Hitachi SJ-PB(T) Malfunction codes, Fault code SJ300/L300P Fault description Parameter

Page 24

CHAPTER5 OPERATING

The malfunction codes are coded as follows.

 

Table5- 2 Malfunction codes

Fault code SJ300/L300P

 

Fault description

parameter 947

 

 

0

 

No fault

1

 

Overcurrent inverter.

2

 

Overcurrent deceleration.

3

 

Overcurrent acceleration.

4

 

Overcurrent.

5

 

Overload protection.

6

 

Braking resistor overload protection.

7

 

Over-voltage protection.

8

 

EEPROM error.

9

 

Under-voltage.

10

 

Current detector error.

11

 

CPU error.

12

 

External trip.

13

 

USP error.

14

 

Ground fault protection.

15

 

Incoming over-voltage protection.

16

 

Temporary power loss protection.

21

 

Abnormal temperature.

23

 

Gate allay error.

24

 

Open-phase error.

30

 

IGBT error.

35

 

Thermistor error.

36

 

Abnormal brake.

60-69

 

Option 1 error 0-9.

70-79

 

Option 2 error 0-9.

20

Image 24
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of connecting error Otherwise, there is a danger of electric shock and/or fireOtherwise, there is a danger of electric shock Otherwise, there is a danger of fireInspection Upon Unpacking Outline of product Appearance and Names of PartsTechnical features of Profibus-DP Profibus-DP Supported VersionProduction specification Application temperature 0 to 50 degreeInstallation of option board Mounting method of option boardProfibus connectors Physical interfacePin Layout of SJ-PB Name Function Pin Layout of SJ-PBTWiring note PROFIBUS-DPProfibus Configuration Node AddressBaudrate PPO-type selectionSetting of controlling frequency and start/stop commands Action at communication errorP001/P002 Action at error detection Remarks PPO- description OperatingPKW-part PCA wordRequest Function Ackn + Response ID FunctionPZD-part Control- / status word STW/ZSWStatus word Profidrive state diagram Frequency set-point/ Actual frequencyPZD word Please NoteParameter Examples Writing a four byte parameterWriting a two byte array parameter Writing a two byte array parameter #2 Profidrive specific parameters Profidrive parametersFault code SJ300/L300P Fault description Parameter Malfunction codesTrip display Protection function listCountermeasure for a trip state LED display and CountermeasureCode Size Range Magn Contents L300P Read Parameter cross-reference listCode Size Range Magn H033 ~655.35A 100 1st No load current Io of motor Auto B023 126 10~30.00 100 Constant value of Overload restriction C111 169 ~200.0% Level2 of overload restriction warning A053 215 ~5.0s Delay time of DC braking start B045 252 00,01 Code Selection of LAD stop by torque Appendix P013 329 00~03 Code Selection of method of Pulse lines input Code Size