Fujitsu Siemens Computers S60 manual Index, Cables

Page 91

Index

A

AC power distribution 58 acclimatization time 40, 61 adhesive labels on plastic casing

parts 12 approval certification 5

B

batteries, disposal 12 battery

conditioning 56 longevity 56

Battery Backup Unit 56

C cables

connecting 68 disconnecting 68

CE label 5, 10 connections

FC connection 58 main connection 58

consumables 12 cooling

fan module 33 cooling status LED

lights orange 73 lights yellow 73

D

disposal of equipment 13

E

electrical data 4

electromagnetic compatibility 5, 10 EMC 39

EMC guideline 5 emitted interference 5 environmental conditions 5 environmental protection 12 ergonomics 5

F

fan LED 23, 33 fan module 33 removal 34

replacement 33 FC connection 58 FCC notices 10 FFx-RAID controller module

adding 54 BBU 56 channel activity 49 connectors 47 device adapter 45 DIP switch 51 FC-HUB 46

FFx-RAID controller 45 GBIC 47

Host adapter 45 hot swap 47 HSSDC connector 47 indicators 47 installing 52

node status indicators 49 removing 52

RS232 status indicators 50 RS232 switch 50

status indicators 48 status LEDs 20 VT100/Debug connector 47

floorstand model housing opening 25 setting up 62

side cover 26

H

hard disk drive “dead” 76 handling 37, 42 HDD module 37 hot swap 37, 42 LED does not light 75

U41221-J-Z156-1-74

83

Image 91
Contents Primergy S60 Storage Subsystem Copyright and Trademarks Comments… Suggestions… Corrections…German English Page Contents Plug-in Board Modules ContentsContents Page Server Management/ServerView IntroductionBold Target GroupNotation Conventions Target GroupStructure of the Manual Technical Data Noise Development ISO Operation Idle Maintenance Areas and Ventilation DistancesEnvironmental Conditions according to DIN EN Standards Complied WithPage Important Notes Important Notes Electrostatic Sensitive Device ESD sticker Electrostatic Sensitive Device LabelCE certificate CE certificateRFI Suppression FCC notices Federal Communications CommissionImportant Notes Environmental Protection Environmental ProtectionEnvironmentally friendly product design and development Further information on environmental protection Take-back, recycling and disposalPage Front Operating and Indicator ElementsFront Meaning of the S60 Operating Status LEDsOptical Waveguide Color Meaning Hddstatus Control LEDs for the Hard Disk DrivesIndication Meaning LEDFFx-RAID Controller Module LEDs Rear SideRear Side Fault Operating Status of the power supply unit Power Supply Unit LEDsSetting Power SwitchPosition Function Description Color Meaning Required Measures Fan LEDPage Floorstand Model Open the HousingRemoving and Mounting the door Removing/Mounting the left Side Cover Open the HousingOpen the Housing Page Power Supply Units Power SupplyPower Supply Units Replacing the Power Supply UnitInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page Handling Hard Disk Drives/HDD Modules FC Hard Disk DrivesInstalling/Removing HDD/Dummy Module Installing/Removing HDD/Dummy ModuleRemoving the dummy module FC Hard Disk Drives Installing the HDD moduleHours Temperature difference C Minimum acclimatization timeRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page FFx-RAID Controller Module Plug-in Board ModulesFFx-RAID Controller Module Indicators and ConnectorsElement Label on the connection panel DACRed Description of the LED indicatorsHssdc RS232 Switch SwitchesPos. Description FFx-RAID Controller Module Switches on the Host Adapter DIP SwitchesDIP switch Function Installing/removing the FFx-RAID controller moduleLoosen the knurled screw on the FFx-RAID controller module Removing the Module Adding a Second FFx-RAID Controller ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Terminals on the Rear Panel ConnectionsMains Connection Fibre Channel FC ConnectionFibre Channel FC Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Steps InstallationUnpacking the Storage Subsystem Setting Up the Floorstand ModelUnpacking the Storage Subsystem Mounting the Rack Model Mounting the Rack Model Preparing the Slide RailsMounting the Subsystem Mounting Slide RailsLeads Routing Routing the CablesArticulated Cable Guide Disconnecting leads Connecting and Disconnecting CablesConnecting and Disconnecting Cables Connecting leadsSwitching the Storage Subsystem ON/OFF Page Problem Solutions and Tips TroubleshootingPower Supply Status Indicator Front Power supply status indicator lights orange Power supply status indicator lights yellowCooling status LED lights orange Cooling StatusCooling status LED lights yellow One of the fans is defectiveServer Management Status System will not boot after Installation of New HDD Modules Storage Subsystem Switches OFFHDD Ready Indicator does not light up Hard Disk Drives dead on System Start Problem Solutions and Tips TroubleshootingConfiguration of the FFx-RAID controller incorrect FFx-RAID controller not configured for the hard disk driveAbbreviations IEC SCA Page Primergy S60 Related publicationsPage Cables IndexIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections