Fujitsu RX200 manual Connecting the data cable

Page 45

Accessible Drives

Installing a floppy disk drive

 

 

 

 

 

 

Figure 21: Connecting the data cable

ÊRemove the capton foil from the data cable and connect the cable to the rear of the floppy drive (see figure).

ÊClose the server, plug in the power plugs, and switch on the server as described in the chapter “Completion” on page 45f.

OptionsGuide

37

Image 45
Contents Primergy RX200 S2 Serversystem Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Page Page Abbreviations Related publications Index Page Contents Page Overview of the documentation PrefaceConcept and target groups Additional documentation about the serverFurther sources of information Overview of the documentation PrefaceExtensions and conversions Additional accessible drivesSecond processor Extension of the main memoryRemoteView RemoteView Service Board S2 LPNotational conventions Page Procedure Page Before setting up Safety InstructionsInstallation and operation Page Batteries ESD label Modules with electrostatic-sensitive devicesPage Opening the server PreparationRemoving the cover Opening the serverMain Memory Installation rulesUpgrading / exchanging main memory Upgrading / exchanging main memoryProcessors Installing a second processorRemoving the ventilation duct Installing a second processorInstalling the processor ProcessorsRemoving the heat sink dummy Vcaution Installing the ventilation duct Installing the heat sinkExchanging the processor Exchanging the processorExchanging the processor Exchanging the processor Exchanging the heat sink Page Accessible Drives Installing the LocalView Module Installing the LocalView ModuleConnecting the LocalView module Accessible DrivesInstalling a CD-ROM/DVD drive Installing a CD-ROM/DVD driveRemoving the dummy cover Installing a CD-ROM/DVD drive Installing the CD-ROM/DVD drive Installing a floppy disk drive Removing/installing a floppy disk drive Installing a floppy disk driveConnecting the data cable Page Controllers in Non-Hot-Plug PCI Slots Installing controllers Installing controllersInstalling a PCI board Removing the riser card holderMounting the board Reinstalling the riser card holderPage RemoteView Components Installing the RemoteView Service Board S2 LPRemove the slot cover Closing the server CompletionClosing the server Installing the serverAbbreviations Abbreviations GAM LVD Rtds Page Related publications Integrated Mirroring User’s Guide Index Upgrade Comments Suggestions Corrections Page Comments Suggestions Corrections