Xantrex Technology RS232-XHR manual Models 130 20-50 33-33 40-25 60-18

Page 19

Features and Specifications

Specifications

Table 1.5 Specifications for XHR 1000 W Series Supply with RS-232 Interface Installed (7.5 V to 60 V)

Models

7.5-130

20-50

33-33

40-25

60-18

Program Resolution

1.2mV

3.1mV

5.1mV

6.2mV

9.3mV

Voltage

Current

18.3mA

7.1mA

4.7mA

3.6mA

2.6mA

OVP

1.2mV

3.1mV

5.1mV

6.2mV

9.3mV

Program Accuracy1

 

 

 

 

 

Voltage

10mV

75mV

75mV

75mV

150mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.25%

Current

500mA

250mA

165mA

140mA

120mA

 

±0.1%

±0.1%

±0.1%

±0.15%

±0.1%

OVP

80mV

200mV

330mV

400mV

600mV

Readback Resolution

 

 

 

 

 

Voltage

1.2mV

3.1mV

5.1mV

6.2mV

9.3mV

Current

18.3mA

7.1mA

4.7mA

3.6mA

2.6mA

Readback Accuracy1

 

 

 

 

 

Voltage

30mV

75mV

75mV

75mV

150mV

 

±0.12%

±0.12%

±0.2%

±0.3%

±0.25%

Current

500mA

250mA

165mA

140mA

120mA

 

±0.1%

±0.1%

±0.15%

±0.15%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-50 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.

Release 3.1

17

Image 19
Contents RS232-XHR RS232-XFR Page Operating Manual for Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplySupply SafetyManual Revisions Main SectionsAbout This Manual Contents Calibration Description Features and SpecificationsReadback Functions Features and FunctionsFeatures Features and SpecificationsModels 140 12-100 20-60 35-35 40-30 SpecificationsModels 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Initial Inspection IntroductionInitial Inspection Installation and ConfigurationRS-232 Interface Subplate Located on Power Supply Rear Panel RS-232 Interface PCB Step # Description Action Reference Basic Setup ProcedureCommunications Flow Switch Setting ConditionBaud Rate Jumper Connections RS-232 Connector Pin XON Switch Setting ConditionJumper J216 Connections RS-232 Connector Pin Power Supply DCE Host Computer DTE Pin connectorRemote Switch Position Power on resultsStartup Iset Condition Default Settings Model ExampleExample RS-232 Connection CommandLocal Lockout Parameter Setting Power Supply Settings12 OVP Control Mode Selection User Options and SettingsHigh OFF LOW User Signals J7 Connector User SignalsJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block RS-232 Operation Command SyntaxFormat OperationFloating Number Definition Example Parameter Description FormOperation Command Description Command SummaryAUXA? Cmode Auxa 1 on Command ReferenceResponse DLY seconds Lockout. See also Remote/Local Operation on Snsp Remote/Local Operation on Status, and Fault Registers on Section Accumulated Status, Status, and Fault Registers 4096 Condition Mnemonic Bit Position Bit WeightError # Error Identification Explanation Error CodesLEDs TroubleshootingCalibration Voltage Voltage Mode CalibrationSetup Voltage Program Calibration ProcedureVoltage Readback Calibration Procedure Current Calibration Setup Current Mode CalibrationCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc