7 FC Hard Disk Drives

Up to fourteen one inch hard disk drives can be installed into the

PRIMERGY S60 storage subsystem. The FC hard disk drives can be controlled via up to two FC ports. The two FC ports are in each case over two outward lead Nodes in one loop. This means that each port is in one FC Loop (all ports A from the FC hard disk drives are in the same loop as the channel 0 from (both) FFx-RAID controller(s) and all ports B from the FC hard disk drives are in the same loop as the channel 1 from (both) FFx-RAID controller(s)).

The FC hard disk drives are built on a carrier which allows defective drives to be replaced (hot swap) or new drives to be added during operation. The hard disk drive and the carrier constitute the hard disk drive module (HDD module).

The hot-swap function can only be performed together with a corresponding RAID configuration. Further information about the RAID configuration or RAID level can be found in the RAID controller documentation.

A hard disk drive may only be replaced if it is inactive (see description of the LEDs in the table “Meaning of the HDD Control LEDs Indication” on page 19) or if it has been marked as defective in the management tool.

The hot swap procedure increases the availability of the system operation and guarantees a high degree of data integrity and protection against failure.

7.1Handling Hard Disk Drives/HDD Modules

Hard disk drives incorporated in the HDD modules are highly sensitive electro- magnetic devices and must be handled with great care. It is extremely likely that an incorrect handling will lead to a partially and/or total failure of the hard disk drives.

These failures will result in data errors and to loss of data or to total destruction of the hard disk drive.

Please observe following rules, which will help to avoid the occurrence of this type of problems:

Store and transport HDD modules only within the limits stipulated in the specification.

When transporting HDD modules (even over short distances), always use the original packaging (ESD labeling).

U41221-J-Z156-1-74

37

Image 45
Contents Primergy S60 Storage Subsystem Copyright and Trademarks Comments… Suggestions… Corrections…German English Page Contents Plug-in Board Modules ContentsContents Page Server Management/ServerView IntroductionNotation Conventions Target GroupTarget Group BoldStructure of the Manual Technical Data Environmental Conditions according to DIN EN Maintenance Areas and Ventilation DistancesStandards Complied With Noise Development ISO Operation IdlePage Important Notes Important Notes Electrostatic Sensitive Device ESD sticker Electrostatic Sensitive Device LabelRFI Suppression CE certificateFCC notices Federal Communications Commission CE certificateImportant Notes Environmental Protection Environmental ProtectionEnvironmentally friendly product design and development Further information on environmental protection Take-back, recycling and disposalPage Front Operating and Indicator ElementsFront Meaning of the S60 Operating Status LEDsOptical Waveguide Color Meaning Hddstatus Control LEDs for the Hard Disk DrivesIndication Meaning LEDRear Side FFx-RAID Controller Module LEDsRear Side Fault Operating Status of the power supply unit Power Supply Unit LEDsPower Switch SettingPosition Function Description Color Meaning Required Measures Fan LEDPage Open the Housing Floorstand ModelRemoving and Mounting the door Removing/Mounting the left Side Cover Open the HousingOpen the Housing Page Power Supply Units Power SupplyPower Supply Units Replacing the Power Supply UnitInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page Handling Hard Disk Drives/HDD Modules FC Hard Disk DrivesInstalling/Removing HDD/Dummy Module Installing/Removing HDD/Dummy ModuleRemoving the dummy module FC Hard Disk Drives Installing the HDD moduleHours Temperature difference C Minimum acclimatization timeRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page FFx-RAID Controller Module Plug-in Board ModulesFFx-RAID Controller Module Indicators and ConnectorsElement Label on the connection panel DACRed Description of the LED indicatorsHssdc Switches RS232 SwitchPos. Description FFx-RAID Controller Module Switches on the Host Adapter DIP SwitchesDIP switch Function Installing/removing the FFx-RAID controller moduleLoosen the knurled screw on the FFx-RAID controller module Removing the Module Adding a Second FFx-RAID Controller ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Terminals on the Rear Panel ConnectionsFibre Channel FC Connection Mains ConnectionFibre Channel FC Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Steps InstallationSetting Up the Floorstand Model Unpacking the Storage SubsystemUnpacking the Storage Subsystem Mounting the Rack Model Mounting the Rack Model Preparing the Slide RailsMounting the Subsystem Mounting Slide RailsLeads Routing Routing the CablesArticulated Cable Guide Connecting and Disconnecting Cables Connecting and Disconnecting CablesConnecting leads Disconnecting leadsSwitching the Storage Subsystem ON/OFF Page Troubleshooting Problem Solutions and TipsPower Supply Status Indicator Front Power supply status indicator lights orange Power supply status indicator lights yellowCooling status LED lights yellow Cooling StatusOne of the fans is defective Cooling status LED lights orangeServer Management Status Storage Subsystem Switches OFF System will not boot after Installation of New HDD ModulesHDD Ready Indicator does not light up Configuration of the FFx-RAID controller incorrect Problem Solutions and Tips TroubleshootingFFx-RAID controller not configured for the hard disk drive Hard Disk Drives dead on System StartAbbreviations IEC SCA Page Primergy S60 Related publicationsPage Cables IndexIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections