Hitachi SJ-PB(T) instruction manual H033 ~655.35A 100 1st No load current Io of motor Auto

Page 28

APPENDIX PARAMETER CROSS-REFERENCE LIST

Code

No.

Size

Range

Magn.

Contents

L300P

Read/

Write

 

 

 

 

 

 

 

H033

82

4

0655.35A

*100

1st No load current Io of motor (Auto)

No

R/WOS

 

 

 

 

 

 

 

 

H233

83

4

0655.35A

*100

2nd No load current Io of motor (Auto)

No

R/WOS

 

 

 

 

 

 

 

 

H034

84

4

0.001

*100

1st Inertia J of motor (Auto)

No

R/WOS

9999.000kgm2

 

 

 

 

 

 

 

H234

85

4

0.001

*100

2nd Inertia J of motor (Auto)

No

R/WOS

9999.000kgm2

 

 

 

 

 

 

 

A043

86

2

050.0%

*10

1st Break point of manual torque boost

 

R/W

 

 

 

 

 

 

 

 

A243

87

2

050.0%

*10

2nd Break point of manual torque boost

 

R/W

 

 

 

 

 

 

 

 

A343

88

2

050.0%

*10

3rd Break point of manual torque boost

No

R/W

 

 

 

 

 

 

 

 

A052

89

2

060.00Hz

*100

Frequency of DC braking start

 

R/WOS

 

 

 

 

 

 

 

 

A055

90

2

060.0s

*10

Time of DC braking working

 

R/WOS

 

 

 

 

 

 

 

 

A058

91

2

060.0s

*10

Time of DC braking working

 

R/WOS

for beginning of inverter running

 

 

 

 

 

 

 

 

A064

92

2

010.00Hz

*100

Width of jumping frequency 1

 

R/WOS

 

 

 

 

 

 

 

 

A066

93

2

010.00Hz

*100

Width of jumping frequency 2

 

R/WOS

 

 

 

 

 

 

 

 

A068

94

2

010.00Hz

*100

Width of jumping frequency 3

 

R/WOS

 

 

 

 

 

 

 

 

A070

95

2

060.0s

*10

Time of stopping to accelerate

 

R/WOS

 

 

 

 

 

 

 

 

A073

96

2

03600.0s

*10

Integrate (I) gain of PID control

 

R/W

 

 

 

 

 

 

 

 

A074

97

2

0100.00

*100

Differential (D) gain of PID control

 

R/W

 

 

 

 

 

 

 

 

A075

98

2

0.0199.99%

*100

Scale of PID control

 

R/WOS

 

 

 

 

 

 

 

 

A086

99

2

0100.0

*10

Response time of Energy saving function

 

R/W

 

 

 

 

 

 

 

 

b003

101

2

0.3100.0s

*10

Waiting time of retry

 

R/WOS

 

 

 

 

 

 

 

 

b012

102

2

20.0120.0

*10

Level of 1st Electronic thermal protection

 

R/WOS

 

 

 

 

 

 

 

 

b212

103

2

20.0120.0

*10

Level of 2nd Electronic thermal protection

 

R/WOS

 

 

 

 

 

 

 

 

b312

104

2

20.0120.0

*10

Level of 3rd Electronic thermal protection

No

R/WOS

 

 

 

 

 

 

 

 

b015

105

2

0400Hz

*1

Free electronic thermal frequency 1

 

R/WOS

 

 

 

 

 

 

 

 

b016

106

2

01000.0A

*10

Free electronic thermal current 1

 

R/WOS

 

 

 

 

 

 

 

 

b017

107

2

0400Hz

*1

Free electronic thermal frequency 2

 

R/WOS

 

 

 

 

 

 

 

 

b018

108

2

01000.0A

*10

Free electronic thermal current 2

 

R/WOS

 

 

 

 

 

 

 

 

b019

109

2

0400Hz

*1

Free electronic thermal frequency 3

 

R/WOS

 

 

 

 

 

 

 

 

b020

110

2

01000.0A

*10

Free electronic thermal current 3

 

R/WOS

 

 

 

 

 

 

 

 

b100

111

2

0400Hz

*1

Free V/F control frequency 1

 

R/WOS

 

 

 

 

 

 

 

 

b101

112

2

0.0800.0V

*10

Free V/F control voltage 1

 

R/WOS

 

 

 

 

 

 

 

 

b102

113

2

0400Hz

*1

Free V/F control frequency 2

 

R/WOS

 

 

 

 

 

 

 

 

b103

114

2

0.0800.0V

*10

Free V/F control voltage 2

 

R/WOS

 

 

 

 

 

 

 

 

b104

115

2

0400Hz

*1

Free V/F control frequency 3

 

R/WOS

 

 

 

 

 

 

 

 

b105

116

2

0.0800.0V

*10

Free V/F control voltage 3

 

R/WOS

 

 

 

 

 

 

 

 

b106

117

2

0400Hz

*1

Free V/F control frequency 4

 

R/WOS

 

 

 

 

 

 

 

 

b107

118

2

0.0800.0V

*10

Free V/F control voltage 4

 

R/WOS

 

 

 

 

 

 

 

 

b108

119

2

0400Hz

*1

Free V/F control frequency 5

 

R/WOS

 

 

 

 

 

 

 

 

b109

120

2

0.0800.0V

*10

Free V/F control voltage 5

 

R/WOS

 

 

 

 

 

 

 

 

b110

121

2

0400Hz

*1

Free V/F control frequency 6

 

R/WOS

 

 

 

 

 

 

 

 

b111

122

2

0.0800.0V

*10

Free V/F control voltage 6

 

R/WOS

 

 

 

 

 

 

 

 

b112

123

2

0400Hz

*1

Free V/F control frequency 7

 

R/WOS

 

 

 

 

 

 

 

 

b113

124

2

0.0800.0V

*10

Free V/F control voltage 7

 

R/WOS

 

 

 

 

 

 

 

 

b022

125

2

50.0200.0

*10

Level of Overload restriction 1

50.0

R/WOS

150.0

 

 

 

 

 

 

 

24

Image 28
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of connecting error Otherwise, there is a danger of electric shock and/or fireOtherwise, there is a danger of electric shock Otherwise, there is a danger of fireInspection Upon Unpacking Outline of product Appearance and Names of PartsTechnical features of Profibus-DP Profibus-DP Supported VersionProduction specification Application temperature 0 to 50 degreeInstallation of option board Mounting method of option boardProfibus connectors Physical interfacePin Layout of SJ-PB Name Function Pin Layout of SJ-PBTWiring note PROFIBUS-DPProfibus Configuration Node AddressBaudrate PPO-type selectionAction at communication error Setting of controlling frequency and start/stop commandsP001/P002 Action at error detection Remarks PPO- description OperatingPKW-part PCA wordRequest Function Ackn + Response ID FunctionPZD-part Control- / status word STW/ZSWStatus word Profidrive state diagram Frequency set-point/ Actual frequencyPZD word Please NoteWriting a four byte parameter Parameter ExamplesWriting a two byte array parameter Writing a two byte array parameter #2 Profidrive specific parameters Profidrive parametersFault code SJ300/L300P Fault description Parameter Malfunction codesTrip display Protection function listCountermeasure for a trip state LED display and CountermeasureCode Size Range Magn Contents L300P Read Parameter cross-reference listCode Size Range Magn H033 ~655.35A 100 1st No load current Io of motor Auto B023 126 10~30.00 100 Constant value of Overload restriction C111 169 ~200.0% Level2 of overload restriction warning A053 215 ~5.0s Delay time of DC braking start B045 252 00,01 Code Selection of LAD stop by torque Appendix P013 329 00~03 Code Selection of method of Pulse lines input Code Size