Fujitsu Siemens Computers S60 manual Rear Side, FFx-RAID Controller Module LEDs

Page 28

The Rear Side

Operating and Indicator Elements

3.2The Rear Side

On the rear side of the PRIMERGY S60 storage subsystem there are the status LEDs for the FFx-RAID controller module(s) and for the power supply units. Also the power switch is placed on this side.

1

6

2

3

4

5

Figure 4: Rear View of the PRIMERGY S60 Storage Subsystem

(1)FFx-RAID controller module 1

(2, 3) Power supply units

(4)Power switch

(5)FFx-RAID controller module 0 (default)

(6)Location for the optional Remote Service Board

3.2.1FFx-RAID Controller Module LEDs

The status LEDs are located on the connection panel of the FFx-RAID controller module. For description see section “The FFx-RAID Controller Module” on page 45.

20

U41221-J-Z156-1-74

Image 28
Contents Primergy S60 Storage Subsystem Comments… Suggestions… Corrections… Copyright and TrademarksGerman English Page Contents Contents Plug-in Board ModulesContents Page Introduction Server Management/ServerViewTarget Group Notation ConventionsTarget Group BoldStructure of the Manual Technical Data Maintenance Areas and Ventilation Distances Environmental Conditions according to DIN ENStandards Complied With Noise Development ISO Operation IdlePage Important Notes Important Notes Electrostatic Sensitive Device Label Electrostatic Sensitive Device ESD stickerCE certificate RFI SuppressionFCC notices Federal Communications Commission CE certificateImportant Notes Environmental Protection Environmental ProtectionEnvironmentally friendly product design and development Take-back, recycling and disposal Further information on environmental protectionPage Operating and Indicator Elements FrontMeaning of the S60 Operating Status LEDs Front Optical Waveguide Color Meaning Control LEDs for the Hard Disk Drives HddstatusLED Indication MeaningFFx-RAID Controller Module LEDs Rear SideRear Side Power Supply Unit LEDs Fault Operating Status of the power supply unitSetting Power SwitchPosition Function Description Fan LED Color Meaning Required MeasuresPage Floorstand Model Open the HousingRemoving and Mounting the door Open the Housing Removing/Mounting the left Side CoverOpen the Housing Page Power Supply Power Supply UnitsReplacing the Power Supply Unit Power Supply UnitsInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page FC Hard Disk Drives Handling Hard Disk Drives/HDD ModulesInstalling/Removing HDD/Dummy Module Installing/Removing HDD/Dummy ModuleRemoving the dummy module Installing the HDD module FC Hard Disk DrivesTemperature difference C Minimum acclimatization time HoursRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page Plug-in Board Modules FFx-RAID Controller ModuleIndicators and Connectors FFx-RAID Controller ModuleDAC Element Label on the connection panelDescription of the LED indicators RedHssdc RS232 Switch SwitchesPos. Description DIP Switches FFx-RAID Controller Module Switches on the Host AdapterInstalling/removing the FFx-RAID controller module DIP switch FunctionLoosen the knurled screw on the FFx-RAID controller module Adding a Second FFx-RAID Controller Module Removing the ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Connections Terminals on the Rear PanelMains Connection Fibre Channel FC ConnectionFibre Channel FC Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Installation StepsUnpacking the Storage Subsystem Setting Up the Floorstand ModelUnpacking the Storage Subsystem Mounting the Rack Model Preparing the Slide Rails Mounting the Rack ModelMounting Slide Rails Mounting the SubsystemRouting the Cables Leads RoutingArticulated Cable Guide Connecting and Disconnecting Cables Connecting and Disconnecting CablesConnecting leads Disconnecting leadsSwitching the Storage Subsystem ON/OFF Page Problem Solutions and Tips TroubleshootingPower Supply Status Indicator Front Power supply status indicator lights yellow Power supply status indicator lights orangeCooling Status Cooling status LED lights yellowOne of the fans is defective Cooling status LED lights orangeServer Management Status System will not boot after Installation of New HDD Modules Storage Subsystem Switches OFFHDD Ready Indicator does not light up Problem Solutions and Tips Troubleshooting Configuration of the FFx-RAID controller incorrectFFx-RAID controller not configured for the hard disk drive Hard Disk Drives dead on System StartAbbreviations IEC SCA Page Related publications Primergy S60Page Index CablesIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections