Hitachi SJ-PB(T) instruction manual Revision History Table

Page 2

- Request -

Thank you for purchase of “SJ-PB(T) (Profibus-DP Option)”.

This instruction manual explains about treatment and maintenance of “SJ-PB(T)”. Before using the product, carefully read this manual with the instruction manual of inverter, and keeps it handy for quick reference of operator and maintenance inspector. Before installing, operating, maintenance and inspection read this manual carefully and follow the instructions exactly.

Always keep various kinds of specification mentioned in this manual and use exactly. And make sure to prevent trouble by correct inspection and maintenance. Make sure to reach this manual to the end user.

- About treatment of this manual -

(1)Please consent that mentioned items of this manual may be change without permission. (2)Keep this manual carefully not to lose because it can not be reissued

(3)All right reserved.

(4)Contents in this manual is written to make assurance doubly sure but, but please contact if you have some doubts about spelling mistakes, omitted word etc.

(5)Please agree that there is no responsibility for effects resulted, in spite of contents above mentioned.

- About trademark -

(1)Profibus is registered trademark of Profibus Nutzerorganisation.

Revision History Table

No.

Revision contents

The date of issued

Manual No.

1.

Initial release of Manual NB622X

May. 2001

NB622X

2.

Looking at again details.

Oct. 2001

NB622AX

3.

Adding mention of SJ-PBT. Looking at again details.

June. 2002

NB622BX

 

 

 

 

Except this table, revised only spelling mistakes omitted words, and error writings without notice.

Image 2
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of electric shock Otherwise, there is a danger of connecting errorOtherwise, there is a danger of electric shock and/or fire Otherwise, there is a danger of fireInspection Upon Unpacking Outline of product Appearance and Names of PartsTechnical features of Profibus-DP Profibus-DP Supported VersionProduction specification Application temperature 0 to 50 degreeInstallation of option board Mounting method of option boardPin Layout of SJ-PB Name Function Profibus connectorsPhysical interface Pin Layout of SJ-PBTWiring note PROFIBUS-DPBaudrate Profibus ConfigurationNode Address PPO-type selectionP001/P002 Action at error detection Remarks Setting of controlling frequency and start/stop commandsAction at communication error PPO- description OperatingPKW-part PCA wordRequest Function Ackn + Response ID FunctionPZD-part Control- / status word STW/ZSWStatus word Profidrive state diagram Frequency set-point/ Actual frequencyPZD word Please NoteWriting a two byte array parameter Parameter ExamplesWriting a four byte parameter Writing a two byte array parameter #2 Profidrive specific parameters Profidrive parametersFault code SJ300/L300P Fault description Parameter Malfunction codesCountermeasure for a trip state Trip displayProtection function list LED display and CountermeasureCode Size Range Magn Contents L300P Read Parameter cross-reference listCode Size Range Magn H033 ~655.35A 100 1st No load current Io of motor Auto B023 126 10~30.00 100 Constant value of Overload restriction C111 169 ~200.0% Level2 of overload restriction warning A053 215 ~5.0s Delay time of DC braking start B045 252 00,01 Code Selection of LAD stop by torque Appendix P013 329 00~03 Code Selection of method of Pulse lines input Code Size