Hitachi SJ-PB(T) instruction manual B045 252 00,01 Code Selection of LAD stop by torque

Page 32

APPENDIX PARAMETER CROSS-REFERENCE LIST

Code

No.

Size

Range

Magn.

Contents

L300P

Read/

Write

 

 

 

 

 

 

 

b045

252

1

00,01

code

Selection of LAD stop by torque

No

R/WOS

 

 

 

 

 

 

 

 

b035

253

1

0002

code

Selection of running direction limitation

 

R/WOS

 

 

 

 

 

 

 

 

b046

254

1

00,01

code

Selection of preventive of reverse running

No

R/WOS

 

 

 

 

 

 

 

 

b036

255

1

0006

*1

Selection of method of educing voltage start

 

R/WOS

 

 

 

 

 

 

 

 

b050

257

1

00,01

code

Selection of Non stop operation

No

R/WOS

at instantaneous power failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b080

258

1

0255

*1

Adjustment of AM(analog monitor)

 

R/W

 

 

 

 

 

 

 

 

b081

259

1

0255

*1

Adjustment of FM(digital monitor)

 

R/W

 

 

 

 

 

 

 

 

b083

260

1

0.515.0kHz

*10

Carrier frequency(PWM frequency

0.512.0

R/WOS

 

 

 

 

 

 

 

 

b084

261

1

0002

code

Selection of Initialization

 

R/WOS

 

 

 

 

 

 

 

 

b085

262

1

0002

code

Selection of initialized data

 

R/WOS

 

 

 

 

 

 

 

 

b087

263

1

00,01

code

Selection of STOP key function

 

R/WOS

 

 

 

 

 

 

 

 

b088

264

1

00,01

code

Selection free run function

 

R/WOS

 

 

 

 

 

 

 

 

b091

265

1

00,01

code

Selection of action at stop

 

R/WOS

 

 

 

 

 

 

 

 

b092

267

1

00,01

code

Selection of action of cooling fan

 

R/WOS

 

 

 

 

 

 

 

 

b095

268

1

0002

code

Selection of BRD function

 

R/WOS

 

 

 

 

 

 

 

 

b098

269

1

0002

code

Selection of Thermister function

 

R/WOS

 

 

 

 

 

 

 

 

b120

270

1

00,01

code

Selection of external braking function

No

R/WOS

 

 

 

 

 

 

 

 

C001

272

1

0148,255

code

Selection of function in Intelligent input 1

0139

R/WOS

 

 

 

 

 

 

 

 

C002

273

1

0148,255

code

Selection of function in Intelligent input 2

0139

R/WOS

 

 

 

 

 

 

 

 

C003

274

1

0148,255

code

Selection of function in Intelligent input 3

0139

R/WOS

 

 

 

 

 

 

 

 

C004

275

1

0148,255

code

Selection of function in Intelligent input 4

0139

R/WOS

 

 

 

 

 

 

 

 

C005

276

1

0148,255

code

Selection of function in Intelligent input 5

0139

R/WOS

 

 

 

 

 

 

 

 

C006

277

1

0148,255

code

Selection of function in Intelligent input 6

No

R/WOS

 

 

 

 

 

 

 

 

C007

278

1

0148,255

code

Selection of function in Intelligent input 7

No

R/WOS

 

 

 

 

 

 

 

 

C008

279

1

0148,255

code

Selection of function in Intelligent input 8

No

R/WOS

 

 

 

 

 

 

 

 

C011

280

1

00,01

code

Selection of a(NO) or b(NC) contact

 

R/WOS

in Intelligent input 1

 

 

 

 

 

 

 

 

C012

281

1

00,01

code

Selection of a(NO) or b(NC) contact

 

R/WOS

in Intelligent input 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C013

282

1

00,01

code

Selection of a(NO) or b(NC) contact

 

R/WOS

in Intelligent input 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C014

283

1

00,01

code

Selection of a(NO) or b(NC) contact

 

R/WOS

in Intelligent input 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C015

284

1

00,01

code

Selection of a(NO) or b(NC) contact

 

R/WOS

in Intelligent input 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C016

285

1

00,01

code

Selection of a(NO) or b(NC) contact

No

R/WOS

in Intelligent input 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C017

286

1

00,01

code

Selection of a(NO) or b(NC) contact

No

R/WOS

in Intelligent input 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C018

287

1

00,01

code

Selection of a(NO) or b(NC) contact

No

R/WOS

in Intelligent input 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C019

288

1

00,01

code

Selection of a(NO) or b(NC) contact in

 

R/WOS

FW input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C101

289

1

00,01

code

Selection of UP/DOWN function

 

R/WOS

 

 

 

 

 

 

 

 

C102

290

1

0002

code

Selection of RESET function

 

R/WOS

 

 

 

 

 

 

 

 

C103

291

1

00,01

code

Selection of frequency matching function

 

R/WOS

at RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

Image 32
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of connecting error Otherwise, there is a danger of electric shock and/or fireOtherwise, there is a danger of electric shock Otherwise, there is a danger of fireInspection Upon Unpacking Outline of product Appearance and Names of PartsTechnical features of Profibus-DP Profibus-DP Supported VersionProduction specification Application temperature 0 to 50 degreeInstallation of option board Mounting method of option boardProfibus connectors Physical interfacePin Layout of SJ-PB Name Function Pin Layout of SJ-PBTWiring note PROFIBUS-DPProfibus Configuration Node AddressBaudrate PPO-type selectionP001/P002 Action at error detection Remarks Setting of controlling frequency and start/stop commandsAction at communication error PPO- description OperatingPKW-part PCA wordRequest Function Ackn + Response ID FunctionPZD-part Control- / status word STW/ZSWStatus word Profidrive state diagram Frequency set-point/ Actual frequencyPZD word Please NoteWriting a two byte array parameter Parameter ExamplesWriting a four byte parameter Writing a two byte array parameter #2 Profidrive specific parameters Profidrive parametersFault code SJ300/L300P Fault description Parameter Malfunction codesTrip display Protection function listCountermeasure for a trip state LED display and CountermeasureCode Size Range Magn Contents L300P Read Parameter cross-reference listCode Size Range Magn H033 ~655.35A 100 1st No load current Io of motor Auto B023 126 10~30.00 100 Constant value of Overload restriction C111 169 ~200.0% Level2 of overload restriction warning A053 215 ~5.0s Delay time of DC braking start B045 252 00,01 Code Selection of LAD stop by torque Appendix P013 329 00~03 Code Selection of method of Pulse lines input Code Size