Hitachi SJ-PB(T) instruction manual Code Size Range Magn

Page 27

 

 

 

 

 

APPENDIX

PARAMETER CROSS-REFERENCE LIST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

No.

Size

Range

Magn.

 

Contents

L300P

Read/

 

 

 

Write

 

 

 

 

 

 

 

 

 

 

 

 

A011

36

4

0400.00Hz

*100

 

O Start frequency set

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A012

37

4

0400.00Hz

*100

 

O End frequency set

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A111

38

4

-400.00

*100

 

O2 Start frequency set

 

R/WOS

 

 

400.00Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A112

39

4

-400.00

*100

 

O2 End frequency set

 

R/WOS

 

 

400.00Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A101

40

4

0400.00Hz

*100

 

OI Start frequency set

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A102

41

4

0400.00Hz

*100

 

OI End frequency set

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A063

43

4

0400.00Hz

*100

 

Jumping frequency 1

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A065

44

4

0400.00Hz

*100

 

Jumping frequency 2

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A067

45

4

0400.00Hz

*100

 

Jumping frequency 3

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

A069

46

4

0400.00Hz

*100

Frequency of stopping acceleration

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

A095

47

4

0400.00Hz

*100

1st Frequency of 2-stage acceleration

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

A295

48

4

0400.00Hz

*100

2nd Frequency of 2-stage acceleration

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

A096

49

4

0400.00Hz

*100

1st Frequency of 2-stage deceleration

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

A296

50

4

0400.00Hz

*100

2nd Frequency of 2-stage deceleration

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

b007

51

4

0400.00Hz

*100

Frequency of frequency matching

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

b053

52

4

0.013600.00s

*100

Deceleration time of Non-stop operation

No

R/WOS

 

 

at Instantaneous power failure

 

 

 

 

 

 

 

 

 

 

 

C042

53

4

0400.00Hz

*100

Arrival frequency at acceleration1

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

C043

54

4

0400.00Hz

*100

Arrival frequency at deceleration1

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

C045

55

4

0400.00Hz

*100

Arrival frequency at acceleration2

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

C046

56

4

0400.00Hz

*100

Arrival frequency at deceleration2

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A003

58

2

30400Hz

*1

 

1st Base frequency

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A203

59

2

30400Hz

*1

 

2nd Base frequency

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A303

60

2

30400Hz

*1

 

3rd Base frequency

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A038

61

2

09.99Hz

*100

 

Jogging frequency

 

R/W

 

 

 

 

 

 

 

 

 

 

 

 

 

A004

62

2

30400Hz

*1

 

1st Maximum frequency

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A204

63

2

30400Hz

*1

 

2nd Maximum frequency

 

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

A304

64

2

30400Hz

*1

 

3rd Maximum frequency

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H020

66

4

065.530Ω

*1000

1st Primary resistor R1 of motor

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H220

67

4

065.530Ω

*1000

2nd Primary resistor R1 of motor

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H021

68

4

065.530Ω

*1000

1st Secondary resistor R2 of motor

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H221

69

4

065.530Ω

*1000

2nd Secondary resistor R2 of motor

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

H022

70

4

0655.35mH

*100

 

1st Inductance L of motor

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

H222

71

4

0655.35mH

*100

 

2nd Inductance L of motor

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H023

72

4

0655.35A

*100

1st No load current Io of motor

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H223

73

4

0655.35A

*100

2nd No load current Io of motor

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

 

H024

74

4

0.001

*100

 

1st Inertia J of motor

No

R/WOS

 

 

9999.000kgm2

 

 

 

 

 

 

 

 

 

 

 

 

 

H224

75

4

0.001

*100

 

2nd Inertia J of motor

No

R/WOS

 

 

9999.000kgm2

 

 

 

 

 

 

 

 

 

 

 

 

 

H030

76

4

065.5350Ω

*1000

1st Primary resistor R1 of motor (Auto)

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H230

77

4

065.530Ω

*1000

2nd Primary resistor R1 of motor (Auto)

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H031

78

4

065.530Ω

*1000

1st Secondary resistor R2 of motor (Auto)

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H231

79

4

065.530Ω

*1000

2nd Secondary resistor R2 of motor (Auto)

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H032

80

4

0655.35mH

*100

1st Inductance L of motor (Auto)

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

H232

81

4

0655.35mH

*100

2nd Inductance L of motor (Auto)

No

R/WOS

 

 

 

 

 

 

 

 

 

 

 

 

23

Image 27
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of fire Otherwise, there is a danger of connecting errorOtherwise, there is a danger of electric shock and/or fire Otherwise, there is a danger of electric shockInspection Upon Unpacking Appearance and Names of Parts Outline of productProfibus-DP Supported Version Technical features of Profibus-DPApplication temperature 0 to 50 degree Production specificationMounting method of option board Installation of option boardPin Layout of SJ-PBT Profibus connectorsPhysical interface Pin Layout of SJ-PB Name FunctionPROFIBUS-DP Wiring notePPO-type selection Profibus ConfigurationNode Address BaudrateSetting of controlling frequency and start/stop commands Action at communication errorP001/P002 Action at error detection Remarks Operating PPO- descriptionPCA word PKW-partResponse ID Function Request Function Ackn +Control- / status word STW/ZSW PZD-partStatus word Frequency set-point/ Actual frequency Profidrive state diagramPlease Note PZD wordParameter Examples Writing a four byte parameterWriting a two byte array parameter Writing a two byte array parameter #2 Profidrive parameters Profidrive specific parametersMalfunction codes Fault code SJ300/L300P Fault description ParameterLED display and Countermeasure Trip displayProtection function list Countermeasure for a trip stateParameter cross-reference list Code Size Range Magn Contents L300P ReadCode Size Range Magn H033 ~655.35A 100 1st No load current Io of motor Auto B023 126 10~30.00 100 Constant value of Overload restriction C111 169 ~200.0% Level2 of overload restriction warning A053 215 ~5.0s Delay time of DC braking start B045 252 00,01 Code Selection of LAD stop by torque Appendix P013 329 00~03 Code Selection of method of Pulse lines input Code Size