Agilent Technologies G1978B setup guide U T I O N Wa R N I N G

Page 2

Notices

© Agilent Technologies, Inc. 2008

No part of this manual may be reproduced in any form or by any means (including elec- tronic storage and retrieval or translation into a foreign language) without prior agree- ment and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws.

Manual Part Number

G1978-90070

Edition

First Edition, December 2008

Printed in USA

Agilent Technologies, Inc.

5301 Stevens Creek Blvd.

Santa Clara, CA 95051 USA

Windows® and MS Windows® are U.S. registered trademarks of Microsoft Corpora- tion.

Windows NT® is a U.S. registered trade- mark of Microsoft Corporation.

Warranty

The material contained in this docu- ment is provided “as is,” and is sub- ject to being changed, without notice, in future editions. Further, to the max- imum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a par- ticular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connec- tion with the furnishing, use, or per- formance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the sep- arate agreement shall control.

Technology Licenses

The hardware and/or software described in this document are furnished under a license and may be used or copied only in accor- dance with the terms of such license.

Restricted Rights Legend

U.S. Government Restricted Rights. Soft- ware and technical data rights granted to the federal government include only those rights customarily provided to end user cus- tomers. Agilent provides this customary commercial license in Software and techni- cal data pursuant to FAR 12.211 (Technical Data) and 12.212 (Computer Software) and, for the Department of Defense, DFARS 252.227-7015 (Technical Data - Commercial Items) and DFARS 227.7202-3 (Rights in Commercial Computer Software or Com- puter Software Documentation).

Safety Notices

C A U T I O N

A CAUTION notice denotes a haz- ard. It calls attention to an operat- ing procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.

WA R N I N G

A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly per- formed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated condi- tions are fully understood and met.

2

Multimode Source for 6100 Series Single Quad LC/MS Set-Up Guide

Image 2
Contents Set-Up Guide U T I O N WA R N I N G This Guide Page Content Contents Installation Installation Prepare to installInstall the HV control PCA and cables From left to right G1946-80058, G1960-60802 and G1960-60856Connecting the valve PCA to the multimode HV power supply Connecting the Vcap and Vchamber cables to the power supply Connecting the HV PCA to the chassis Changing Sources To remove the multimode sourceTo convert from multimode to ESI, Apci or Appi Installation on To convert from ESI, Apci or Appi to the multimode sourceStandard spray shield and capillary cap for ESI or Apci T E Multimode Spray Chamber No nebulizer on top of the multimode source LC/MS sample tubing connected to LC/MS inlet filter Verification Preparation 6110 and 6120 Quad Performance Verification Summary Table 6140 Quad Performance Verification Summary, SIM Mode 20 1 pk-pk 10 1 pk-pk Verification 6140 Quad Performance Verification Summary, Scan Mode 6130SCNESMM.M 6130SCNCIMM.M Verification Create and run a Multiple FIA Method Sequence Verification To do an autotune Autotune reportExample of multimode verification report Example of multimode verification report Methods To setup a method to use the multimode source Be impaired and the system may catch fireMethods Polarity options for Signal 1 and Signal To create a method for alternating ESI and Apci operation Method Spray Chamber set to MM-ES+APCIIonization mode for Signal 1 and Signal Index Index Page G1978-90070

G1978B specifications

Agilent Technologies G1978B is a high-performance mass spectrometer that is widely recognized for its innovations in analytical chemistry. This instrument stands out due to its combination of advanced technologies that enhance sensitivity, accuracy, and precision for complex analyses.

One of the key features of the G1978B is its compatibility with various ionization techniques, including Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI). This versatility allows users to analyze a diverse range of sample types, from small molecules to large biomolecules. Each ionization technique has its unique advantages, making the G1978B an excellent choice for laboratories focusing on pharmaceuticals, environmental analysis, and proteomics.

The G1978B is equipped with a sophisticated quadrupole mass filter, ensuring high-resolution mass measurements. This technology provides excellent mass accuracy and reproducibility, enabling users to distinguish between closely related compounds with minimal interference. The advanced data acquisition systems incorporated in the G1978B allow for rapid scanning capabilities, making it particularly effective for high-throughput screening applications.

In addition, the instrument features an intuitive user interface that simplifies method development and operational tasks. This includes streamlined software solutions that facilitate data analysis and interpretation, ensuring that even complex datasets can be managed efficiently. Furthermore, built-in diagnostic tools help in monitoring instrument performance, significantly reducing downtime and enhancing productivity.

The G1978B also incorporates advanced technologies for enhanced sensitivity. Its innovative source design minimizes background noise while maximizing signal intensity, making it particularly valuable for the detection of trace-level contaminants or low-abundance metabolites. Coupled with its exceptional dynamic range, the G1978B can quantify analytes over several orders of magnitude, which is crucial for applications in toxicology and clinical research.

With a robust design and ease of integration into existing laboratory workflows, the Agilent G1978B provides an ideal solution for researchers seeking a reliable mass spectrometry platform. Its combination of advanced ionization techniques, high-resolution capabilities, and user-friendly software makes it a versatile tool in modern analytical laboratories, paving the way for breakthroughs in research and development across a multitude of scientific disciplines.