Hitachi SJ-PB(T) instruction manual Code Size

Page 35

 

 

 

 

 

APPENDIX

PARAMETER CROSS-REFERENCE LIST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

No.

Size

Range

Magn.

 

Contents

L300P

Read/

 

 

 

Write

 

 

 

 

 

 

 

 

 

 

 

 

d084

376

2

01000.0V

*10

PN voltage (DC voltage) of Trip4

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

d084

377

4

0

*1

Accumulated time during running

 

RO

 

 

4294836225s

 

of Trip4

 

 

 

 

 

 

 

 

 

 

 

 

d084

378

4

0

*1

Accumulated time during power ON

 

RO

 

 

4294836225s

 

of Trip4

 

 

 

 

 

 

 

 

 

 

 

 

d085

379

4

00H'FF

*1

 

Factor and Status of Trip5

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d085

380

4

0400.00Hz

*100

 

Frequency of Trip5

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d085

381

2

01000.0A

*10

 

Output current of Trip5

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

d085

382

2

01000.0V

*10

PN voltage (DC voltage) of Trip5

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

d085

383

4

0

*1

Accumulated time during running

 

RO

 

 

4294836225s

 

of Trip5

 

 

 

 

 

 

 

 

 

 

 

 

d085

384

4

0

*1

Accumulated time during power ON

 

RO

 

 

4294836225s

 

of Trip5

 

 

 

 

 

 

 

 

 

 

 

 

d086

385

4

00H'FF

*1

 

Factor and Status of Trip6

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d086

386

4

0400.00Hz

*100

 

Frequency of Trip6

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d086

387

2

01000.0A

*10

 

Output current of Trip6

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

d086

388

2

01000.0V

*10

PN voltage (DC voltage) of Trip6

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

d086

389

4

0

*1

Accumulated time during running

 

RO

 

 

4294836225s

 

of Trip6

 

 

 

 

 

 

 

 

 

 

 

 

d086

390

4

0

*1

Accumulated time during power ON

 

RO

 

 

4294836225s

 

of Trip6

 

 

 

 

 

 

 

 

 

 

 

 

-

392

1

0002

code

Selection of Area code of inverter

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

-

393

1

0115

code

Selection of Capacity code of inverter

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

-

394

1

00,01

code

Selection of Voltage of inverter

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

-

395

1

00,01

code

Selection of Changeover of inverter mode

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d001

397

4

0400.000Hz

*1000

 

Output frequency

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

d004

398

4

0400.000Hz

*1000

Feedback data of PID control

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

d007

399

4

039960.000

*1000

Value of conversion of frequency

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

d101

400

4

0400.000Hz

*1000

Output frequency after Vector control

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d016

401

4

0

*1

Accumulated time during running

 

RO

 

 

4294836225s

 

 

 

 

 

 

 

 

 

 

 

 

 

d017

402

4

0

*1

Accumulated time during Power ON

 

RO

 

 

4294836225s

 

 

 

 

 

 

 

 

 

 

 

 

 

-

403

4

0400.000Hz

*1000

Setting frequency from terminal

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

-

404

4

0400.000Hz

*1000

 

Setting frequency from

 

RO

 

 

 

attached potentiometer

 

 

 

 

 

 

 

 

 

 

 

 

 

-

405

4

0400.000Hz

*1000

Setting frequency from digital operator

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d002

407

2

01000.0A

*10

 

Output current

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d005

408

2

0H'FFFF

bit

 

Status of Input terminal

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d012

409

2

-300+300%

*1

 

Output Torque

No

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d014

410

2

01000.0kW

*10

 

Input electric power

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

412

2

01000.0V

*10

 

DC voltage

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

413

2

0100.0s

*10

 

On time of BRD running

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

414

2

0100.0%

*10

Used rate of electronics thermal protection

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d006

416

2

0H'FFFF

bit

 

Status of output terminal

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d013

417

2

01000.0V

*10

 

Output voltage

 

RO

 

 

 

 

 

 

 

 

 

 

 

 

 

d003

418

1

0002

code

 

Direction of present running

 

RO

 

 

 

 

 

 

 

 

 

 

 

R/W: Parameter is read/writable.

R/WOS: Parameter is readable, but can only be written when the inverter is stopped.

R/O: Parameter is read-only. Cannot be written.

31

Image 35
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of fire Otherwise, there is a danger of connecting errorOtherwise, there is a danger of electric shock and/or fire Otherwise, there is a danger of electric shockInspection Upon Unpacking Appearance and Names of Parts Outline of productProfibus-DP Supported Version Technical features of Profibus-DPApplication temperature 0 to 50 degree Production specificationMounting method of option board Installation of option boardPin Layout of SJ-PBT Profibus connectorsPhysical interface Pin Layout of SJ-PB Name FunctionPROFIBUS-DP Wiring notePPO-type selection Profibus ConfigurationNode Address BaudrateP001/P002 Action at error detection Remarks Setting of controlling frequency and start/stop commandsAction at communication error Operating PPO- descriptionPCA word PKW-partResponse ID Function Request Function Ackn +Control- / status word STW/ZSW PZD-partStatus word Frequency set-point/ Actual frequency Profidrive state diagramPlease Note PZD wordWriting a two byte array parameter Parameter ExamplesWriting a four byte parameter Writing a two byte array parameter #2 Profidrive parameters Profidrive specific parametersMalfunction codes Fault code SJ300/L300P Fault description ParameterLED display and Countermeasure Trip displayProtection function list Countermeasure for a trip stateParameter cross-reference list Code Size Range Magn Contents L300P ReadCode Size Range Magn H033 ~655.35A 100 1st No load current Io of motor Auto B023 126 10~30.00 100 Constant value of Overload restriction C111 169 ~200.0% Level2 of overload restriction warning A053 215 ~5.0s Delay time of DC braking start B045 252 00,01 Code Selection of LAD stop by torque Appendix P013 329 00~03 Code Selection of method of Pulse lines input Code Size