Cooper Lighting Setting the Air Flow, Temperature Setting using the Radio Buttons 1 , 2 or

Page 8

Page 8 of 21

WR 3M

2.Depress the UP or DOWN Scroll Key. The display switches to the set value. The temperature symbol (18) flashes.

3.Depress the UP or DOWN Scroll Key to set the desired temperature:

-Tapping the Scroll Keys changes the Set temperature by one degree.

-Holding down the Scroll Keys changes the Set temperature rapidly.

The Set value of the selected channel appears in the display for approximately 2 seconds after the Scroll Keys are released.

Setting the Pre-set Temperature on Radio Buttons ┌ 1 ┐,┌ 2 ┐ or ┌ 3

The temperature can be set for each channel separately by selecting three fixed/pre-set Radio Buttons.

1.Select a channel.

Three fixed/pre-set temperatures are shown in the display for approximately 2 seconds. The temperature can now be Set as long as the temperature symbol is flashing.

2.Adjust the temperature in the large display with the UP or DOWN Scroll Keys.

3.Depress the desired Radio Button ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐ for 3 seconds. The temperature display for the corresponding temperature value flashes during this period. The Set value is stored after 3 seconds.

4.Release the Radio Button.

Temperature Setting using the Radio Buttons ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐

Factory default settings:

1 ┐ = 300 °F ( 150 °C ),

2 ┐ = 660 °F ( 350 °C ),

3 ┐ = 720 °F ( 380 °C )

1. Select a channel.

Three fixed/pre-set temperatures are shown in the display for approximately 2 seconds. The temperature can now be Set as long as the temperature symbol is flashing.

2.The desired fixed/pre-set temperature can now be selected with Radio Buttons ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐

3.The Set value is adopted. The Read temperature of the selected channel is displayed after 3 seconds.

6.3Setting the Air Flow

The Air Flow can, starting from a maximum flow value of 15 l/s (HAP

200)or 10 l/s (HAP 1), be adjusted between 10% to 100%. 1. Depress the AIR button.

Image 8
Contents Buttons 1 , 2 Button 1·2·3Air Receptacle 1 , 2Table of Contents InstructionsDescription Safety InformationPacking List WP 80 WR3000M Tools and HoldersDXV 80 WR3000M WR 3M Technical Data USB PortInitial Set-up Connected to the air portOperating Guidelines Selecting a channel, switching on or OFFSetting the Temperature Temperature Setting using the Radio Buttons 1 , 2 or Setting the Air FlowSetting the Pre-set Temperature on Radio Buttons 1 , 2 or Switching the Vacuum Pick-up Pump ON/OFF Special FunctionsSoldering and Desoldering Selecting Menu 1 Special FunctionsSetting the Standby Temperature Possibility of manual temperature reduction Setback whenSetback Time Soldering / desoldering tool is not in useSetting the Automatic Switch-Off Time AUTO-OFF Settings Tool Operation without Switching HolderTool Operation with Switching Holder OFF functionsLimiting the Time HAP on time for Hot-Air Pencil Setting the Window FunctionSwitching the Temperature Display Setting the Vacuum OFF delay VAC OFF Setting the Vacuum on delay VAC onSwitching the Lock Function On/Off Depressing the Radio buttons 1 or 2 while OFF is displayedResetting the Special Functions to Factory Default Settings Setting the Station Identification Remote ID codeSelecting Menu 2 Special Functions Special Functions NavigationChanges Exit Factory Control Check FCCControl Check at 212 F / 100 C Depress Radio Button 3 to exit the menu item without savingChanging the Filter Setting the Pick-Up Vacuum LevelMaintaining and Servicing the WR 3M Fault Indications and Correction Indication/symptom Possible cause Corrective ActionAccessories Warranty DisposalWR 3M XX XXX XX / 03.07 2007 Cooper Industries