Cooper Lighting Radio manual Tools and Holders, DXV 80 WR3000M, WP 80 WR3000M

Page 4

Page 4 of 21

WR 3M

The desired temperature can be adjusted in the range of 150°F to 999°F for hot-air tools and the WSP150 Soldering Iron; 150°F to 850°F for all other soldering / desoldering tools. Set and Read values are displayed in digital form. Three Radio Buttons are used to select fixed / pre-set temperatures directly. The Heater Control Indicator

(" “ symbol in the display), along with a green LED above the port being monitored, flashes to indicate when the Set temperature has been reached.

4.1Tools and Holders

When not in use all tools should be placed in their proper Tool

Holder.

HAP 200: ( WR3000M )

The HAP 200 Hot Air Tools 200 watt heater produces a temperature range of 122°F (50°C) to 1000°F (550°C). The integrated finger switch and a wide assortment of nozzles make it suitable for multiple applications, including soldering or desoldering surface mount components using hot air. The ionizing circuit incorporated in the tool, along with the antistatic handle and hose, provides static free hot air.

DXV 80: ( WR3000M )

The DXV 80 is an 80W Desoldering Tool with an in-line filter and an eccentric taper lock system for the desoldering tiplet. The in-line solder collection chamber is an integral part of the handle and can easily be changed without the use of tools. This tool has a wide range of available desoldering tiplets for multiple applications. Vacuum is activated by depressing the finger switch located on the handle.

WP 80: ( WR3000M )

The WP 80 Soldering Iron is characterized by fast heat-up and precise control of the soldering tip. Due to its slim design, 80W heater output and short reach ( tip to grip ), this tool can be used for a variety of applications, from extremely fine soldering tasks to those requiring high temperatures.

WDH 10 ; ( Tool Holder for WP 80 )

WDH 30 ; ( Tool Holder for HAP 200 )

WDH 40 ; ( Tool Holder for DXV 80 )

See ‘‘Accessories‘‘ for additional tools.

Image 4
Contents Buttons 1 , 2 Button 1·2·3Air Receptacle 1 , 2Table of Contents InstructionsPacking List Safety InformationDescription DXV 80 WR3000M Tools and HoldersWP 80 WR3000M WR 3M Technical Data USB PortInitial Set-up Connected to the air portSetting the Temperature Selecting a channel, switching on or OFFOperating Guidelines Setting the Pre-set Temperature on Radio Buttons 1 , 2 or Setting the Air FlowTemperature Setting using the Radio Buttons 1 , 2 or Switching the Vacuum Pick-up Pump ON/OFF Special FunctionsSoldering and Desoldering Selecting Menu 1 Special FunctionsSetting the Standby Temperature Possibility of manual temperature reduction Setback whenSetback Time Soldering / desoldering tool is not in useSetting the Automatic Switch-Off Time AUTO-OFF Settings Tool Operation without Switching HolderTool Operation with Switching Holder OFF functionsSwitching the Temperature Display Setting the Window FunctionLimiting the Time HAP on time for Hot-Air Pencil Setting the Vacuum OFF delay VAC OFF Setting the Vacuum on delay VAC onSwitching the Lock Function On/Off Depressing the Radio buttons 1 or 2 while OFF is displayedResetting the Special Functions to Factory Default Settings Setting the Station Identification Remote ID codeSelecting Menu 2 Special Functions Special Functions NavigationChanges Exit Factory Control Check FCCControl Check at 212 F / 100 C Depress Radio Button 3 to exit the menu item without savingMaintaining and Servicing the WR 3M Setting the Pick-Up Vacuum LevelChanging the Filter Fault Indications and Correction Indication/symptom Possible cause Corrective ActionAccessories Warranty DisposalWR 3M XX XXX XX / 03.07 2007 Cooper Industries