Xantrex Technology RS232-XHR Features and Functions, Readback Functions, Programmable Functions

Page 14

Features and Specifications

Features and Functions

Features and Functions

Features

Programmable Functions

Readback

Functions

16-bit programming and readback of voltage and current

Programmable soft limits for voltage and current

Programmable over voltage protection with reset

Easy-to-use, self-documenting command set

Standardized commands for complete communication with any of the supplies in the system

User-programmable isolated fault, polarity, isolation, and auxiliary, user-defined output signals.

LED status signals: error, address, remote/local operation, and over voltage protection.

Foldback in CV or CC mode with reset

Software calibration

Output voltage and current

Soft limits for voltage and current

Over voltage protection

Output enable/disable

Maskable fault interrupt

Hold and trigger

Output relay signals

Actual voltage and current

Voltage and current settings

Soft voltage and current limits

Over voltage protection setting

Present and accumulated power supply status

Programming error codes

Fault codes

Power supply model and software version identification

12

Operating Manual for RS-232 for XHR/XFR Series Power Supply

Image 14
Contents RS232-XHR RS232-XFR Page Operating Manual for How do you get service? Phone 604 422 Toll Free North America 800 667 Fax 604 421What does this warranty not cover? Disclaimer Product Information About Your Power Supply Model Number Serial Number Purchased From Purchase DateSafety SupplyMain Sections Manual RevisionsAbout This Manual Contents Calibration Features and Specifications DescriptionFeatures and Specifications Features and FunctionsFeatures Readback FunctionsSpecifications Models 140 12-100 20-60 35-35 40-30Models 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Introduction Initial InspectionInstallation and Configuration Initial InspectionRS-232 Interface Subplate Located on Power Supply Rear Panel RS-232 Interface PCB Basic Setup Procedure Step # Description Action ReferenceBaud Rate Flow Switch Setting ConditionCommunications XON Switch Setting Condition Jumper Connections RS-232 Connector PinPower Supply DCE Host Computer DTE Pin connector Jumper J216 Connections RS-232 Connector PinStartup Switch Position Power on resultsRemote Condition Default Settings Model Example IsetExample Local Lockout CommandRS-232 Connection Power Supply Settings Parameter SettingUser Options and Settings 12 OVP Control Mode SelectionHigh OFF LOW User Signals User Signals J7 ConnectorJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Command Syntax RS-232 OperationOperation FormatParameter Description Form Floating Number Definition ExampleOperation Command Summary Command DescriptionAUXA? Cmode Command Reference Auxa 1 onResponse DLY seconds Lockout. See also Remote/Local Operation on Snsp Remote/Local Operation on Status, and Fault Registers on Section Accumulated Status, Status, and Fault Registers Condition Mnemonic Bit Position Bit Weight 4096Error Codes Error # Error Identification ExplanationTroubleshooting LEDsCalibration Voltage Program Calibration Procedure Voltage Mode CalibrationSetup VoltageVoltage Readback Calibration Procedure Current Program Calibration Procedure Current Mode CalibrationCurrent Calibration Setup Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc