Xantrex Technology XPF 60-20 manual Meter Specifications

Page 5

Transient Load Response:

<250us to within 50mV of set level for a 5% to 95% load change.

Temperature Coefficient:

Typically <100ppm/°C

Status Indication:

Output on lamp.

 

Constant voltage mode lamp.

 

Constant current mode lamp.

 

Unregulated (power limit) lamp

 

Trip message on display.

METER SPECIFICATIONS

Meter Types:

Dual 4 digit meters with 12.5mm (0.5") LEDs. Reading rate 4 Hz.

Meter Resolutions:

10mV, 10mA

Meter Accuracies:

Voltage 0.1% of reading ± 2 digits,

 

Current 0.3% of reading ± 2 digits

GENERAL

AC Input:

110V – 240V AC ± 10%, 50/60Hz.

 

Installation Category II.

Power Consumption:

1250VA max.

Operating Range:

+5ºC to +40ºC, 20% to 80% RH.

Storage Range:

40ºC to + 70ºC.

Environmental:

Indoor use at altitudes up to 2000m, Pollution Degree 2.

Safety:

Complies with EN61010-1.

EMC:

Complies with EN61326.

Size:

210 x 130 x 375mm (WxHxD) half rack width x 3U height (optional

 

rack mounting kit available).

Weight:

6kg

4

Image 5
Contents XPF XPF Series Dual Output 60V 20A Powerflex DC Power SupplyContact Information Part Number and RevisionTable of Contents Output Specifications SpecificationMeter Specifications Safety Immunity EmissionsConnections InstallationOperation Remote Sensing Connection to the LoadSeries or Parallel connection with other units ProtectionOver-temperature Protection MaintenanceCleaning FuseEquipment Required Access to Calibration AdjustmentsCalibration Current Calibration Voltage CalibrationVoltage Regulation Set OVPAVERTISSEMENT! CET Instrument Doit Etre Relie a LA Terre SécuritéTension d’utilisation secteur ConnexionsCâble secteur MontageOpération Connexion en série ou en parallèle avec d’autres appareils Connexion à la chargeTélédétection Nettoyage Protection contre la surchauffeFusible WARNUNG! Dieses Gerät Muss Geerdet Werden SicherheitNetzbetriebsspannung AnschlüsseNetzkabel BelüftungBetrieb Reihen- und Parallelschaltung mit anderen Geräten VerbraucheranschlussIstwert-Fernerfassung Übertemperaturschutz ÜberspannungsschutzReinigung WartungSicherung Attenzione Questo Strumento Deve Essere Collegato a Terra SicurezzaCollegamento InstallazioneFunzionamento Rilevamento a distanza Allacciamento del caricoCollegamento in serie/parallelo con altre unità ProtezioneProtezione da temperatura eccessiva ManutenzioneFusibile PuliziaADVERTENCIA! Este Instrumento Debe Conectarse a Tierra SeguridadConexiones InstalaciónFuncionamiento Detector remoto Conexión a la cargaConexión en serie o en paralelo a otras unidades ProtecciónLimpieza MantenimientoProtección contra Sobretemperatura How do you get service? Warranty InformationProduct What does this warranty not cover?Xantrex Technology Inc