Chapter 1 Product Overview
Fan Module
Table | Power Supply Module Status LED |
|
|
Color | System Status |
|
|
Green | The power supply module is installed, output is OK, all internal fans OK, and power |
| switch is ON. |
|
|
Red | The power supply module is installed, output has failed or one of the internal fans has |
| failed, power switch is ON. |
|
|
Off | The power supply module is installed, power switch is OFF, no input power, or invalid |
| input power. |
|
|
Table | Power Supply Input LED |
|
|
Color | System Status |
|
|
Green | The power supply module is installed, AC or DC input power is OK, power switch can |
| ON or OFF. |
|
|
Amber | The power supply module is installed, AC or DC input power is insufficient or not present |
| and a redundant power supply is functioning properly. |
|
|
Off | The power supply module is installed, no input power present at both power supply |
| modules. |
|
|
Fan Module
The fan module provides cooling and proper airflow when only one power supply module is installed. The fan module is
Caution Both slots must be occupied either by two power supply modules or a power supply and a fan module. Do not run the switch with an empty slot unless you are replacing a faulty power supply or fan module. Running the switch with an empty slot triggers an alarm.
Each fan module contains three fans. The switch can operate safely if one fan fails. A fan failure triggers an alarm. When a fan fails, replace the fan module immediately.
| Cisco ME 3800X and ME 3600X Switch Hardware Installation Guide |