Fujitsu Siemens Computers S60 manual Routing the Cables, Leads Routing

Page 74

Mounting the Rack Model

Installation

10.4.4 Routing the Cables

The cables of the storage subsystem are routed in the rack in such a way that the unit can be pulled forwards without the cables having to be loosened.

The articulated cable guides on which the cables are routed are located in the interior of the DataCenter Rack (on the right if seen from the rear of the rack). The procedure can be found in the chapter “Cable Management“ in the DataCenter Rack manual.

1

Figure 28: Leads Routing

ÊConnect the cables to the system unit and to the storage subsystem.

VCAUTION!

The cables must have enough over-length when connecting to the storage subsystem (see figure 28). This is necessary to prevent them being pulled out of the connectors when the subsystem is withdrawn from the rack (the mains connectors could be pulled out unintentionally).

ÊRoute the cables as shown in the figure.

ÊInsert the cables through the articulated cable guides.

ÊSecure the cables with the cable ties (1).

66

U41221-J-Z156-1-74

Image 74
Contents Primergy S60 Storage Subsystem Comments… Suggestions… Corrections… Copyright and TrademarksGerman English Page Contents Contents Plug-in Board ModulesContents Page Introduction Server Management/ServerViewTarget Group Target GroupNotation Conventions BoldStructure of the Manual Technical Data Standards Complied With Maintenance Areas and Ventilation DistancesEnvironmental Conditions according to DIN EN Noise Development ISO Operation IdlePage Important Notes Important Notes Electrostatic Sensitive Device Label Electrostatic Sensitive Device ESD stickerFCC notices Federal Communications Commission CE certificateRFI Suppression CE certificateImportant Notes Environmentally friendly product design and development Environmental ProtectionEnvironmental Protection Take-back, recycling and disposal Further information on environmental protectionPage Operating and Indicator Elements FrontMeaning of the S60 Operating Status LEDs FrontOptical Waveguide Color Meaning Control LEDs for the Hard Disk Drives HddstatusLED Indication MeaningRear Side Rear SideFFx-RAID Controller Module LEDs Power Supply Unit LEDs Fault Operating Status of the power supply unitPosition Function Description Power SwitchSetting Fan LED Color Meaning Required MeasuresPage Removing and Mounting the door Open the HousingFloorstand Model Open the Housing Removing/Mounting the left Side CoverOpen the Housing Page Power Supply Power Supply UnitsReplacing the Power Supply Unit Power Supply UnitsInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page FC Hard Disk Drives Handling Hard Disk Drives/HDD ModulesRemoving the dummy module Installing/Removing HDD/Dummy ModuleInstalling/Removing HDD/Dummy Module Installing the HDD module FC Hard Disk DrivesTemperature difference C Minimum acclimatization time HoursRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page Plug-in Board Modules FFx-RAID Controller ModuleIndicators and Connectors FFx-RAID Controller ModuleDAC Element Label on the connection panelDescription of the LED indicators RedHssdc Pos. Description SwitchesRS232 Switch DIP Switches FFx-RAID Controller Module Switches on the Host AdapterInstalling/removing the FFx-RAID controller module DIP switch FunctionLoosen the knurled screw on the FFx-RAID controller module Adding a Second FFx-RAID Controller Module Removing the ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Connections Terminals on the Rear PanelFibre Channel FC Connection Fibre Channel FC ConnectionMains Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Installation StepsUnpacking the Storage Subsystem Setting Up the Floorstand ModelUnpacking the Storage Subsystem Mounting the Rack Model Preparing the Slide Rails Mounting the Rack ModelMounting Slide Rails Mounting the SubsystemRouting the Cables Leads RoutingArticulated Cable Guide Connecting leads Connecting and Disconnecting CablesConnecting and Disconnecting Cables Disconnecting leadsSwitching the Storage Subsystem ON/OFF Page Power Supply Status Indicator Front TroubleshootingProblem Solutions and Tips Power supply status indicator lights yellow Power supply status indicator lights orangeOne of the fans is defective Cooling StatusCooling status LED lights yellow Cooling status LED lights orangeServer Management Status HDD Ready Indicator does not light up Storage Subsystem Switches OFFSystem will not boot after Installation of New HDD Modules FFx-RAID controller not configured for the hard disk drive Problem Solutions and Tips TroubleshootingConfiguration of the FFx-RAID controller incorrect Hard Disk Drives dead on System StartAbbreviations IEC SCA Page Related publications Primergy S60Page Index CablesIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections