Fujitsu RX200 manual Modules with electrostatic-sensitive devices, ESD label

Page 21

Safety Instructions

ITo protect the CD-ROM/DVD drive and prevent mechanical damage, as well as premature wearing of the CDs, you should observe the following advice:

Only insert the CDs in the drive when needed and remove them after use.

Store the CDs in suitable sleeves.

Protect the CDs from exposure to heat and direct sunlight.

Note on the laser

The CD-ROM/DVD drive contains a light-emitting diode (LED) classified according to IEC 825-1:1993:LASER CLASS 1.

Modules with electrostatic-sensitive devices

Electrostatic-sensitive components are identified by the following sticker:

Figure 1: ESD label

VCAUTION!

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

Remove the power plug from the power socket before inserting or removing components containing ESDs.

You must always discharge static build-up (e.g. by touching a grounded object) before working with such components.

The equipment and tools you use must be free of static charge.

Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

OptionsGuide

13

Image 21
Contents Primergy RX200 S2 Serversystem Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Page Page Abbreviations Related publications Index Page Contents Page Overview of the documentation PrefaceConcept and target groups Additional documentation about the serverFurther sources of information Overview of the documentation PrefaceExtensions and conversions Additional accessible drivesSecond processor Extension of the main memoryRemoteView RemoteView Service Board S2 LPNotational conventions Page Procedure Page Before setting up Safety InstructionsInstallation and operation Page Batteries ESD label Modules with electrostatic-sensitive devicesPage Opening the server PreparationRemoving the cover Opening the serverMain Memory Installation rulesUpgrading / exchanging main memory Upgrading / exchanging main memoryProcessors Installing a second processorRemoving the ventilation duct Installing a second processorInstalling the processor ProcessorsRemoving the heat sink dummy Vcaution Installing the ventilation duct Installing the heat sinkExchanging the processor Exchanging the processorExchanging the processor Exchanging the processor Exchanging the heat sink Page Accessible Drives Installing the LocalView Module Installing the LocalView ModuleConnecting the LocalView module Accessible DrivesInstalling a CD-ROM/DVD drive Installing a CD-ROM/DVD driveRemoving the dummy cover Installing a CD-ROM/DVD drive Installing the CD-ROM/DVD drive Installing a floppy disk drive Removing/installing a floppy disk drive Installing a floppy disk driveConnecting the data cable Page Controllers in Non-Hot-Plug PCI Slots Installing controllers Installing controllersInstalling a PCI board Removing the riser card holderMounting the board Reinstalling the riser card holderPage RemoteView Components Installing the RemoteView Service Board S2 LPRemove the slot cover Closing the server CompletionClosing the server Installing the serverAbbreviations Abbreviations GAM LVD Rtds Page Related publications Integrated Mirroring User’s Guide Index Upgrade Comments Suggestions Corrections Page Comments Suggestions Corrections