Kodak
i1800 Series
manual
UDDS Calibration
Troubleshooting
Specification
Install
error condition
Maintenance
Problem solving
Accessing scanner
Remove one core assembly
Adjusting the input elevator
Settings screen
Page 42
Page 41
Page 43
Image 42
Page 41
Page 43
Contents
i1800 Series Scanners
User’s Guide
A-61555
Contents
A-61555March
A-61555March
Appendix A
Appendix B
1 Introduction
Scanner features
System requirements
Supporting documentation
Contacting Service and Support
Phone numbers •United States and Canada
MSDS
Safety information
User precautions
Gas springs warning
Environmental information
European Union
EMC statements
United States
connection
Power system
Acoustic emission
Peoples Republic of
2 Getting Started
Scanner components Front view
15 18
11Exit deflector — aids in document stacking
A-61555March
Internal components
Rear view
3 Using the Scanner
Turning the scanner on
A-61555March
Document preparation
Turning the scanner off
Starting and stopping scanning
Materials
A-61555March
position
Adjusting the input elevator
Selecting your feeding
Locking the side guides
Adjusting the height of the input elevator
Adjusting the input tray for document length
Adjusting the side guides
Adjusting the output tray
Installing the document
Output tray options
Positioning the output tray
1 2 3
Adjusting the end stop
Adjusting the angle of the output tray
3-10
The exit deflector
Adjusting the output tray
for documents from
34 in
Adjusting the short document tray
3. Adjust the sides guides as necessary
1.Remove the end stop on the output tray
Adjusting the height of the scanner
Feeding documents using multi-feeddetection
Automatic feeding
Continuous feeding Manual feeding
Feeding documents that require special handling
Using the operator control panel touchscreen
Settings screen
3.Touch Close to return to the Settings screen
3-20
Selecting the tone
Selecting a language
Scanner only
Enabling/disabling image
addressing for
cycle the scanner
4.Restart the scanner
3-24
Image Calibration
UDDS Calibration
Idle screen
Image Address information
Operator Log
Accessing scanner
information
Count only mode
Performing a Print test
Performing a self test
Scanning
Using function keys when scanning
Automatically pausing and resuming the scanner
Manually pausing and resuming the scanner
Power Saver mode Viewing messages
Resuming from Power Saver mode
4 The Enhanced Printer and Patch Readers
Enhanced Printer overview
Printer specifications
Changing print positions
Changing the front horizontal print position
Changing the rear
horizontal print position
3.Lift the printer carrier out of position
1.Open the top access cover
Replacing the ink cartridge
9.Run a print test
Replacing the front blotter strips
10.Close the pod
7.Press the blotter strip firmly into the channel
9.Replace the ink blotter strip cover
4-10
Replacing the rear blotter strips
Patch types
Patch function overview
The Patch Readers
they are not to spec
Patch code placement
Toggle Patch
5 Maintenance
Cleaning frequency chart
Cleaning tools and materials
•Kodak Digital Science Roller Cleaning Pads
3E9575
Supplies, consumables and accessories
Ordering parts
9E3357
Cleaning procedures
Cleaning the OCP touchscreen
Vacuuming the output tray and input elevator
Cleaning the rollers
Cleaning the separation roller tires
Cleaning the feed module tires
9. Lift up the printer access cover
14. Close the printer access cover
Vacuuming the transport area
Vacuuming under the background strips
Cleaning the imaging
guides — basic cleaning
Cleaning the imaging guides — thorough cleaning
Upper imaging guide
Lower imaging guide
cleaning sheet
Running a transport
Final cleaning steps
Replacement procedures
•Close the pod and the printer access cover
7.Remove one core assembly
15.Close the pod
1.Open the pod
Replacing the imaging
Replacing the pre
separation pad
guides
6 Troubleshooting
Accessing the Operator Log
Accessing the Operator Log from the touchscreen
2.From the Driver Types box, select TWAIN
4. Select the Scanner icon
5. From the main screen, click Settings
The Settings screen will be displayed
6. Select Device
The Device screen will be displayed
8.Select the Logs tab
Use the button to create a compressed log package
Message listing
A-61555March
Input elevator too full, feed module
A-61555March
UDDS calibration failed
error condition
Numerical message
listing
6-10
Contacting Service
phone numbers and detailed information
Problem solving
6-12
Calibration has failed
Background Accessory Kodak Manual Feeder
Appendix A Accessories
Ultralightweight Paper Feed Module
Resolution Printer Accessory
Specifications
Appendix B
Eastman Kodak Company 343 State Street
Rochester, NY 14650 U.S.A
Kodak, 2007. All rights reserved. TM Kodak
Related pages
How do I assemble the
Bifinett KH 700
for first use?
Top
Page
Image
Contents