displayedSetting the Station Identification Remote ID code Resetting the Special Functions to Factory Default SettingsSelecting Menu 2 Special Functions Special Functions NavigationFactory Control Check FCC Changes ExitControl Check at 212 F / 100 C Depress Radio Button 3 to exit the menu item without savingMaintaining and Servicing the WR 3M Setting the Pick-Up Vacuum LevelChanging the Filter Indication/symptom Possible cause Corrective Action Fault Indications and CorrectionAccessories Disposal WarrantyWR 3M XX XXX XX / 03.07 2007 Cooper Industries