Mean printing life | Starter cartridge: 4000 sheets given a 5% coverage life | ||
| Replacement cartridge: 4000 sheets given a 5% coverage | ||
|
|
| life |
Power specifications |
|
|
|
Input line voltage/ | For US | Voltage | Frequency |
frequency | Min.: | 90V | 47Hz |
| Normal: | 100/120V 50/60Hz | |
| Max.: | 132V | 63Hz |
| For Europe and Asia/Pacific | ||
| Voltage | Frequency |
|
| Min.: | 198V | 47Hz |
| Normal: | 220/240V 50/60Hz | |
| Max.: | 264V | 63Hz |
Power consumption | Maximum power consumption at | ||
| printing is as follows |
| |
| 100/120V | Less than 400W (less than 3A) | |
| 220/240V | Less than 400W (less than 2A) | |
Environmental |
|
|
|
specifications | Energy Star Compliant |
| |
Temperature, humidity | Print engine with toner cartridge: | ||
and altitude | Operating: 5 – 35°C (41 – 95°F) at 15 – 85% RH | ||
| (no condensation) |
| |
| |||
| (no condensation) |
| |
| 0 – 2,500 meters (0 – 8,200 feet) | ||
| Print engine without toner cartridge | ||
| |||
| (no condensation) |
| |
| 0 – 15,000 meters (0 – 49,200 feet) | ||
Acoustic noise | Printing: | 48 dB (A) or less | |
| Warm up: | 38 dB (A) or less | |
| In accordance with ISO 7779 | ||
Dust emission | Less than 0.1mg/m3 |
| |
concentration: | Measured in accordance with Mass Measurements | ||
| Method |
|
|
76