Fujitsu Siemens Computers S60 manual Comments Suggestions Corrections

Page 95

Fujitsu Siemens Computers GmbH

User Documentation

81730 München

Germany

Fax: 0 700 / 372 00000

email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com

Comments

Suggestions

Corrections

Submitted by

Comments on PRIMERGY S60

Storage Subsystem

U41221-J-Z156-1-74

Image 95
Contents Primergy S60 Storage Subsystem Copyright and Trademarks Comments… Suggestions… Corrections…German English Page Contents Plug-in Board Modules ContentsContents Page Server Management/ServerView IntroductionBold Target GroupNotation Conventions Target GroupStructure of the Manual Technical Data Noise Development ISO Operation Idle Maintenance Areas and Ventilation DistancesEnvironmental Conditions according to DIN EN Standards Complied WithPage Important Notes Important Notes Electrostatic Sensitive Device ESD sticker Electrostatic Sensitive Device LabelCE certificate CE certificateRFI Suppression FCC notices Federal Communications CommissionImportant Notes Environmentally friendly product design and development Environmental ProtectionEnvironmental Protection Further information on environmental protection Take-back, recycling and disposalPage Front Operating and Indicator ElementsFront Meaning of the S60 Operating Status LEDsOptical Waveguide Color Meaning Hddstatus Control LEDs for the Hard Disk DrivesIndication Meaning LEDRear Side Rear SideFFx-RAID Controller Module LEDs Fault Operating Status of the power supply unit Power Supply Unit LEDsPosition Function Description Power SwitchSetting Color Meaning Required Measures Fan LEDPage Removing and Mounting the door Open the HousingFloorstand Model Removing/Mounting the left Side Cover Open the HousingOpen the Housing Page Power Supply Units Power SupplyPower Supply Units Replacing the Power Supply UnitInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page Handling Hard Disk Drives/HDD Modules FC Hard Disk DrivesRemoving the dummy module Installing/Removing HDD/Dummy ModuleInstalling/Removing HDD/Dummy Module FC Hard Disk Drives Installing the HDD moduleHours Temperature difference C Minimum acclimatization timeRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page FFx-RAID Controller Module Plug-in Board ModulesFFx-RAID Controller Module Indicators and ConnectorsElement Label on the connection panel DACRed Description of the LED indicatorsHssdc Pos. Description SwitchesRS232 Switch FFx-RAID Controller Module Switches on the Host Adapter DIP SwitchesDIP switch Function Installing/removing the FFx-RAID controller moduleLoosen the knurled screw on the FFx-RAID controller module Removing the Module Adding a Second FFx-RAID Controller ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Terminals on the Rear Panel ConnectionsFibre Channel FC Connection Fibre Channel FC ConnectionMains Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Steps InstallationUnpacking the Storage Subsystem Setting Up the Floorstand ModelUnpacking the Storage Subsystem Mounting the Rack Model Mounting the Rack Model Preparing the Slide RailsMounting the Subsystem Mounting Slide RailsLeads Routing Routing the CablesArticulated Cable Guide Disconnecting leads Connecting and Disconnecting CablesConnecting and Disconnecting Cables Connecting leadsSwitching the Storage Subsystem ON/OFF Page Power Supply Status Indicator Front TroubleshootingProblem Solutions and Tips Power supply status indicator lights orange Power supply status indicator lights yellowCooling status LED lights orange Cooling StatusCooling status LED lights yellow One of the fans is defectiveServer Management Status HDD Ready Indicator does not light up Storage Subsystem Switches OFFSystem will not boot after Installation of New HDD Modules Hard Disk Drives dead on System Start Problem Solutions and Tips TroubleshootingConfiguration of the FFx-RAID controller incorrect FFx-RAID controller not configured for the hard disk driveAbbreviations IEC SCA Page Primergy S60 Related publicationsPage Cables IndexIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections

S60 specifications

Fujitsu Siemens Computers S60 is a notable offering from the collaboration between Fujitsu and Siemens, aimed at delivering high performance in the realm of desktop computing. Launched in the early 2000s, the S60 series represents a sophisticated blend of technology and design, appealing to both business users and tech enthusiasts alike.

One of the main features of the Fujitsu Siemens S60 is its robust hardware architecture. The system typically came equipped with Intel processors, ranging from Pentium 4 to Core 2 Duo, enabling seamless multitasking and efficient performance for various applications. With support for varying amounts of RAM, generally from 512MB to 4GB, the S60 catered to different user needs, whether for basic office tasks or more demanding software environments.

Storage options were versatile, featuring both traditional hard drives and the emerging SSD technology, allowing users to choose between speed and larger storage capacity. The inclusion of multiple USB ports facilitated easy connectivity with peripherals, such as printers, external drives, and various multimedia devices.

In terms of display technology, the Fujitsu Siemens S60 was compatible with a variety of monitors, including LCD displays which offered improved clarity and energy efficiency over traditional CRTs. The desktop's graphics capabilities were enhanced by integrated solutions from Intel, which provided adequate performance for standard business applications without needing a dedicated graphics card.

Another key characteristic is the emphasis on energy efficiency and eco-friendliness. Fujitsu Siemens prioritized the development of systems that met environmental standards, helping to minimize the carbon footprint of their products. This commitment is evident in their Energy Star-compliant designs, which aimed to reduce power consumption during operation.

The S60 series also featured various connectivity options, including Ethernet for network access and, in later models, wireless capabilities, giving users the flexibility to connect to the internet and enterprise resources effortlessly.

Adopting a modular design approach, the Fujitsu Siemens S60 made upgrades straightforward. Users could easily swap out components such as RAM, hard drives, and graphics cards, making the system highly adaptable to evolving technology needs.

Overall, the Fujitsu Siemens Computers S60 provided a comprehensive solution for users seeking a balanced combination of performance, expandability, and sustainability, making it a popular choice during its time. With its feature-rich specifications and forward-thinking design, the S60 left a lasting impression on the desktop computing landscape.