Fujitsu Siemens Computers S60 manual Optical Waveguide Color Meaning

Page 25

Operating and Indicator Elements

The Front

 

 

 

Optical Waveguide

Color

Meaning

 

 

 

Power supply status

none

No mains voltage present.

 

 

 

 

green

POWER OK

 

 

Equipment switched ON, all installed

 

 

power supply units OK.

 

 

 

 

yellow

POWER WARNING

 

 

One power supply unit has failed.

 

 

 

 

orange

STANDBY

 

 

Equipment switched OFF, mains voltage

 

 

present.

 

 

 

Cooling status

green

Cooling OK

VCAUTION!

 

All installed fans and the interior temper-

 

ature are OK.

The PRIMERGY S60

yellow

Fan warning

 

One fan has failed.

storage subsystem

 

 

The temperature is OK.

(without Remote Service

 

 

 

orange

Cooling fault

Board) switches OFF at

 

All the fans have failed or the interior

an interior temperature of

 

 

temperature exceeds the permissible

55°C (see section

 

 

values.

“Cooling status LED lights

 

 

 

orange” on page 73).

 

 

 

 

 

Server management

none

No status indication

status (global SES

 

 

orange

Identification indication

indicator)

 

(can be activated manually from

 

 

 

 

ServerView).

 

 

For troubleshooting see section “Server

 

 

Management Status LED lights perma-

 

 

nently” on page 74.

 

 

 

Table 1: Meaning of the Operating Status LEDs Indication

U41221-J-Z156-1-74

17

Image 25
Contents Primergy S60 Storage Subsystem Copyright and Trademarks Comments… Suggestions… Corrections…German English Page Contents Plug-in Board Modules ContentsContents Page Server Management/ServerView IntroductionNotation Conventions Target GroupTarget Group BoldStructure of the Manual Technical Data Environmental Conditions according to DIN EN Maintenance Areas and Ventilation DistancesStandards Complied With Noise Development ISO Operation IdlePage Important Notes Important Notes Electrostatic Sensitive Device ESD sticker Electrostatic Sensitive Device LabelRFI Suppression CE certificateFCC notices Federal Communications Commission CE certificateImportant Notes Environmental Protection Environmental ProtectionEnvironmentally friendly product design and development Further information on environmental protection Take-back, recycling and disposalPage Front Operating and Indicator ElementsFront Meaning of the S60 Operating Status LEDsOptical Waveguide Color Meaning Hddstatus Control LEDs for the Hard Disk DrivesIndication Meaning LEDFFx-RAID Controller Module LEDs Rear SideRear Side Fault Operating Status of the power supply unit Power Supply Unit LEDsSetting Power SwitchPosition Function Description Color Meaning Required Measures Fan LEDPage Floorstand Model Open the HousingRemoving and Mounting the door Removing/Mounting the left Side Cover Open the HousingOpen the Housing Page Power Supply Units Power SupplyPower Supply Units Replacing the Power Supply UnitInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page Handling Hard Disk Drives/HDD Modules FC Hard Disk DrivesInstalling/Removing HDD/Dummy Module Installing/Removing HDD/Dummy ModuleRemoving the dummy module FC Hard Disk Drives Installing the HDD moduleHours Temperature difference C Minimum acclimatization timeRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page FFx-RAID Controller Module Plug-in Board ModulesFFx-RAID Controller Module Indicators and ConnectorsElement Label on the connection panel DACRed Description of the LED indicatorsHssdc RS232 Switch SwitchesPos. Description FFx-RAID Controller Module Switches on the Host Adapter DIP SwitchesDIP switch Function Installing/removing the FFx-RAID controller moduleLoosen the knurled screw on the FFx-RAID controller module Removing the Module Adding a Second FFx-RAID Controller ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Terminals on the Rear Panel ConnectionsMains Connection Fibre Channel FC ConnectionFibre Channel FC Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Steps InstallationUnpacking the Storage Subsystem Setting Up the Floorstand ModelUnpacking the Storage Subsystem Mounting the Rack Model Mounting the Rack Model Preparing the Slide RailsMounting the Subsystem Mounting Slide RailsLeads Routing Routing the CablesArticulated Cable Guide Connecting and Disconnecting Cables Connecting and Disconnecting CablesConnecting leads Disconnecting leadsSwitching the Storage Subsystem ON/OFF Page Problem Solutions and Tips TroubleshootingPower Supply Status Indicator Front Power supply status indicator lights orange Power supply status indicator lights yellowCooling status LED lights yellow Cooling StatusOne of the fans is defective Cooling status LED lights orangeServer Management Status System will not boot after Installation of New HDD Modules Storage Subsystem Switches OFFHDD Ready Indicator does not light up Configuration of the FFx-RAID controller incorrect Problem Solutions and Tips TroubleshootingFFx-RAID controller not configured for the hard disk drive Hard Disk Drives dead on System StartAbbreviations IEC SCA Page Primergy S60 Related publicationsPage Cables IndexIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections

S60 specifications

Fujitsu Siemens Computers S60 is a notable offering from the collaboration between Fujitsu and Siemens, aimed at delivering high performance in the realm of desktop computing. Launched in the early 2000s, the S60 series represents a sophisticated blend of technology and design, appealing to both business users and tech enthusiasts alike.

One of the main features of the Fujitsu Siemens S60 is its robust hardware architecture. The system typically came equipped with Intel processors, ranging from Pentium 4 to Core 2 Duo, enabling seamless multitasking and efficient performance for various applications. With support for varying amounts of RAM, generally from 512MB to 4GB, the S60 catered to different user needs, whether for basic office tasks or more demanding software environments.

Storage options were versatile, featuring both traditional hard drives and the emerging SSD technology, allowing users to choose between speed and larger storage capacity. The inclusion of multiple USB ports facilitated easy connectivity with peripherals, such as printers, external drives, and various multimedia devices.

In terms of display technology, the Fujitsu Siemens S60 was compatible with a variety of monitors, including LCD displays which offered improved clarity and energy efficiency over traditional CRTs. The desktop's graphics capabilities were enhanced by integrated solutions from Intel, which provided adequate performance for standard business applications without needing a dedicated graphics card.

Another key characteristic is the emphasis on energy efficiency and eco-friendliness. Fujitsu Siemens prioritized the development of systems that met environmental standards, helping to minimize the carbon footprint of their products. This commitment is evident in their Energy Star-compliant designs, which aimed to reduce power consumption during operation.

The S60 series also featured various connectivity options, including Ethernet for network access and, in later models, wireless capabilities, giving users the flexibility to connect to the internet and enterprise resources effortlessly.

Adopting a modular design approach, the Fujitsu Siemens S60 made upgrades straightforward. Users could easily swap out components such as RAM, hard drives, and graphics cards, making the system highly adaptable to evolving technology needs.

Overall, the Fujitsu Siemens Computers S60 provided a comprehensive solution for users seeking a balanced combination of performance, expandability, and sustainability, making it a popular choice during its time. With its feature-rich specifications and forward-thinking design, the S60 left a lasting impression on the desktop computing landscape.