CHAPTER 1 INTRODUCTION

1.3 Outline of product

SJ-PB(T) is Profibus-DP communication board for SJ300/L300P series inverter.

SJ300/L300P series inverter can get to connect another devices via Profibus-DP when install SJ-PB(T). SJ-PB(T) is possible to use for all models of SJ300/L300P series.

The SJ-PB(T) option board communicates according to the Profibus Protocol Standard DIN 19245 part 1 & 3. This means that it can communicate with all masters that comply with this standard, but it does not necessarily mean that all services available in the Profibus standard are supported. The “Profibus Profile for Variable Speed Drives” (order no. 3.072), also known as Profidrive, is a subset of Profibus which only supports the services relevant to speed control applications.

In a control system the option board will act as a slave that can be read and written to, from a Profibus-DP master. It will not initiate communication to other nodes, it will only respond to incoming telegrams.

(Note) RS485 communication function is disabled by installing SJ-PB(T) to the inverter.

Difference between SJ-PB and SJ-PBT is only connector for networking. Others are no difference.

1.4 Appearance and Names of Parts

Figure 1-1 indicates the appearance of SJ-PB(T).

Connector for connection to SJ300/L300P(Rear of unit)

Left rotary switch for setting Node Address (one to nine) (note)

Right rotary switch for setting Node Address (a times ten factor) (note)

note: please see chapter 4.1.1 Node Address

5

5

0

0

Fieldbus On/Off (D14)

Profibus contact (open type)

 

Fieldbus diagnosis (D13)

 

Serial channel status (D12)

 

Figure 1-1 Appearance of SJ-PB(T)

2

Image 6
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of electric shock Otherwise, there is a danger of connecting errorOtherwise, there is a danger of electric shock and/or fire Otherwise, there is a danger of fireInspection Upon Unpacking Outline of product Appearance and Names of PartsTechnical features of Profibus-DP Profibus-DP Supported VersionProduction specification Application temperature 0 to 50 degreeInstallation of option board Mounting method of option boardPin Layout of SJ-PB Name Function Profibus connectorsPhysical interface Pin Layout of SJ-PBTWiring note PROFIBUS-DPBaudrate Profibus ConfigurationNode Address PPO-type selectionSetting of controlling frequency and start/stop commands Action at communication errorP001/P002 Action at error detection Remarks PPO- description OperatingPKW-part PCA wordRequest Function Ackn + Response ID FunctionPZD-part Control- / status word STW/ZSWStatus word Profidrive state diagram Frequency set-point/ Actual frequencyPZD word Please NoteParameter Examples Writing a four byte parameterWriting a two byte array parameter Writing a two byte array parameter #2 Profidrive specific parameters Profidrive parametersFault code SJ300/L300P Fault description Parameter Malfunction codesCountermeasure for a trip state Trip displayProtection function list LED display and CountermeasureCode Size Range Magn Contents L300P Read Parameter cross-reference listCode Size Range Magn H033 ~655.35A 100 1st No load current Io of motor Auto B023 126 10~30.00 100 Constant value of Overload restriction C111 169 ~200.0% Level2 of overload restriction warning A053 215 ~5.0s Delay time of DC braking start B045 252 00,01 Code Selection of LAD stop by torque Appendix P013 329 00~03 Code Selection of method of Pulse lines input Code Size