Intel GD82559ER manual PCI Timings, Flash Interface Timings, PCI Timing Parameters

Page 85

Networking Silicon — GD82559ER

Table 24. Measure and Test Condition Parameters

Vstep (rising edge)

0.285VCC

0.325VCC

V

Min Delay

0.475VCC

V

Max Delay

 

 

Vstep (falling edge)

0.615VCC

0.475VCC

V

Min Delay

0.325VCC

V

Max Delay

 

 

Vmax

0.4VCC

0.4VCC

V

 

Input Signal Edge

1

1

V/ns

 

Rate

 

 

 

 

 

 

 

 

 

 

NOTE: Input test is done with 0.1VCC overdrive. Vmax specifies the maximum peak-to-peak waveform allowed for testing input timing.

10.4.2.2PCI Timings

Table 25. PCI Timing Parameters

 

Symbol

Parameter

Min

Max

Units

Notes

 

 

 

 

 

 

 

T14

tval

PCI CLK to Signal Valid Delay

2

11

ns

1, 2, 4

T15

tval(ptp)

PCI CLK to Signal Valid Delay (point-

2

12

ns

1, 2, 4

to-point)

T16

ton

Float to Active Delay

2

 

ns

1

T17

toff

Active to Float Delay

 

28

ns

1

T18

tsu

Input Setup Time to CLK

7

 

ns

4, 5

T19

tsu(ptp)

PCI Input Setup Time to CLK (point-to-

10

 

ns

4, 5

point)

 

T20

th

Input Hold Time from CLK

0

 

ns

6

T21

trst

Reset Active Time After Power Stable

1

 

ms

6

T22

Trst-clk

PCI Reset Active Time After CLK

100

 

μs

6

Stable

 

T23

Trst-off

Reset Active to Output Float Delay

 

40

ns

6, 7

NOTES:

1.Timing measurement conditions are illustrated in Figure 27.

2.PCI minimum times are specified with loads as detailed in the PCI Bus Specification, Revision 2.1, Section 4.2.3.2.

3.n a PCI environment, REQ# and GNT# are point-to-point signals and have different output valid delay times and input setup times than bussed signals. All other signals are bussed.

4.Timing measurement conditions are illustrated in Figure 28.

5.RST# is asserted and de-asserted asynchronously with respect to the CLK signal.

6.All PCI interface output drivers are floated when RST# is active.

10.4.2.3Flash Interface Timings

The 82559ER is designed to support up to 150 nanoseconds of Flash access time. The VPP signal in the Flash implementation should be connected permanently to 12 V. Thus, writing to the Flash is controlled only by the FLWE# pin.

Table 26 provides the timing parameters for the Flash interface signals. The timing parameters are illustrated in Figure 29.

Datasheet

79

Image 85
Contents GD82559ER Fast Ethernet PCI Controller Product FeaturesMar First release Revision DescriptionContents PCI Configuration Registers Electrical and Timing Specifications GD82559ER Networking Silicon Datasheet GD82559ER Overview IntroductionSuggested Reading GD82559ER Networkin g Silicon Datasheet Parallel Subsystem Overview GD82559ER Architectural OverviewGD82559ER Networkin g Silicon Fifo Subsystem Overview10/100 Mbps Physical Layer Unit 10/100 Mbps Serial CSMA/CD Unit OverviewGD82559ER Networkin g Silicon Datasheet Signal Type Definitions Signal DescriptionsPCI Bus Interface Signals Address and Data SignalsInterface Control Signals System and Power Management Signals Local Memory Interface SignalsTestability Port Signals PHY Signals GD82559ER Networkin g Silicon Datasheet 82559ER Initialization GD82559ER Media Access Control Functional DescriptionInitialization Effects on 82559ER Units D3 to D0 Software SelectivePCI Interface Control/Status Register CSR Accesses1 82559ER Bus Operations 1.1 82559ER Bus Slave OperationCSR I/O Read Cycle Flash Buffer Read Cycle Flash Buffer AccessesFlash Buffer Write Cycle Retry Premature Accesses1.2 82559ER Bus Master Operation Error HandlingMemory Read Burst Cycle Memory Write and Invalidate Read Align Power Management Event Signal Clockrun Signal4.1 D0 Power State Power States4.2 D1 Power State 4.3 D2 Power StateUnderstanding Power Requirements 4.4 D3 Power StatePower State Conditions 100 Mbs 10 Mbs PCI CLKAlternate Reset Signal Auxiliary Power SignalIsolate Signal Power State Link 82559ER FunctionalityIsolate Signal Behavior to PCI Power Good Signal PCI Reset SignalInterestin g Packet Events Wake-up EventsSerial Eeprom Interface Parallel Flash InterfaceLink Status Change Event Subsystem ID Word IA ByteEeprom Words Field Descriptions 10/100 Mbps CSMA/CD UnitBits Name Description ALLFlow Control Full DuplexAddress Filtering Modifications Long Frame ReceptionMedia Independent Interface MII Management Interface GD82559ER Test Port Functionality Asynchronous Test ModeIntroduction Test Function DescriptionNand Tree TriStateNand Tree Chains Chain OrderFLD6 STOP# FLD2 GNT# FLD3 PERR# FLD4 PAR FLD5FLD7 AD9GD82559ER Networkin g Silicon Datasheet 100BASE-TX PHY Unit GD82559ER Physical Layer Functional Description1 100BASE-TX Transmit Clock Generation 2 100BASE-TX Transmit BlocksInvalid 2.2 100BASE-TX Scrambler and MLT-3 EncoderTransmit Driver 2.3 100BASE-TX Transmit FramingMagnetics Modules Vendor Model/Type3 100BASE-TX Receive Blocks 10BASE-T Functionality 5 100BASE-TX Link Integrity and Auto-Negotiation Solution4 100BASE-TX Collision Detection Auto 10/100 Mbps Speed Selection3 10BASE-T Receive Blocks 2 10BASE-T Transmit Blocks2.1 10BASE-T Manchester Encoder 2.2 10BASE-T Driver and Filter4 10BASE-T Collision Detection Auto-Negotiation Functionality5 10BASE-T Link Integrity 6 10BASE-T Jabber Control FunctionParallel Detect and Auto-Negotiation DescriptionAuto-Negotiation and Parallel Detect LED DescriptionLiled T L E D Two and Three LED Schematic DiagramLAN Ethernet PCI Configuration Space PCI Configuration RegistersPCI Vendor ID and Device ID Registers PCI Command Register PCI Command Register Bits PCI Command RegisterPCI Status Register PCI Status Register Bits PCI Status RegisterPCI Class Code Register PCI Revision ID RegisterPCI Cache Line Size Register PCI Header Type PCI Latency TimerPCI Base Address Registers CSR I/O Mapped Base Address Register CSR Memory Mapped Base Address RegisterFlash Memory Mapped Base Address Register Expansion ROM Base Address RegisterCapability Pointer PCI Subsystem Vendor ID and Subsystem ID RegistersInterrupt Line Register ER ID Fields ProgrammingInterrupt Pin Register Power Management Capabilities RegisterMinimum Grant Register Maximum Latency RegisterPower Management Control and Status Register Power Management Control/Status Register PmcsrEthernet Data Register Data RegisterData Select Data Scale Data Reported LAN Ethernet Control/Status Registers Control/Status RegistersD31 D16 D15 Lower Word OffsetSystem Control Block Status Word System Control Block General Pointer System Control Block Command WordPort Flash Control RegisterPower Management Driver Register Receive Direct Memory Access Byte CountPower Management Driver Register Early Receive InterruptGeneral Status Register General Control RegisterGeneral Control Register General Status RegisterER Statistical Counters Statistical CountersCounter Description Frame indicator, they are not counted GD82559ER Networking Silicon Datasheet PHY Unit Registers Bits Name Description DefaultMDI Registers 0 Register 0 Control Register Bit DefinitionsRegister 1 Status Register Bit Definitions Register 2 PHY Identifier Register Bit Definitions Bits Name Description Default 150Register 3 PHY Identifier Register Bit Definitions Value 0154HMDI Register 16 MDI Registers 8100BASE-TX 10BASE-TRegister 17 PHY Unit Special Control Bit Definitions Register 18 PHY Address Register Register 22 Receive Symbol Error Counter Bit DefinitionsBits Counter Bit Definitions Register 23 100BASE-TX Receive Premature End of Frame ErrorRegister 26 Equalizer Control and Status Bit Definitions Register 27 PHY Unit Special Control Bit DefinitionsGD82559ER Networking Silicon Datasheet DC Specifications Electrical and Timing SpecificationsGeneral DC Specifications PCI Interface DC SpecificationsLED Voltage/Current Characteristics Flash/EEPROM Interface DC SpecificationsBASE-TX Voltage/Current Characteristics Symbol Parameter BASE-T Voltage/Current CharacteristicsVCC/2 AC Specifications for PCI Signaling AC SpecificationsClocks Specifications Timing SpecificationsPCI Clock Specifications 10.4.1.2 X1 SpecificationsTiming Parameters Symbol PCI Level UnitsMeasurement and Test Conditions PCI Timings Symbol Parameter Min Max UnitsFlash Interface Timings PCI Timing ParametersFlash Timing Parameters Eeprom Timing Parameters Eeprom Interface TimingsSymbol Parameter Min Typ Max Symbol Parameter Condition Min Typ Max UnitsPHY Timings BASE-T NLP Timing ParametersTDP/TDN Differential HLS Data 1400 Output Peak Jitter Symbol Parameter Condition Min Typ Max Units T64GD82559ER Networking Silicon Datasheet Package Information Package and Pinout Information12.2.1 GD82559ER Pin Assignments Pinout InformationGD82559ER Pin Assignments Pin NamePERR# GNT# VCC STOP# INTA# DEVSEL# VCC VSSFLA1 FLA0GD82559ER Ball Grid Array Diagram 12.2.2 GD82559ER Ball Grid Array Diagram

GD82559ER specifications

The Intel GD82559ER is a highly regarded network interface controller (NIC) designed for use in various computing environments, primarily for stable connectivity in both desktop and server applications. Released as part of the 82559 family of Ethernet controllers, the GD82559ER features advanced technologies that enhance performance, reliability, and manageability.

One of the standout features of the 82559ER is its ability to support both 10/100 Mbps Ethernet. This dual capability allows the controller to operate in a wide range of network settings, making it adaptable to legacy systems while also providing support for modern Ethernet standards. This versatility is crucial for organizations looking to maintain operational effectiveness without the need for immediate upgrades to their existing infrastructure.

The GD82559ER employs a PCI interface, which allows it to connect with various devices and motherboards easily, making it a go-to choice for manufacturers aiming for integration in their systems. It also includes features like Auto-Negotiation, enabling the NIC to automatically detect and select the appropriate speed and duplex mode for optimal performance. This capability is essential in dynamic networking environments, where devices from various generations coexist.

Power management is another critical aspect of the GD82559ER. The controller supports advanced power-saving features like PCI Power Management, reducing energy consumption during low-usage periods. This not only contributes to lower operational costs but also aligns with modern eco-friendly initiatives in technology.

Additionally, the GD82559ER comes equipped with advanced diagnostics and monitoring capabilities. This enhances the network's manageability by allowing administrators to track performance metrics and diagnose issues effectively. Through its onboard diagnostics, the controller aids in ensuring a stable network connection, allowing for timely interventions when issues arise.

The controller is also designed with a robust architecture that supports various operating systems, facilitating a broad implementation across different platforms. As a result, the GD82559ER has become a reliable option for system builders and enterprises focused on building dependable networking solutions.

Overall, the Intel GD82559ER is a versatile, high-performance network interface controller that continues to serve as a foundational component for computer systems that require efficient, reliable networking capabilities. Its combination of technologies and features makes it a popular choice in diverse computing environments.