Installation and Configuration

Initial Inspection

J7 User Signal Connector

Error LED (ERR)

Indicates that a programming error has occurred. Clear with error query command.

Address LED (ADR)

Indicates that the unit is being addressed by the master controller.

 

S1 Switch

RS-232 Connector

 

1-1, 2, 3 Baud Rate Selection

 

1-4 Flow ON/OFF Selection

Switch Position Reference

 

1-5 XON Switch

 

markings (0) (1)

 

Hardware/Software Flow Control Selection

 

 

 

Note: On some models, the subplate is rotated 180 degrees.

 

Figure 2.2 RS-232 Interface Subplate

 

 

(Located on Power Supply Rear Panel)

 

CAUTION

Use proper static control techniques to avoid damage to static-sensitive components on the printed circuit board

Release 3.1

21

Image 23
Contents RS232-XHR RS232-XFR Page Operating Manual for Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplySupply SafetyManual Revisions Main SectionsAbout This Manual Contents Calibration Description Features and SpecificationsReadback Functions Features and FunctionsFeatures Features and SpecificationsModels 140 12-100 20-60 35-35 40-30 SpecificationsModels 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Initial Inspection IntroductionInitial Inspection Installation and ConfigurationRS-232 Interface Subplate Located on Power Supply Rear Panel RS-232 Interface PCB Step # Description Action Reference Basic Setup ProcedureBaud Rate Flow Switch Setting ConditionCommunications Jumper Connections RS-232 Connector Pin XON Switch Setting ConditionJumper J216 Connections RS-232 Connector Pin Power Supply DCE Host Computer DTE Pin connectorStartup Switch Position Power on resultsRemote Iset Condition Default Settings Model ExampleExample Local Lockout CommandRS-232 Connection Parameter Setting Power Supply Settings12 OVP Control Mode Selection User Options and SettingsHigh OFF LOW User Signals J7 Connector User SignalsJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block RS-232 Operation Command SyntaxFormat OperationFloating Number Definition Example Parameter Description FormOperation Command Description Command SummaryAUXA? Cmode Auxa 1 on Command ReferenceResponse DLY seconds Lockout. See also Remote/Local Operation on Snsp Remote/Local Operation on Status, and Fault Registers on Section Accumulated Status, Status, and Fault Registers 4096 Condition Mnemonic Bit Position Bit WeightError # Error Identification Explanation Error CodesLEDs TroubleshootingCalibration Voltage Voltage Mode CalibrationSetup Voltage Program Calibration ProcedureVoltage Readback Calibration Procedure Current Program Calibration Procedure Current Mode CalibrationCurrent Calibration Setup Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc