Hitachi SJ-PB(T) instruction manual Hitachi Inverter

Page 1

Hitachi Inverter

SJ300/L300P SERIES

SJ-PB(T)(Profibus-DP Option)

INSTRUCTION MANUAL

Thank you for purchase of “HITACHI INVERTER”. This manual explains about treatment of “SJ-PB(T) (Profibus-DP Option)”. By reading this manual and an instruction manual of inverter use practically for installation, maintenance, and inspection. After reading this manual, keep it handy for future reference.

Make sure to reach this manual to the end user.

 

Table of Contents

 

Chapter1

INTRODUCTION

1

Chapter2

INSTALLATION

5

Chapter3

WIRING, CONNECTING

6

Chapter4

SETTING

8

Chapter5

OPERATING

10

Chapter6

COUNTERMASURE FOR ABNORMALIT

21

Appendix

PARAMETER CROSS-REFERENCE LIST

22

After reading this manual, keep it at handy for future reference.

NB622BX

Image 1
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of electric shock and/or fire Otherwise, there is a danger of connecting errorOtherwise, there is a danger of electric shock Otherwise, there is a danger of fireInspection Upon Unpacking Appearance and Names of Parts Outline of productProfibus-DP Supported Version Technical features of Profibus-DPApplication temperature 0 to 50 degree Production specificationMounting method of option board Installation of option boardPhysical interface Profibus connectorsPin Layout of SJ-PB Name Function Pin Layout of SJ-PBTPROFIBUS-DP Wiring noteNode Address Profibus ConfigurationBaudrate PPO-type selectionAction at communication error Setting of controlling frequency and start/stop commandsP001/P002 Action at error detection Remarks Operating PPO- descriptionPCA word PKW-partResponse ID Function Request Function Ackn +Control- / status word STW/ZSW PZD-partStatus word Frequency set-point/ Actual frequency Profidrive state diagramPlease Note PZD wordWriting a four byte parameter Parameter ExamplesWriting a two byte array parameter Writing a two byte array parameter #2 Profidrive parameters Profidrive specific parametersMalfunction codes Fault code SJ300/L300P Fault description ParameterProtection function list Trip displayCountermeasure for a trip state LED display and CountermeasureParameter cross-reference list Code Size Range Magn Contents L300P ReadCode Size Range Magn H033 ~655.35A 100 1st No load current Io of motor Auto B023 126 10~30.00 100 Constant value of Overload restriction C111 169 ~200.0% Level2 of overload restriction warning A053 215 ~5.0s Delay time of DC braking start B045 252 00,01 Code Selection of LAD stop by torque Appendix P013 329 00~03 Code Selection of method of Pulse lines input Code Size