Xantrex Technology PV-225208 important safety instructions Section Appendix, Inverter States

Page 32

SECTION 7

APPENDIX

Parameters

ID

 

Type

Units

Data Limits

Default

Descriptions

 

 

 

 

 

 

 

 

 

 

Fault Code

3

 

Read

N/A

N/A

N/A

See Fault Codes Above

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter States:

 

 

 

 

 

 

 

 

0-Shut Down

 

Inverter State

4

 

Read

N/A

N/A

N/A

1-Standby

 

 

2-Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-Main-Setting

 

 

 

 

 

 

 

 

4-On-Line

 

 

 

 

 

 

 

 

 

 

Line A-B Voltage

5

 

Read

Vrms

N/A

N/A

Line to Line Voltage

 

 

 

 

 

 

 

 

 

 

Line B-C Voltage

6

 

Read

Vrms

N/A

N/A

Line to Line Voltage

 

 

 

 

 

 

 

 

 

 

Line C-A Voltage

7

 

Read

Vrms

N/A

N/A

Line to Line Voltage

 

 

 

 

 

 

 

 

 

 

Line A Current

8

 

Read

Arms

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

Line B Current

9

 

Read

Arms

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

Line C Current

10

 

Read

Arms

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

Inverter Real Power

11

 

Read

kVA

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

Inverter Matrix

12

 

Read

°C

N/A

N/A

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PV States:

 

 

 

 

 

 

 

 

0-Shut Down

 

PV State

13

 

Read

N/A

N/A

N/A

1-Sleep

 

 

2-Wakeup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-Online

 

 

 

 

 

 

 

 

4-Sleep-Test

 

 

 

 

 

 

 

 

 

 

PV Voltage

14

 

Read

VDC

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

PV Current

15

 

Read

ADC

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

PV Power

16

 

Read

kW

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

Ground Fault Current

17

 

Read

Arms

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

Peak Power On/Off

18

 

Read

N/A

N/A

N/A

0-On

 

 

1-Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter Frequency

19

 

Read

Hz

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

Maximum Inverter

20

 

Read

kVA

N/A

N/A

Maximum Line Power

 

Power

 

Recorded by PCU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOCUMENT: 151811

 

 

PV-225208 Photovoltaic Inverter

7-2

 

 

 

Operation and Maintenance Manual

 

 

Copyright 2003, Xantrex Technology Inc.

Image 32
Contents Manual Table of Contents Operation and Maintenance Manual Section Product Description IntroductionMajor Components Main EnclosureSection Product Description Control ComponentsPower Control Unit PCU Interconnection Standards ComplianceSection Product Description Specifications Equipment SymbolSection Safety Safety Features Main Enclosure Door Interlock SwitchFault Reporting PV Ground Fault DetectionSection Safety Isolation ProcedureOver/Under Voltage and Frequency Anti Island ProtectionTorque and Wire Gauge Specifications Utility Side Isolation Transformer RequirementsInstallation Section Installation and Initial TURN-ONInstallation Instructions Cable Entry Area Array Grounding Interconnection Wiring Ground Fault DetectionPV-225208 Inverter Wiring Diagram Chassis Gnd Transformer PV Array Frame Ground DC InterfaceInterface Circuit BreakerVisual Inspection, PV Array Wiring Initial PowerVisual Inspection, Isolation Transformer WYE/WYE Visual Inspection, PV-225208System Verification Power Tracker Fine Tuning Operating States Section Operation Description of System OperationOverview Operation Features Fixed Unity Power Factor OperationUtility Voltage/Frequency Fault Automatic Reset Section OperationPeak Power Tracking Operator InterfaceCurrent Imbalance Detection DC Overvoltage DetectionSection Operation Commanding Goal State Changes Setting the Date and TimeManual State Transitions Changing Write Parameter ValuesSleeping → Power Tracking → Sleeping Automatic State TransitionsAny State → Fault AUTO-RESTART FeatureTURN-ON Procedure Section Troubleshooting General Alarm and Fault ConditionsSection Troubleshooting Programming Mode SPV Overvoltage S Bad Memory SDoor Interlock Switch Open H PV Auxiliary Switch Open HAC Voltage Too Low S AC Voltage Too High SXX25/XX26 Line Gate Drive Fault S YY27/YY28 Line Over-Current Fault SPV Over-Current Fault S DC Bus Voltage High HSection Preventative Maintenance Periodic Maintenance Section Preventative Maintenance Read-Only Parameters Section Appendix Faults CodesREAD/WRITE Parameter Menu Section Appendix Inverter StatesADC Warranty and Certification Drawings ListXantrex PV Series Limited Warranty and Registration Page Page Page Page Page Fab, Enclosure, Upper, 2 Bay, PV225208 Page Fab, Enclosure, DC Interface, PV225208 Page TB5 Source Control Specification