Cooper Lighting Radio manual Setting the Window Function, Switching the Temperature Display

Page 12

Page 12 of 21

WR 3M

1)Not in use = UP/DOWN Scroll Keys not depressed and no temperature drop > 41 °F.

2)STANDBY temperature must be below the Set temperature, otherwise the SETBACK function is inactive.

3)When a switching holder is connected, the soldering tool always remains at the Set temperature outside the holder.

The holder function is activated when the soldering tool is placed in the holder for the first time.

Note

Note

Reset of STANDBY and AUTO OFF modes:

without switching holder, by depressing the UP or DOWN Scroll Keys.

with switching holder, by removing the soldering tool from the holder.

Setting the Temperature Offset

The Read soldering-tip temperature can be adjusted by entering a temperature offset ± 72 °F ( ± 40 °C ).

1.Select the menu item OFFSET in Menu 1.

2.Set the OFFSET temperature value with the UP or DOWN Scroll Key.

3.Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Setting the Window Function

It is possible, starting from a Set, Locked temperature, to set a temperature range of ± 180 °F ( ± 99 °C ) with the WINDOW function. The temperature range (Window) must be Set prior to Locking the station.

To be able to use the WINDOW function, make sure the Rework Station is in the Locked mode (see "Switching the lock function on/off“ Page 10).

1.Select the menu item WINDOW in Menu 1.

2.Set the WINDOW temperature value with the UP or DOWN Scroll Key.

3.Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Switching the Temperature Display

Switching the temperature display from °F to °C or vice versa.

1.Select the temperature display °F / °C in Menu 1.

2.Set the temperature display with the UP or DOWN Scroll Key.

4.Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Limiting the Time (HAP ON) time for Hot-Air Pencil

With the HAP-Ontime for the Hot Air Pencil, hot-air flow can be limited in increments of 1, from 0 to 60 seconds. The set time is then identical for all 3 channels. Factory setting is 0 seconds ("OFF“), i.e.

Image 12
Contents Buttons 1 , 2 Button 1·2·3Air Receptacle 1 , 2Table of Contents InstructionsSafety Information Packing ListDescription Tools and Holders DXV 80 WR3000MWP 80 WR3000M WR 3M Technical Data USB PortInitial Set-up Connected to the air portSelecting a channel, switching on or OFF Setting the TemperatureOperating Guidelines Setting the Air Flow Setting the Pre-set Temperature on Radio Buttons 1 , 2 orTemperature Setting using the Radio Buttons 1 , 2 or Switching the Vacuum Pick-up Pump ON/OFF Special FunctionsSoldering and Desoldering Selecting Menu 1 Special FunctionsSetting the Standby Temperature Possibility of manual temperature reduction Setback whenSetback Time Soldering / desoldering tool is not in useSetting the Automatic Switch-Off Time AUTO-OFF Settings Tool Operation without Switching HolderTool Operation with Switching Holder OFF functionsSetting the Window Function Switching the Temperature DisplayLimiting the Time HAP on time for Hot-Air Pencil Setting the Vacuum OFF delay VAC OFF Setting the Vacuum on delay VAC onSwitching the Lock Function On/Off Depressing the Radio buttons 1 or 2 while OFF is displayedResetting the Special Functions to Factory Default Settings Setting the Station Identification Remote ID codeSelecting Menu 2 Special Functions Special Functions NavigationChanges Exit Factory Control Check FCCControl Check at 212 F / 100 C Depress Radio Button 3 to exit the menu item without savingSetting the Pick-Up Vacuum Level Maintaining and Servicing the WR 3MChanging the Filter Fault Indications and Correction Indication/symptom Possible cause Corrective ActionAccessories Warranty DisposalWR 3M XX XXX XX / 03.07 2007 Cooper Industries