  | requires a Station Identification (ID code) so that it can clearly be  | |
  | 
  | 
  | 
  | identified.  | |
  | 
  | 
  | 
  | 1.  | Select the menu item REMOTE ID in Menu 2.  | 
  | 
  | 
  | 
  | 2.  | Enter an ID with the UP or DOWN Scroll Keys  | 
  | 
  | 
  | 
  | 
  | (possible values 0 – 999). | 
  | 
  | 
  | 
  | 3.  | Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back)  | 
  | 
  | 
  | 
  | 
  | or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).  | 
  | 
  | Note  | Depress Radio Button ┌ 3 ┐ to exit the menu item without saving any  | ||
  | 
  | 
  | 
  | changes (EXIT). | |
  | 
  | 
  | 
  | Factory Control Check ( FCC ) | |
  | 
  | 
  | 
  | This function checks temperature accuracy of the Rework Station  | |
  | 
  | 
  | 
  | and allows modifications if necessary. To perform the “FCC” function,  | |
  | 
  | 
  | 
  | the soldering tip temperature must be measured using an external  | |
  | 
  | 
  | 
  | temperature measuring instrument, (WA2000) and appropriate type  | |
  | 
  | 
  | 
  | “K” temperature measuring tip. ( See Accessories List on page 18 )  | |
  | 
  | 
  | 
  | Control Check at 212 °F / 100 °C | |
  | 
  | 
  | 
  | 1.  | Connect the type “K” thermocouple, into the external temperature  | 
  | 
  | 
  | 
  | 
  | measuring instrument, (WA2000).  | 
  | 
  | 
  | 
  | 2.  | Select the menu item FCC in Menu 2.  | 
  | 
  | 
  | 
  | 3.  | Depress the DOWN Scroll Key. Control point 212 °F / 100 °C is  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | selected.  | 
  | 
  | 
  | 
  | 
  | The soldering tip is now heated to 212 °F / 100 °C.  | 
  | 
  | 
  | 
  | 
  | The Heater Control Indicator flashes ( ) (21) as soon as the  | 
  | 
  | 
  | 
  | 
  | temperature is constant.  | 
  | 
  | 
  | 
  | 4.  | Compare the temperatures indicated by the meter with the  | 
  | 
  | 
  | 
  | 
  | indications in the display.  | 
  | 
  | 
  | 
  | 5.  | Use the UP or DOWN Scroll Key to set the difference between the  | 
  | 
  | 
  | 
  | 
  | value indicated on the external meter and the value indicated on  | 
  | 
  | 
  | 
  | 
  | the Rework Station, (shown in small script in lower part of the  | 
  | 
  | 
  | 
  | 
  | display). Maximum temperature adjustment: ± 72 °F (± 40 °C).  | 
  | 
  | 
  | 
  | 
  | Example:  | 
  | 
  | 
  | 
  | 
  | Display 212 °F, external meter 210 °F: setting S 2  | 
  | 
  | Note  | 
  | Display 212 °F, external meter 214 °F: setting T 2  | |
  | 
  | Depress Radio Button ┌ 3 ┐ to exit the menu item without saving | |||
  | 
  | 
  | 
  | changes (EXIT).  | |
  | 
  | 
  | 
  | 6.  | Depress Radio Button ┌ 2 ┐ (Set) to confirm the value.  | 
  | 
  | 
  | 
  | 
  | The temperature deviation is now reset to 0. Factory Control  | 
  | 
  | 
  | 
  | 
  | Check at 212 °F / 100 °C is now complete.  | 
  | 
  | 
  | 
  | 7.  | Exit Menu 2 by depressing Radio Button ┌ 3 ┐ twice.  | 
Control Check at 842 °F / 450 °C
1. Connect the type “K” thermocouple, into the external temperature measuring instrument, (WA2000).