Fujitsu RX200 manual Gam

Page 57

Abbreviations

GAM

Global Array Manager

GUI

Graphical User Interface

HDD

Hard Disk Drive

HSC

Hot-Swap Controller

I²C

Inter-Integrated Circuit

I/O

Input/Output

ICM

Intelligent Chassis Management

ID

Identification

IDE

Integrated Drive Electronics

IRQ

Interrupt Request Line

LAN

Local Area Network

LBA

Logical Block Address

LCD

Liquid Crystal Display

LUN

Logical Unit Number

OptionsGuide

49

Image 57
Contents Primergy RX200 S2 Serversystem Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Page Page Abbreviations Related publications Index Page Contents Page Overview of the documentation PrefaceConcept and target groups Additional documentation about the serverFurther sources of information Overview of the documentation PrefaceExtensions and conversions Additional accessible drivesSecond processor Extension of the main memoryRemoteView RemoteView Service Board S2 LPNotational conventions Page Procedure Page Before setting up Safety InstructionsInstallation and operation Page Batteries ESD label Modules with electrostatic-sensitive devicesPage Opening the server PreparationRemoving the cover Opening the serverMain Memory Installation rulesUpgrading / exchanging main memory Upgrading / exchanging main memoryProcessors Installing a second processorRemoving the ventilation duct Installing a second processorInstalling the processor ProcessorsRemoving the heat sink dummy Vcaution Installing the ventilation duct Installing the heat sinkExchanging the processor Exchanging the processorExchanging the processor Exchanging the processor Exchanging the heat sink Page Accessible Drives Installing the LocalView Module Installing the LocalView ModuleConnecting the LocalView module Accessible DrivesInstalling a CD-ROM/DVD drive Installing a CD-ROM/DVD driveRemoving the dummy cover Installing a CD-ROM/DVD drive Installing the CD-ROM/DVD drive Installing a floppy disk drive Removing/installing a floppy disk drive Installing a floppy disk driveConnecting the data cable Page Controllers in Non-Hot-Plug PCI Slots Installing controllers Installing controllersInstalling a PCI board Removing the riser card holderMounting the board Reinstalling the riser card holderPage RemoteView Components Installing the RemoteView Service Board S2 LPRemove the slot cover Closing the server CompletionClosing the server Installing the serverAbbreviations Abbreviations GAM LVD Rtds Page Related publications Integrated Mirroring User’s Guide Index Upgrade Comments Suggestions Corrections Page Comments Suggestions Corrections