Fujitsu Siemens Computers S60 manual

Page 88
Image 88
Contents Primergy S60 Storage Subsystem Comments… Suggestions… Corrections… Copyright and TrademarksGerman English Page Contents Contents Plug-in Board ModulesContents Page Introduction Server Management/ServerViewTarget Group Notation ConventionsTarget Group BoldStructure of the Manual Technical Data Maintenance Areas and Ventilation Distances Environmental Conditions according to DIN ENStandards Complied With Noise Development ISO Operation IdlePage Important Notes Important Notes Electrostatic Sensitive Device Label Electrostatic Sensitive Device ESD stickerCE certificate RFI SuppressionFCC notices Federal Communications Commission CE certificateImportant Notes Environmental Protection Environmental ProtectionEnvironmentally friendly product design and development Take-back, recycling and disposal Further information on environmental protectionPage Operating and Indicator Elements FrontMeaning of the S60 Operating Status LEDs FrontOptical Waveguide Color Meaning Control LEDs for the Hard Disk Drives HddstatusLED Indication MeaningFFx-RAID Controller Module LEDs Rear SideRear Side Power Supply Unit LEDs Fault Operating Status of the power supply unitSetting Power SwitchPosition Function Description Fan LED Color Meaning Required MeasuresPage Floorstand Model Open the HousingRemoving and Mounting the door Open the Housing Removing/Mounting the left Side CoverOpen the Housing Page Power Supply Power Supply UnitsReplacing the Power Supply Unit Power Supply UnitsInstalling occurs in reverse of order Page Fan Module Installing/Removing the Fan Module Installing/Removing the Fan ModuleProceed as follows when installing the fan module Page FC Hard Disk Drives Handling Hard Disk Drives/HDD ModulesInstalling/Removing HDD/Dummy Module Installing/Removing HDD/Dummy ModuleRemoving the dummy module Installing the HDD module FC Hard Disk DrivesTemperature difference C Minimum acclimatization time HoursRemoving occurs in reverse order Hot Swap for FC HDD Modules Hot Swap for FC HDD ModulesIdentification Marks and Loop Addresses Page Plug-in Board Modules FFx-RAID Controller ModuleIndicators and Connectors FFx-RAID Controller ModuleDAC Element Label on the connection panelDescription of the LED indicators RedHssdc RS232 Switch SwitchesPos. Description DIP Switches FFx-RAID Controller Module Switches on the Host AdapterInstalling/removing the FFx-RAID controller module DIP switch FunctionLoosen the knurled screw on the FFx-RAID controller module Adding a Second FFx-RAID Controller Module Removing the ModuleFFx-BBU Battery Backup Unit Module Conditioning the Battery Connections Terminals on the Rear PanelMains Connection Fibre Channel FC ConnectionFibre Channel FC Connection Mains Connection with Phase Redundancy Mains Connection with Phase RedundancyPower connection via UPS Power connection via UPSInstallation Installation StepsUnpacking the Storage Subsystem Setting Up the Floorstand ModelUnpacking the Storage Subsystem Mounting the Rack Model Preparing the Slide Rails Mounting the Rack ModelMounting Slide Rails Mounting the SubsystemRouting the Cables Leads RoutingArticulated Cable Guide Connecting and Disconnecting Cables Connecting and Disconnecting CablesConnecting leads Disconnecting leadsSwitching the Storage Subsystem ON/OFF Page Problem Solutions and Tips TroubleshootingPower Supply Status Indicator Front Power supply status indicator lights yellow Power supply status indicator lights orangeCooling Status Cooling status LED lights yellowOne of the fans is defective Cooling status LED lights orangeServer Management Status System will not boot after Installation of New HDD Modules Storage Subsystem Switches OFFHDD Ready Indicator does not light up Problem Solutions and Tips Troubleshooting Configuration of the FFx-RAID controller incorrectFFx-RAID controller not configured for the hard disk drive Hard Disk Drives dead on System StartAbbreviations IEC SCA Page Related publications Primergy S60Page Index CablesIndex Index Unpacking Page Comments Suggestions Corrections Page Comments Suggestions Corrections

S60 specifications

Fujitsu Siemens Computers S60 is a notable offering from the collaboration between Fujitsu and Siemens, aimed at delivering high performance in the realm of desktop computing. Launched in the early 2000s, the S60 series represents a sophisticated blend of technology and design, appealing to both business users and tech enthusiasts alike.

One of the main features of the Fujitsu Siemens S60 is its robust hardware architecture. The system typically came equipped with Intel processors, ranging from Pentium 4 to Core 2 Duo, enabling seamless multitasking and efficient performance for various applications. With support for varying amounts of RAM, generally from 512MB to 4GB, the S60 catered to different user needs, whether for basic office tasks or more demanding software environments.

Storage options were versatile, featuring both traditional hard drives and the emerging SSD technology, allowing users to choose between speed and larger storage capacity. The inclusion of multiple USB ports facilitated easy connectivity with peripherals, such as printers, external drives, and various multimedia devices.

In terms of display technology, the Fujitsu Siemens S60 was compatible with a variety of monitors, including LCD displays which offered improved clarity and energy efficiency over traditional CRTs. The desktop's graphics capabilities were enhanced by integrated solutions from Intel, which provided adequate performance for standard business applications without needing a dedicated graphics card.

Another key characteristic is the emphasis on energy efficiency and eco-friendliness. Fujitsu Siemens prioritized the development of systems that met environmental standards, helping to minimize the carbon footprint of their products. This commitment is evident in their Energy Star-compliant designs, which aimed to reduce power consumption during operation.

The S60 series also featured various connectivity options, including Ethernet for network access and, in later models, wireless capabilities, giving users the flexibility to connect to the internet and enterprise resources effortlessly.

Adopting a modular design approach, the Fujitsu Siemens S60 made upgrades straightforward. Users could easily swap out components such as RAM, hard drives, and graphics cards, making the system highly adaptable to evolving technology needs.

Overall, the Fujitsu Siemens Computers S60 provided a comprehensive solution for users seeking a balanced combination of performance, expandability, and sustainability, making it a popular choice during its time. With its feature-rich specifications and forward-thinking design, the S60 left a lasting impression on the desktop computing landscape.