Fujitsu Siemens Computers S60 manual Index

Page 92

Index

loop address 43 marking 43

HDD module acclimatization time 40, 61 carrier 37

dummy module 37, 39 handling 37, 42 hard disk drive 37 installing/removing 38 replace online 42

height units 1 high availability 29

I

indicator elements

control LEDs for the hard disk drives 15

fan LED 23

FFx-RAID controller module 20 operating status LEDs 15 power supply unit 21

installation

storage subsystem 61

L

low voltage directive 10

M

mains connection 58 phase redundancy 59

mains voltage status 17 maintenance area 5 manufacturer’s notes 10 mounting 26

N

noise immunity 5 noise level 5

O

operating status LEDs cooling status 16

mains voltage status 16 meaning 17

server management status 16

P

packing 12

plastic casing parts, adhesive labels 12

power supply status LED lights orange 72 lights yellow 72 remains dark 71

power supply unit coding 31 LEDs 21 redundancy 29 replacement 30

power switch 22 product safety 5

R

rack model holding-down clamp 64 mounting 63

slide rails 64 radio suppression 10 recycling, equipment 13 Remote Service Board (RSB) 1 returning, equipment 13

RSB (Remote Service Board) 1

S

safety instructions 7 saving energy 12 ServerView 1 side cover

removing 26 status LEDs 15 storage subsystem

installation 61 structure of the manual 3 subsystem

does not start up 75

84

U41221-J-Z156-1-74

Image 92
Contents Primergy S60 Storage Subsystem Comments… Suggestions… Corrections… Copyright and TrademarksGerman English Page Contents Contents Plug-in Board ModulesContents Page Introduction Server Management/ServerViewTarget Group Notation ConventionsTarget Group BoldStructure of the Manual Technical Data Maintenance Areas and Ventilation Distances Environmental Conditions according to DIN ENStandards Complied With Noise Development ISO Operation IdlePage Important Notes Important Notes Electrostatic Sensitive Device Label Electrostatic Sensitive Device ESD stickerCE certificate RFI SuppressionFCC notices Federal Communications Commission CE certificateImportant Notes Environmentally friendly product design and development Environmental ProtectionEnvironmental Protection Take-back, recycling and disposal Further information on environmental protectionPage Operating and Indicator Elements FrontMeaning of the S60 Operating Status LEDs FrontOptical Waveguide Color Meaning Control LEDs for the Hard Disk Drives HddstatusLED Indication MeaningRear Side Rear SideFFx-RAID Controller Module LEDs Power Supply Unit LEDs Fault Operating Status of the power supply unitPosition Function Description Power SwitchSetting Fan LED Color Meaning Required MeasuresPage Removing and Mounting the door Open the HousingFloorstand Model Open the Housing Removing/Mounting the left Side CoverOpen the Housing Page Power Supply Power Supply UnitsReplacing the Power Supply Unit Power Supply UnitsInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page FC Hard Disk Drives Handling Hard Disk Drives/HDD ModulesRemoving the dummy module Installing/Removing HDD/Dummy ModuleInstalling/Removing HDD/Dummy Module Installing the HDD module FC Hard Disk DrivesTemperature difference C Minimum acclimatization time HoursRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page Plug-in Board Modules FFx-RAID Controller ModuleIndicators and Connectors FFx-RAID Controller ModuleDAC Element Label on the connection panelDescription of the LED indicators RedHssdc Pos. Description SwitchesRS232 Switch DIP Switches FFx-RAID Controller Module Switches on the Host AdapterInstalling/removing the FFx-RAID controller module DIP switch FunctionLoosen the knurled screw on the FFx-RAID controller module Adding a Second FFx-RAID Controller Module Removing the ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Connections Terminals on the Rear PanelFibre Channel FC Connection Fibre Channel FC ConnectionMains Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Installation StepsUnpacking the Storage Subsystem Setting Up the Floorstand ModelUnpacking the Storage Subsystem Mounting the Rack Model Preparing the Slide Rails Mounting the Rack ModelMounting Slide Rails Mounting the SubsystemRouting the Cables Leads RoutingArticulated Cable Guide Connecting and Disconnecting Cables Connecting and Disconnecting CablesConnecting leads Disconnecting leadsSwitching the Storage Subsystem ON/OFF Page Power Supply Status Indicator Front TroubleshootingProblem Solutions and Tips Power supply status indicator lights yellow Power supply status indicator lights orangeCooling Status Cooling status LED lights yellowOne of the fans is defective Cooling status LED lights orangeServer Management Status HDD Ready Indicator does not light up Storage Subsystem Switches OFFSystem will not boot after Installation of New HDD Modules Problem Solutions and Tips Troubleshooting Configuration of the FFx-RAID controller incorrectFFx-RAID controller not configured for the hard disk drive Hard Disk Drives dead on System StartAbbreviations IEC SCA Page Related publications Primergy S60Page Index CablesIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections