Kodak i1800 Series manual Message listing, A-61555March

Page 90
Message listing

Message listing

Following is an alphabetic list of messages and corrective actions you can take if one of the following messages is encountered.

Messages

ID#

Operator Message

Background accessory changed

381

The Background Accessory was changed while the scanner was

while powered up

 

powered on.

 

 

• Turn the power off to the scanner, wait a few seconds and

 

 

power the scanner back on.

 

 

• If you get this message and you did not change the

 

 

Background Accessory, clean the scanner.

 

 

 

Cable unplugged

319

Some device on the FireWire bus was unplugged/plugged in.

 

 

• Check that all FireWire connectors are securely fastened.

 

 

 

Calibration failed

106, 331

• Clean the imaging guides. See Chapter 5, Maintenance for

 

 

procedures.

 

 

• Try to calibrate the scanner again. Be sure you are using the

 

 

correct calibration target. See Chapter 3, “Calibrating the

 

 

scanner”.

 

 

• The calibration target is too small. A 12- x 12-inch calibration

 

 

target is required for image calibration.

 

 

• Calibration target is too narrow.

 

 

• If the problem persists, call Service.

 

 

 

Calibration succeeded

105, 342

Informational message. The scanner has been successfully

 

 

calibrated.

Call Service

Many ID

A condition was detected that may require repair.

 

numbers

• Turn the power off to the scanner, wait a few seconds and

 

 

power the scanner back on.

 

 

• If the problem persists, call Service and provide the ID number

 

 

of the error.

Cannot calibrate with white

184

Both a front and rear print head is installed in the scanner. Only

background

 

one print head can be installed at one time.

 

 

• Remove one of the print heads.

 

 

 

Cannot run with both printers

90

The White Background Accessory is installed in the scanner

installed

 

while the scanner is trying the calibrate.

 

 

• Remove the White Background Accessory before calibrating

 

 

the scanner.

Check document preparation

123, 135,

• The gap between your documents is too small.

 

81

• Make sure the leading edges of the documents are aligned.

 

 

See Chapter 3, “Document preparation” for more information.

 

 

• Check the condition of your feed module and separation roller

 

 

tires and your pre-separation pad. Clean and replace if

 

 

necessary.

 

 

 

Check imaging guides and lamps

149, 178,

• Verify that the imaging guides are installed correctly. See

 

139

Chapter 5, Maintenance.

 

 

• Clean both sides of the imaging guides and lower glass plate

 

 

between the lamps.

 

 

• Check that the white patch on the imaging guides is clean and

 

 

in good condition.

 

 

• If the problem persists, call Service.

 

 

 

Clean lower imaging guide

294

The lower imaging guide is dirty or there may be a small piece of

 

 

paper in the imaging guide area.

 

 

• Clean the imaging guides. See Chapter 5, Maintenance for

 

 

procedures.

 

 

 

A-61555 March 2007

6-5

Image 90
Contents i1800 Series Scanners User’s GuideA-61555 Contents A-61555MarchA-61555March Appendix A Appendix B1 Introduction Scanner features System requirements Supporting documentationContacting Service and Support Phone numbers •United States and CanadaMSDS Safety informationUser precautions Gas springs warningEnvironmental information European UnionEMC statements United Statesconnection Power systemAcoustic emission Peoples Republic of2 Getting Started Scanner components Front view15 18 11Exit deflector — aids in document stackingA-61555March Internal components Rear view 3 Using the Scanner Turning the scanner onA-61555March Document preparation Turning the scanner offStarting and stopping scanning MaterialsA-61555March position Adjusting the input elevatorSelecting your feeding Locking the side guidesAdjusting the height of the input elevator Adjusting the input tray for document lengthAdjusting the side guides Adjusting the output trayInstalling the document Output tray optionsPositioning the output tray 1 2 3Adjusting the end stop Adjusting the angle of the output tray3-10 The exit deflector Adjusting the output tray for documents from34 in Adjusting the short document tray 3. Adjust the sides guides as necessary1.Remove the end stop on the output tray Adjusting the height of the scanner Feeding documents using multi-feeddetection Automatic feedingContinuous feeding Manual feeding Feeding documents that require special handling Using the operator control panel touchscreen Settings screen 3.Touch Close to return to the Settings screen 3-20Selecting the tone Selecting a language Scanner only Enabling/disabling imageaddressing for cycle the scanner4.Restart the scanner 3-24Image Calibration UDDS Calibration Idle screen Image Address informationOperator Log Accessing scanner informationCount only mode Performing a Print test Performing a self test Scanning Using function keys when scanning Automatically pausing and resuming the scanner Manually pausing and resuming the scannerPower Saver mode Viewing messages Resuming from Power Saver mode4 The Enhanced Printer and Patch Readers Enhanced Printer overviewPrinter specifications Changing print positions Changing the front horizontal print positionChanging the rear horizontal print position3.Lift the printer carrier out of position 1.Open the top access cover Replacing the ink cartridge 9.Run a print test Replacing the front blotter strips 10.Close the pod 7.Press the blotter strip firmly into the channel9.Replace the ink blotter strip cover 4-10Replacing the rear blotter strips Patch types Patch function overviewThe Patch Readers they are not to specPatch code placement Toggle Patch5 Maintenance Cleaning frequency chart Cleaning tools and materials•Kodak Digital Science Roller Cleaning Pads 3E9575 Supplies, consumables and accessoriesOrdering parts 9E3357Cleaning procedures Cleaning the OCP touchscreenVacuuming the output tray and input elevator Cleaning the rollers Cleaning the separation roller tires Cleaning the feed module tires 9. Lift up the printer access cover14. Close the printer access cover Vacuuming the transport area Vacuuming under the background stripsCleaning the imaging guides — basic cleaningCleaning the imaging guides — thorough cleaning Upper imaging guideLower imaging guide cleaning sheet Running a transportFinal cleaning steps Replacement procedures •Close the pod and the printer access cover 7.Remove one core assembly 15.Close the pod 1.Open the pod Replacing the imaging Replacing the preseparation pad guides6 Troubleshooting Accessing the Operator LogAccessing the Operator Log from the touchscreen 2.From the Driver Types box, select TWAIN 4. Select the Scanner icon5. From the main screen, click Settings The Settings screen will be displayed6. Select Device The Device screen will be displayed 8.Select the Logs tabUse the button to create a compressed log package Message listing A-61555March Input elevator too full, feed module A-61555March UDDS calibration failed error condition Numerical messagelisting 6-10Contacting Service phone numbers and detailed informationProblem solving 6-12Calibration has failed Background Accessory Kodak Manual Feeder Appendix A AccessoriesUltralightweight Paper Feed Module Resolution Printer AccessorySpecifications Appendix BEastman Kodak Company 343 State Street Rochester, NY 14650 U.S.AKodak, 2007. All rights reserved. TM Kodak