SECTION 7
APPENDIX
FAULTS CODES
Refer to section 5 for detailed fault code descriptions.
H - Fault(s) triggered by hardware
S - Fault(s) triggered by software
Error | Fault Source(s) | H/S |
| Error | Fault Source(s) | H/S |
Code |
| Code | ||||
|
|
|
|
| ||
|
|
|
|
|
|
|
0000 | No Faults |
|
| 0062 | Line Frequency Too High | (S) |
002C | Matrix | (S) |
| 0063 | Line Voltage Too Low | (S) |
|
|
|
|
|
|
|
002E | State Machine Failure | (S) |
| 0064 | Line Voltage Too High | (S) |
|
|
|
|
|
|
|
002F | Software Parameter Out of Date | (S) |
| 012A | Interrupt | (S) |
|
|
|
|
|
|
|
0031 | Ground Current Fault | (S) |
| 0230 | Door Interlock | (H) |
|
|
|
|
|
|
|
0032 | PV | (S) |
| 0430 | PV Auxiliary Contact Block | (H) |
0040 | In Programming Mode | (S) |
| XX25 | Line Matrix Gate Drive | (S) |
|
|
|
|
|
|
|
0042 | Bad Memory | (S) |
| YY27 | Line Matrix | (S) |
|
|
|
|
|
|
|
0045 | Line Matrix Control Failure to Turn On | (S) |
| 0828 | PV | (S) |
|
|
|
|
|
|
|
0046 | Line Matrix Control Failure to Turn Off | (S) |
| 8021 | DC Bus Voltage Too High | (H) |
|
|
|
|
|
|
|
0061 | Line Frequency Too Low | (S) |
|
|
|
|
|
|
|
|
|
|
|
READ/WRITE PARAMETER MENU
Read-Only Parameters
Parameters | ID | Type | Units | Data Limits | Default |
| Descriptions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Current States: |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Current Operating |
|
|
|
|
|
| |
1 | Read | N/A | N/A | N/A |
| ||
State |
| ||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Goal States: |
|
|
|
|
|
|
| |
System Goal State | 2 | Read | N/A | N/A | N/A |
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DOCUMENT: 151811 |
| ||||||
|
| Operation and Maintenance Manual |
|
Copyright 2003, Xantrex Technology Inc.