Fujitsu RX200 manual Installation and operation

Page 18

Safety Instructions

Installation and operation

VCAUTION!

If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.

The server automatically adjusts to a mains voltage between 100 V and 240 V. Make sure that the local mains voltage is neither above nor below this range.

This device has safety-tested power cables and must only be connected to properly grounded power outlets.

Make sure that the power socket on the device or the grounded mains outlet is freely accessible.

The power switch does not disconnect the device from the mains voltage. To completely disconnect it from the mains voltage, you must remove the power plug from the power outlet.

Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, a power outage occurs and the central processing unit is still running but the peripheral device (e.g. a storage subsystem) has failed.

Data cables must be adequately shielded to avoid interference.

For the LAN wiring, the requirements according to standards EN 50173 and EN 50174-1/2 apply. The minimum requirement is the use of a protected LAN line of category 5 for 10/100 Mbps Ethernet, and/or of category 5e for Gigabit Ethernet. The requirements of the specification ISO/IEC 11801 must also be taken into account.

Route the cables in such a way that they do not form a potential hazard (tripping) and that they cannot be damaged. When connecting the device, refer to the relevant notes in the operating manual.

Do not connect or disconnect any data transmission cables during a thunderstorm (lightning hazard).

10

OptionsGuide

Image 18
Contents Primergy RX200 S2 Serversystem Comments… Suggestions… Corrections… Certified documentation according to DIN EN ISOPage Page Abbreviations Related publications Index Page Contents Page Concept and target groups PrefaceOverview of the documentation Additional documentation about the serverOverview of the documentation Preface Further sources of informationSecond processor Additional accessible drivesExtensions and conversions Extension of the main memoryRemoteView Service Board S2 LP RemoteViewNotational conventions Page Procedure Page Safety Instructions Before setting upInstallation and operation Page Batteries Modules with electrostatic-sensitive devices ESD labelPage Preparation Opening the serverOpening the server Removing the coverInstallation rules Main MemoryUpgrading / exchanging main memory Upgrading / exchanging main memoryInstalling a second processor ProcessorsInstalling a second processor Removing the ventilation ductInstalling the processor ProcessorsRemoving the heat sink dummy Vcaution Installing the heat sink Installing the ventilation ductExchanging the processor Exchanging the processorExchanging the processor Exchanging the processor Exchanging the heat sink Page Accessible Drives Installing the LocalView Module Installing the LocalView ModuleAccessible Drives Connecting the LocalView moduleInstalling a CD-ROM/DVD drive Installing a CD-ROM/DVD driveRemoving the dummy cover Installing a CD-ROM/DVD drive Installing the CD-ROM/DVD drive Installing a floppy disk drive Installing a floppy disk drive Removing/installing a floppy disk driveConnecting the data cable Page Controllers in Non-Hot-Plug PCI Slots Installing a PCI board Installing controllersInstalling controllers Removing the riser card holderReinstalling the riser card holder Mounting the boardPage Installing the RemoteView Service Board S2 LP RemoteView ComponentsRemove the slot cover Completion Closing the serverInstalling the server Closing the serverAbbreviations Abbreviations GAM LVD Rtds Page Related publications Integrated Mirroring User’s Guide Index Upgrade Comments Suggestions Corrections Page Comments Suggestions Corrections