Xantrex Technology PV-225208 important safety instructions Fab, Enclosure, Upper, 2 Bay, PV225208

Page 41

Xantrex Technology Inc. PV-225208

Photovoltaic Inverter

Major Parts List

Assembly Description: Main Enclosure, Control Components, PV-225208

Xantrex Technology Assembly # 151808

Item #

Qty

Reference Designator

Xantrex Technology Part #

Description

 

 

 

 

Upper Enclosure

1

1

-

1-151751-01

Fab, Enclosure, Upper, 2 Bay, PV225208

2

1

-

1-151775-01

Assy, PCU, W/Power Supply, PV225208

3

2

-

1-150209-02

Assy, Matrix

4

1

T1

1-151614-01

Transformer, 208:24V, 250VA, 1Phase

5

1

T2

1-151615-01

Transformer, 208:120V, 500VA, 1 Phase

6

3

T3,T4,T5

1-151774-01

Transformer, 2.4V, 5V 1-Phase

7

1

K1

1-150204-03

Contactor, 630A, 3-Phase

8

2

SSR1,SSR2

1-112129-01

SSR, 10A, 240V

9

2

C4,C5

1-111196-01

Capacitor, .15uF, 1000V, Ceramic Disc

10

1

C1

1-151782-01

Capacitor, 10 KVAR, 3P, 600V

11

7

CT1,2,3,4,5,6,8

1-113712-01

CT, Hall Effect, 500A, AC

12

2

B1,B2

1-151187-01

Fan, 1/4 HP, 208VAC, 1-Phase

13

1

B3

1-151023-01

Fan, 120V, 4", Internal

14

1

PS1

1-160006-01

Power Supply, Single Out, +15VDC

15

1

TB4

1-150343-01

Block, Terminal, 2-Pos

16

2

TB2,TB3

1-119154-01

Block, Terminal, 4-Pos, 600V

17

3

F4-12

1-112590-03

Block, Fuse, 600V, 3-Pole

18

1

F13,14

1-112590-01

Block, Fuse, 600V, 2-Pole

19

2

F7,8

1-117452-02

Fuse, 15A, 500VDC

20

4

F9-12

1-117452-07

Fuse, 6A, 500VDC

21

5

F4-6,13,14

1-117452-04

Fuse, 1A, 500VDC

22

1

S6

1-150329-01

Switch, Interlock, Door

23

1

TB1

1-150329-01

Switch, Interlock, Door

24

1

CT7

1-151787-01

Current, Transducer, 1000A

 

 

 

 

Lower Enclosure

25

1

-

1-151750-01

Fab, Enclosure, Lower, 2 Bay, PV225208

26

2

L1,L2

1-151605-01

Reactor, 3PH, 130uH, 312 Arms

27

2

B4,B5

1-151024-01

Fan, 10", 600 CFM

28

2

TS1,TS2

1-151530-02

Thermostat, Disk, Snap, 157 to 169C

 

Qty

Reference Designator

Xantrex Technology Part #

Enclosure Door (Not Shown)

29

1

-

1-151128-02

Assy, LCD, W/Keypad

30

1

S3

1-117906-01

Switch, On/Off, 2 Pole

31

2

-

1-150326-01

Contact Block, NC

151808

Sheet 2 of 2

Image 41
Contents Manual Table of Contents Section Product Description Introduction Operation and Maintenance ManualMajor Components Main EnclosureControl Components Section Product DescriptionInterconnection Standards Compliance Power Control Unit PCUEquipment Symbol Section Product Description SpecificationsMain Enclosure Door Interlock Switch Section Safety Safety FeaturesFault Reporting PV Ground Fault DetectionIsolation Procedure Section SafetyOver/Under Voltage and Frequency Anti Island ProtectionUtility Side Isolation Transformer Requirements Torque and Wire Gauge SpecificationsInstallation Section Installation and Initial TURN-ONInstallation Instructions Cable Entry Area Array Grounding Ground Fault Detection Interconnection WiringPV Array Frame Ground DC Interface PV-225208 Inverter Wiring Diagram Chassis Gnd TransformerInterface Circuit BreakerInitial Power Visual Inspection, PV Array WiringVisual Inspection, Isolation Transformer WYE/WYE Visual Inspection, PV-225208System Verification Power Tracker Fine Tuning Operating States Section Operation Description of System OperationOverview Fixed Unity Power Factor Operation Operation FeaturesUtility Voltage/Frequency Fault Automatic Reset Section OperationOperator Interface Peak Power TrackingCurrent Imbalance Detection DC Overvoltage DetectionSection Operation Setting the Date and Time Commanding Goal State ChangesManual State Transitions Changing Write Parameter ValuesAutomatic State Transitions Sleeping → Power Tracking → SleepingAny State → Fault AUTO-RESTART FeatureTURN-ON Procedure Alarm and Fault Conditions Section Troubleshooting GeneralProgramming Mode S Section TroubleshootingPV Overvoltage S Bad Memory SPV Auxiliary Switch Open H Door Interlock Switch Open HAC Voltage Too Low S AC Voltage Too High SYY27/YY28 Line Over-Current Fault S XX25/XX26 Line Gate Drive Fault SDC Bus Voltage High H PV Over-Current Fault SSection Preventative Maintenance Periodic Maintenance Section Preventative Maintenance Read-Only Parameters Section Appendix Faults CodesREAD/WRITE Parameter Menu Inverter States Section AppendixADC Drawings List Warranty and CertificationXantrex PV Series Limited Warranty and Registration Page Page Page Page Page Fab, Enclosure, Upper, 2 Bay, PV225208 Page Fab, Enclosure, DC Interface, PV225208 Page TB5 Source Control Specification