Hitachi SJ2-CO instruction manual Communication Objects Lists

Page 31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER7

COMMUNICATION OBJECTS LISTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDEX

Parameter

Function Name

 

 

 

Size

Unit

Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x24A1

A101

OI start

 

 

 

 

2

0.1Hz

 

 

 

0x24A2

A102

OI end

 

 

 

 

2

0.1Hz

 

 

 

0x24A3

A103

OI start rate

 

 

 

 

1

1.%

 

 

 

0x24A4

A104

OI end rate

 

 

 

 

1

1.%

 

 

 

0x24A5

A105

OI start selection

 

 

 

1

-

 

 

 

0x24E1

A141

Cal.frequency1

 

 

 

1

-

 

 

 

0x24E2

A142

Cal.frequency2

 

 

 

1

-

 

 

 

0x24E3

A143

Cal. select

 

 

 

 

1

-

 

 

 

0x24E5

A145

Set point frequency

 

 

 

2

0.1Hz

 

 

 

0x24E6

A146

Plus/Minus select

 

 

 

1

-

 

 

 

0x24F1

A151

Pot start

 

 

 

 

2

0.1Hz

 

 

 

0x24F2

A152

Pot end

 

 

 

 

2

0.1Hz

 

 

 

0x24F3

A153

Pot start rate

 

 

 

 

1

1.%

 

 

 

0x24F4

A154

Pot end rate

 

 

 

 

1

1.%

 

 

 

0x24F5

A155

Pot start selection

 

 

 

1

-

 

 

 

0x2601

b001

Automatic Restart Selection

 

 

1

-

 

 

 

0x2602

b002

Allowable under-voltage power failure time

 

1

0.1

 

 

 

0x2603

b003

Retry wait time

 

 

 

2

0.1sec

 

 

 

0x2604

b004

Instantaneous

power

failure/under-voltage

trip

 

 

 

 

 

during stop

 

 

 

 

1

-

 

 

 

 

 

 

 

 

 

 

 

 

0x2605

b005

Instantaneous

power

failure/under-voltage

retry

 

 

 

 

 

time selection

 

 

 

 

1

-

 

 

 

 

 

 

 

 

 

 

 

 

0x2612

b012

Electronic thermal level

 

 

2

0.01%

 

 

 

0x2712

b212

Electronic thermal level(2nd motor)

 

 

2

0.01%

 

 

 

0x2613

b013

1st electronic thermal characteristic selection

 

1

-

 

 

 

0x2713

b213

2nd electronic thermal characteristic selection

1

-

 

 

 

0x2621

b021

Overload restriction operation mode

 

1

-

 

 

 

0x2721

b221

Overload restriction operation mode,2nd motor

1

-

 

 

 

0x2622

b022

Overload restriction setting

 

 

2

0.01%

 

 

 

0x2722

b222

Overload restriction setting,2nd motor

 

2

0.01%

 

 

 

0x2623

b023

Deceleration rate at Overload restriction

 

2

0.1sec

 

 

 

0x2723

b223

Deceleration

rate at

Overload

restriction,2nd

 

 

 

 

 

motor

 

 

 

 

2

0.1sec

 

 

 

 

 

 

 

 

 

 

 

 

0x2628

b028

Overload restriction source selection

 

1

-

 

 

 

0x2728

b228

Overload restriction source selection, 2nd motor

1

-

 

 

 

0x2631

b031

Software lock mode selection

 

 

1

-

 

 

 

0x2680

b080

AM adjustment

 

 

 

1

1.%

 

 

 

0x2682

b082

Start frequency adjustment

 

 

2

0.1Hz

 

 

 

0x2683

b083

Carrier Frequency setting

 

 

1

0.1kHz

 

 

 

0x2684

b084

Initialization mode

 

 

 

1

-

 

 

 

0x2685

b085

Country code for initialization

 

 

1

-

 

 

 

0x2686

b086

Frequency scaling conversion factor

 

2

0.1

 

 

 

0x2687

b087

STOP key enable

 

 

 

1

-

 

 

 

0x2688

b088

Restart mode after FRS

 

 

1

-

 

 

 

0x2689

b089

Monitoring selection

 

 

 

1

-

 

 

 

0x2690

b090

Dynamic braking usage

 

 

2

0.1%

 

 

27

Image 31
Contents Hitachi Inverter Revision History Table Safty Precautions Otherwise, there is a danger of electric shock and/or injury Request upon inquiring Warranty of the productAppearance of SJ2-CO Appearance and Names of PartsCANopen Support Version Specifications LabelLED display Mounting method of option Installation of SJ2-CO SJ200-2 + SJ2-COSJ2-MF SJ2-CCV Communication cable for CANopen Connection for CANopen connectorPLC Wiring noteSetting method of CANopen Baud rate Setting methods of Baud rate and Node IDSetting method of CANopen Node Power Supply LED check Parameter setting of the InverterCanopen Communication Function PDOProcess Data Object Object Dictionary for Standardized Device Profile Area Device ControlAbortconnectionoptioncode Index 6007h Control word Index 6040h Status word Index 6041h State Machine PowerRFG Using RFGRamp Function GeneratorVlvelocityminmaxamount Index 6046h Vltargetvelocity Index 6042hVlvelocitydemand Index 6043h Vlvelocityeffort Index 6044hVlvelocitydeceleration Index 6049h Vlvelocityacceleration Index 6048hKeypad displayOPTIONAL OPERATOROPE-SRMINI Modesofoperation Index 6060h/6061hProtection function list Trip displayCountermeasure for a trip state LED LED display and CountermeasureDevice Profile Area Communication ObjectsIndex Profile Manufacyure Objects d,F groupProfile Manufacture Objects A,b,C,H,P group Parameter Communication Objects Lists Communication Objects Lists Saving Parameters to Eeprom Dimension Contact Information