Fujitsu RX200 manual

Page 22

Safety Instructions

VCAUTION!

Always hold components with ESDs at the points marked green (touch points).

Do not touch any exposed pins or conductors on a component.

Place all components on a static-free base.

IYou will find a detailed description of handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

14

OptionsGuide

Image 22
Contents Primergy RX200 S2 Serversystem Comments… Suggestions… Corrections… Certified documentation according to DIN EN ISOPage Page Abbreviations Related publications Index Page Contents Page Concept and target groups PrefaceOverview of the documentation Additional documentation about the serverOverview of the documentation Preface Further sources of informationSecond processor Additional accessible drivesExtensions and conversions Extension of the main memoryRemoteView Service Board S2 LP RemoteViewNotational conventions Page Procedure Page Safety Instructions Before setting upInstallation and operation Page Batteries Modules with electrostatic-sensitive devices ESD labelPage Preparation Opening the serverOpening the server Removing the coverInstallation rules Main MemoryUpgrading / exchanging main memory Upgrading / exchanging main memoryInstalling a second processor ProcessorsInstalling a second processor Removing the ventilation ductProcessors Installing the processorRemoving the heat sink dummy Vcaution Installing the heat sink Installing the ventilation ductExchanging the processor Exchanging the processorExchanging the processor Exchanging the processor Exchanging the heat sink Page Accessible Drives Installing the LocalView Module Installing the LocalView ModuleAccessible Drives Connecting the LocalView moduleInstalling a CD-ROM/DVD drive Installing a CD-ROM/DVD driveRemoving the dummy cover Installing a CD-ROM/DVD drive Installing the CD-ROM/DVD drive Installing a floppy disk drive Installing a floppy disk drive Removing/installing a floppy disk driveConnecting the data cable Page Controllers in Non-Hot-Plug PCI Slots Installing a PCI board Installing controllersInstalling controllers Removing the riser card holderReinstalling the riser card holder Mounting the boardPage Installing the RemoteView Service Board S2 LP RemoteView ComponentsRemove the slot cover Completion Closing the serverInstalling the server Closing the serverAbbreviations Abbreviations GAM LVD Rtds Page Related publications Integrated Mirroring User’s Guide Index Upgrade Comments Suggestions Corrections Page Comments Suggestions Corrections