5.2Upgrading / exchanging main memory

ÊOpen the server as described in the chapter “Preparation” on page 15f.

2

1

1

Figure 4: Removing a memory module

ÊFlip the ejector tabs on each side of the slot outward (1). This levers an installed memory module out of its slot.

ÊRemove the memory module from the slot (2).

2

2

Figure 5: Installing a memory module

ÊCarefully press the memory module into the slot (1) until the ejector tabs on both sides of it engage (2).

ÊClose the server, plug in the power plugs, and switch on the server as described in the chapter “Completion” on page 45f.

18

OptionsGuide

Image 26
Contents Primergy RX200 S2 Serversystem Comments… Suggestions… Corrections… Certified documentation according to DIN EN ISOPage Page Abbreviations Related publications Index Page Contents Page Concept and target groups PrefaceOverview of the documentation Additional documentation about the serverOverview of the documentation Preface Further sources of informationSecond processor Additional accessible drivesExtensions and conversions Extension of the main memoryRemoteView Service Board S2 LP RemoteViewNotational conventions Page Procedure Page Safety Instructions Before setting upInstallation and operation Page Batteries Modules with electrostatic-sensitive devices ESD labelPage Preparation Opening the serverOpening the server Removing the coverInstallation rules Main MemoryUpgrading / exchanging main memory Upgrading / exchanging main memoryInstalling a second processor ProcessorsInstalling a second processor Removing the ventilation ductRemoving the heat sink dummy Installing the processorProcessors Vcaution Installing the heat sink Installing the ventilation ductExchanging the processor Exchanging the processorExchanging the processor Exchanging the processor Exchanging the heat sink Page Accessible Drives Installing the LocalView Module Installing the LocalView ModuleAccessible Drives Connecting the LocalView moduleRemoving the dummy cover Installing a CD-ROM/DVD driveInstalling a CD-ROM/DVD drive Installing a CD-ROM/DVD drive Installing the CD-ROM/DVD drive Installing a floppy disk drive Installing a floppy disk drive Removing/installing a floppy disk driveConnecting the data cable Page Controllers in Non-Hot-Plug PCI Slots Installing a PCI board Installing controllersInstalling controllers Removing the riser card holderReinstalling the riser card holder Mounting the boardPage Installing the RemoteView Service Board S2 LP RemoteView ComponentsRemove the slot cover Completion Closing the serverInstalling the server Closing the serverAbbreviations Abbreviations GAM LVD Rtds Page Related publications Integrated Mirroring User’s Guide Index Upgrade Comments Suggestions Corrections Page Comments Suggestions Corrections