Fujitsu RX200 manual Processors, Removing the heat sink dummy, Installing the processor

Page 29

Processors

Installing a second processor

Removing the heat sink dummy

Figure 7: Removing the heat sink dummy

ÊRemove the heat sink dummy.

Installing the processor

Figure 8: Opening the socket lever

ÊRelease the socket lever by pressing it sideways and lifting it up as far as it will go.

OptionsGuide

21

Image 29
Contents Primergy RX200 S2 Serversystem Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Page Page Abbreviations Related publications Index Page Contents Page Overview of the documentation PrefaceConcept and target groups Additional documentation about the serverFurther sources of information Overview of the documentation PrefaceExtensions and conversions Additional accessible drivesSecond processor Extension of the main memoryRemoteView RemoteView Service Board S2 LPNotational conventions Page Procedure Page Before setting up Safety InstructionsInstallation and operation Page Batteries ESD label Modules with electrostatic-sensitive devicesPage Opening the server PreparationRemoving the cover Opening the serverMain Memory Installation rulesUpgrading / exchanging main memory Upgrading / exchanging main memoryProcessors Installing a second processorRemoving the ventilation duct Installing a second processorRemoving the heat sink dummy Installing the processorProcessors Vcaution Installing the ventilation duct Installing the heat sinkExchanging the processor Exchanging the processorExchanging the processor Exchanging the processor Exchanging the heat sink Page Accessible Drives Installing the LocalView Module Installing the LocalView ModuleConnecting the LocalView module Accessible DrivesRemoving the dummy cover Installing a CD-ROM/DVD driveInstalling a CD-ROM/DVD drive Installing a CD-ROM/DVD drive Installing the CD-ROM/DVD drive Installing a floppy disk drive Removing/installing a floppy disk drive Installing a floppy disk driveConnecting the data cable Page Controllers in Non-Hot-Plug PCI Slots Installing controllers Installing controllersInstalling a PCI board Removing the riser card holderMounting the board Reinstalling the riser card holderPage RemoteView Components Installing the RemoteView Service Board S2 LPRemove the slot cover Closing the server CompletionClosing the server Installing the serverAbbreviations Abbreviations GAM LVD Rtds Page Related publications Integrated Mirroring User’s Guide Index Upgrade Comments Suggestions Corrections Page Comments Suggestions Corrections