Cisco Systems ME3600X24CXM manual Dwdm

Page 72

Appendix B Connector and Cable Specifications

Cables and Adapters

Table B-2

Fiber-Optic SFP Module Port Cabling Specifications (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

Core

Modal

 

 

 

Wavelength

 

Size/Cladding

Bandwidth

 

SFP Module

 

(nanometers)

Fiber Type

Size (micron)

(MHz/km)1

Cable Distance

DWDM

 

1560.61, 1559.79,

SMF

G.6522

62 miles (100 km)

 

 

1558.98, 1558.17,

 

 

 

 

 

 

1556.55, 1554.55,

 

 

 

 

 

 

1554.94, 1554.13,

 

 

 

 

 

 

1552.13, 1551.72,

 

 

 

 

 

 

1550.92, 1550.12,

 

 

 

 

 

 

1548.51, 1547.72,

 

 

 

 

 

 

1546.92, 1546.12,

 

 

 

 

 

 

1546.12, 1544.53,

 

 

 

 

 

 

1543.73, 1542.94,

 

 

 

 

 

 

1542.14, 1540.56,

 

 

 

 

 

 

1539.77, 1538.98,

 

 

 

 

 

 

1536.61, 1535.82,

 

 

 

 

 

 

1535.04, 1534.25,

 

 

 

 

 

 

1532.68, 1531.90,

 

 

 

 

 

 

1531.12, 1530.33

 

 

 

 

 

 

 

 

 

 

 

10GBASE-LR

 

1310

SMF

G.6522

 

6.21 miles (10 km)

(SFP-10G-LR)

 

 

 

 

 

 

 

 

 

 

 

 

 

10GBASE-SR

 

850

MMF

62.5/125

160

85 feet (26 m)

(SFP-10G-SR)

 

 

 

62.5/125

200

108 feet (33 m)

 

 

 

 

50/125

400

216 feet (66 m)

 

 

 

 

50/125

500

269 feet (82 m)

 

 

 

 

50/125

2000

6,561 feet (2000 m)

 

 

 

 

 

 

 

10GBASE-CX1

 

 

 

(SFP-H10GB-CU1M)

 

Twinax cable, 30-AW

 

 

3 feet (1 m)

 

 

 

cable assembly

 

 

 

(SFP-H10GB-CU3M)

 

Twinax cable, 24-AWG

 

 

9 feet (3 m)

 

 

 

cable assembly

 

 

 

 

 

 

 

 

(SFP-H10GB-CU5M)

 

Twinax cable, 30-AWG

 

 

16 feet (5 m)

 

 

 

cable assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Modal bandwidth applies only to multimode fiber.

2.A mode-field diameter/cladding diameter = 9 micrometers/125 micrometers.

3.Requires a mode-conditioning patch cord. An ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules, and a short link distance can cause transceiver saturation, resulting in an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the link. Link distances greater than 984 feet (300 m) require the mode-conditioning patch cord.

4.1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends on the fiber quality, the number of splices, and the connectors.

Note When the fiber-optic cable span is less than 15.43 miles (25 km), you should insert a 5-decibel (dB) or 10-dB inline optical attenuator between the fiber-optic cable plant and the receiving port on the 1000BASE-ZX SFP module at each end of the link.

Cisco ME 3800X and ME 3600X Switch Hardware Installation Guide

 

B-6

OL-22168-01

 

 

 

Image 72
Contents Americas Headquarters Text Part Number OL-22168-01Page Audience PurposeRelated Publications Obtaining Documentation and Submitting a Service Request OL-22168-01 Setting Up the Switch Switch ModelsSwitch Model Description Front PanelAlarm Input Port Bits PortManagement and Console Port 10/100/1000 Gigabit Ethernet PortsSFP+ and SFP Modules Part Number Description Dwdm CAB-SFP-50CMSD Memory Slot LEDsSFP Module Patch Cable Switch LED Panels System LED DescriptionColor System Status Power Supply Module Input LED Description Power Supply and Fan LED DescriptionEthernet Management Port LED Description Alarm LEDs Description Sync LED DescriptionSD Card LED Description Rear Panel Port LEDs DescriptionLED Color Meaning Power Supply Module Features Power Supply Module LEDsFan Module Management Options Fan Module LEDNetwork Configurations Switch Installation Switch Installation 122F 50C Statement Installation Guidelines Verifying Switch OperationInstalling the Switch Powering Off the SwitchRack-Mounting Attaching Brackets to the Switch Rack-Mounting BracketsAttaching Brackets for 19-Inch Racks Attaching Brackets for 23-Inch Racks Attaching Brackets for Etsi Racks Attaching Angle Brackets for 23-Inch Racks Mounting the Switch Mounting in a RackMounting the Switch Using 23-Inch Angle Brackets Wall-Mounting Attaching Brackets for Wall-MountingMounting the Switch on a Wall Mounting Cisco ME 3800X on a WallInstalling and Removing SFP+ and SFP Modules Installing SFP+ and SFP ModulesTable- or Shelf-Mounting 11 Installing an SFP+ Module into an SFP+ Module Slot Removing SFP+ or SFP ModulesInserting and Removing the SFP+ Module Patch Cable 12 Removing a Bale-Clasp Latch SFP+ Module14 Connecting Two Switches with an SFP+ Module Patch Cable Connecting to the 10/100/1000 Ports 15 Connecting to an Ethernet PortConnecting to Fiber-Optic SFP+ and SFP Modules Where to Go NextPower Supply Module Description Model number DescriptionAC Input Power Supply Module Handle Side Connector-Side Description Fan Module DescriptionPower Supply and Fan Module Installation Installation GuidelinesEquipment That You Supply Installing an AC Power Supply Module AC-1 PSU-1 AC-2 PSU-2Removing AC Power Supply Modules AC Power Supply Module and Power-Cord Retainer in a SwitchInstalling a DC Power Supply Module Preparing for InstallationGrounding the Switch Stripping the Ground WireCrimping the Ground Lug Installing the DC Power Supply Module in the Switch Wiring the DC Input Power Source24VDC 30A Inch 8.9 mm ± 0.02 inch 0.5 mm 3 Wire lead Insulation Removing the DC Power Supply Module Installing a Fan Module 14 Inserting a Fan Module in a SwitchOL-22168-01 Diagnosing Problems Switch Post ResultsSwitch LEDs Switch ConnectionsBad or Damaged Cable Ethernet and Fiber CablesSFP+ and SFP Module Port Issues Port and Interface SettingsPing the End Device Spanning Tree LoopsClearing the Switch IP Address and Configuration Switch PerformanceSpeed, Duplex, and Autonegotiation Autonegotiation and NICsFinding the Switch Serial Number Serial Number Location on the Cisco ME 3800X and MEOL-22168-01 Technical Specifications Environmental RangesPhysical Dimensions AC Power RequirementsDC Power Requirements Table A-3 Technical Specifications-ME-3600X-24FS-M Table A-4 Technical Specifications-ME-3600X-24TS-M Physical Specifications Power SpecificationsOL-22168-01 Connector Specifications 10/100/1000SFP and SFP+ Module Connectors Copper SFP Module RJ-45 Connector10/100/1000 Ethernet Management Port Figure B-5 SFP Module Patch CablePin Signal Direction Description TX TIPCables and Adapters SFP and SFP+ Module CablingCore Modal Wavelength Dwdm Cable Pinouts TP3Console Port Adapter Pinouts Figure B-11Switch Console RJ-45-to-DB-25 Port DTE DSR DTR CTS RTSOL-22168-01 Accessing the CLI Through the Console Port Starting the Terminal-Emulation SoftwareEntering the Initial Configuration Information IP SettingsCompleting the Setup Program Enter an enable password, and press Return These choices appear