Fujitsu Siemens Computers S60 manual Power Switch, Position Function Description, Setting

Page 30

The Rear Side

Operating and Indicator Elements

3.2.3Power Switch

The power switch is located also on the rear of the PRIMERGY S60 storage subsystem. It is a slide switch with three possible settings.

I

R

O

Figure 6: Power Switch on the Rear of the PRIMERGY S60 Storage Subsystem

Position

Function

Description

 

 

 

(I)

local ON

The storage subsystem is switched ON permanently

 

 

and is connected directly to the mains (default

 

 

setting).

 

 

 

(R)

The operating mode (on/off) is controlled via the Remote Service

 

Board. In this default setting, the storage subsystem is switched

 

on and off simultaneously with the server. If two servers are

 

connected, it remains active as long as one of the servers is

 

switched on.

 

 

 

(O)

OFF

The storage subsystem is switched OFF permanently.

 

 

 

Table 4: Possible Settings of the Power Switch

22

U41221-J-Z156-1-74

Image 30
Contents Primergy S60 Storage Subsystem Comments… Suggestions… Corrections… Copyright and TrademarksGerman English Page Contents Contents Plug-in Board ModulesContents Page Introduction Server Management/ServerViewTarget Group Target GroupNotation Conventions BoldStructure of the Manual Technical Data Standards Complied With Maintenance Areas and Ventilation DistancesEnvironmental Conditions according to DIN EN Noise Development ISO Operation IdlePage Important Notes Important Notes Electrostatic Sensitive Device Label Electrostatic Sensitive Device ESD stickerFCC notices Federal Communications Commission CE certificateRFI Suppression CE certificateImportant Notes Environmental Protection Environmental ProtectionEnvironmentally friendly product design and development Take-back, recycling and disposal Further information on environmental protectionPage Operating and Indicator Elements FrontMeaning of the S60 Operating Status LEDs FrontOptical Waveguide Color Meaning Control LEDs for the Hard Disk Drives Hddstatus LED Indication MeaningRear Side FFx-RAID Controller Module LEDsRear Side Power Supply Unit LEDs Fault Operating Status of the power supply unitPower Switch SettingPosition Function Description Fan LED Color Meaning Required MeasuresPage Open the Housing Floorstand ModelRemoving and Mounting the door Open the Housing Removing/Mounting the left Side CoverOpen the Housing Page Power Supply Power Supply UnitsReplacing the Power Supply Unit Power Supply UnitsInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page FC Hard Disk Drives Handling Hard Disk Drives/HDD ModulesInstalling/Removing HDD/Dummy Module Installing/Removing HDD/Dummy ModuleRemoving the dummy module Installing the HDD module FC Hard Disk DrivesTemperature difference C Minimum acclimatization time HoursRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page Plug-in Board Modules FFx-RAID Controller ModuleIndicators and Connectors FFx-RAID Controller ModuleDAC Element Label on the connection panelDescription of the LED indicators RedHssdc Switches RS232 SwitchPos. Description DIP Switches FFx-RAID Controller Module Switches on the Host AdapterInstalling/removing the FFx-RAID controller module DIP switch FunctionLoosen the knurled screw on the FFx-RAID controller module Adding a Second FFx-RAID Controller Module Removing the ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Connections Terminals on the Rear PanelFibre Channel FC Connection Mains ConnectionFibre Channel FC Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Installation StepsSetting Up the Floorstand Model Unpacking the Storage SubsystemUnpacking the Storage Subsystem Mounting the Rack Model Preparing the Slide Rails Mounting the Rack ModelMounting Slide Rails Mounting the SubsystemRouting the Cables Leads RoutingArticulated Cable Guide Connecting leads Connecting and Disconnecting CablesConnecting and Disconnecting Cables Disconnecting leadsSwitching the Storage Subsystem ON/OFF Page Troubleshooting Problem Solutions and TipsPower Supply Status Indicator Front Power supply status indicator lights yellow Power supply status indicator lights orangeOne of the fans is defective Cooling StatusCooling status LED lights yellow Cooling status LED lights orangeServer Management Status Storage Subsystem Switches OFF System will not boot after Installation of New HDD ModulesHDD Ready Indicator does not light up FFx-RAID controller not configured for the hard disk drive Problem Solutions and Tips TroubleshootingConfiguration of the FFx-RAID controller incorrect Hard Disk Drives dead on System StartAbbreviations IEC SCA Page Related publications Primergy S60Page Index CablesIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections