When the output is tripped the OUTPUT lamp will still be ON but the displays will show ‘OP trip’ and the UNREG lamp will also light. Turn the output off; the trip message should be replaced with the normal preset V and I readings. When the cause of the trip has been removed the output can be switched on again.

Even with the output off the load is still connected to the power supply output stage. Do not apply external voltages in excess of 70V to the power supply terminals or damage may result.

The output is protected from reverse voltages by a diode; the continuous reverse current must not exceed 3 Amps, although transients can be much higher.

Over-temperature Protection

Sensors on both the secondary heatsinks will detect over-temperature due to blocked air flow, fan failure or other circuit fault. Over-temperature will shut down the output (the display will read 0 Volts and 0 Amps if the output is ON) though the output ON lamp will remain lit. The output will remain shut down even after the heatsinks have cooled down. When the cause of the over- temperature has been removed and the heatsinks have cooled to normal working temperatures the output can be reset by turning the POWER switch to standby ( ) then on ( l ) again.

Maintenance

The Manufacturers or their agents overseas will provide repair for any unit developing a fault. Where owner wish to undertake their own maintenance work, this should only be done by skilled personnel in conjunction with the service manual which may be purchased directly from the Manufacturers or their agents overseas.

Fuse

The correct fuse type is:

15 Amp 250V HBC time-lag, 1¼” x ¼”

Make sure that only fuses of the required rated current and specified type are used for replacement. The use of makeshift fuses and the short-circuiting of fuse-holders is prohibited.

To replace the fuse, first disconnect the instrument from the AC supply. Remove the 6 cover securing screws and lift off the cover. Replace the fuse with one of the correct type and refit the cover.

Note that the main function of the fuse is to make the instrument safe and limit damage in the event of failure of one of the switching devices. If a fuse fails it is therefore very likely that the replacement will also blow, because the supply has developed a fault; in such circumstances the instrument will need to be returned to the manufacturer for service.

Cleaning

If the PSU requires cleaning use a cloth that is only lightly dampened with water or a mild detergent. Polish the display window with a soft dry cloth.

WARNING! TO AVOID ELECTRIC SHOCK, OR DAMAGE TO THE PSU, NEVER ALLOW WATER TO GET INSIDE THE CASE. TO AVOID DAMAGE TO THE CASE OR DISPLAY WINDOW NEVER CLEAN WITH SOLVENTS.

10

Image 11
Contents XPF XPF Series Dual Output 60V 20A Powerflex DC Power SupplyContact Information Part Number and RevisionTable of Contents Output Specifications SpecificationMeter Specifications Safety Immunity EmissionsConnections InstallationOperation Protection Connection to the LoadRemote Sensing Series or Parallel connection with other unitsFuse MaintenanceOver-temperature Protection CleaningEquipment Required Access to Calibration AdjustmentsCalibration Set OVP Voltage CalibrationCurrent Calibration Voltage RegulationAVERTISSEMENT! CET Instrument Doit Etre Relie a LA Terre SécuritéMontage ConnexionsTension d’utilisation secteur Câble secteurOpération Connexion en série ou en parallèle avec d’autres appareils Connexion à la chargeTélédétection Nettoyage Protection contre la surchauffeFusible WARNUNG! Dieses Gerät Muss Geerdet Werden SicherheitBelüftung AnschlüsseNetzbetriebsspannung NetzkabelBetrieb Reihen- und Parallelschaltung mit anderen Geräten VerbraucheranschlussIstwert-Fernerfassung Übertemperaturschutz ÜberspannungsschutzReinigung WartungSicherung Attenzione Questo Strumento Deve Essere Collegato a Terra SicurezzaCollegamento InstallazioneFunzionamento Protezione Allacciamento del caricoRilevamento a distanza Collegamento in serie/parallelo con altre unitàPulizia ManutenzioneProtezione da temperatura eccessiva FusibileADVERTENCIA! Este Instrumento Debe Conectarse a Tierra SeguridadConexiones InstalaciónFuncionamiento Protección Conexión a la cargaDetector remoto Conexión en serie o en paralelo a otras unidadesLimpieza MantenimientoProtección contra Sobretemperatura How do you get service? Warranty InformationProduct What does this warranty not cover?Xantrex Technology Inc