Cabletron Systems 9A100 manual AtmAddress, Atmroute

Page 45

Switch Administration

ATMRouting

4.Enter the add ATMRoute command to create a static route to the IISP device:

SmartSwitch # add atmroute

PortNumber(A1) : b2

AtmAddress() : 52:00:00:00:00:00:00:00:00:00:14:51:80

PrefixLength(104) :

Index(0) :

Type(Internal) :exterior

Scope(0) :

MetricsTag(0) :

SmartSwitch #

Note The add ATMRoute command allows you to specify a set of metrics to be used with the route. For more on metrics and metric tags, see Section 4.2.3 “Route Metrics.”

5.Enter the show ATMRoute command to determine whether the route was created:

SmartSwitch # show

atmroute

 

AddressNumber(ALL)

 

:

No. Port Route Address

Type Protocol

================================================================================

1

B4

39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:80

I

MGMT

2

B4

39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:81

I

MGMT

3

--

39:00:00:00:00:00:00:00:00:00:14:59:00

I

PNNI

4

--

39:00:00:00:00:00:00:00:00:00:28:e9:80

I

PNNI

5

--

39:00:00:00:00:00:00:00:00:00:28:f5:00

I

PNNI

6

B4

47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01

I

MGMT

7

B2

52:00:00:00:00:00:00:00:00:00:14:51:80

I

MGMT

SmartSwitch #

The route to the IISP device appears on the last line (Route No. 7).

6.Create a route on the IISP device that refers to the net prefix

(39:00:00:00:00:00:00:00:00:00:14:41:80) of port b2 on the SmartSwitch 9A100.

Note For IISP routes to work with certain devices, ILMI may also need to be disabled on the SmartSwitch 9A100. Use the set PortConfig command to disable ILMI on the SmartSwitch 9A100 on a per-port basis.

IISP Routing Considerations

When creating routes between the SmartSwitch 9A100 (running PNNI) and IISP devices, the criteria that characterize IISP connectivity still apply. To reach a SmartSwitch 9A100 within the PNNI domain, the IISP device must have a configured route that points directly to a port on the target SmartSwitch 9A100. Conversely, there must be a SmartCell 9A100 that has a direct physical link (and a route over that link) to the IISP device. The following two examples illustrate this point.

In Figure 4-1 Switch A is an IISP device connected to the PNNI domain through Switch B. Switch A contains an LEC, which is a member of an ELAN whose LECS is on Switch C (within the PNNI domain). If the LEC on Switch A is to make contact with the LECS on Switch C, Switch A must contain an IISP route (denoted by the dotted line) directly to switch C. Furthermore, Switch B must contain a route to switch A over the physical link that connects the two switches.

SmartSwitch 9A100 User Guide 4-3

Image 45
Contents SmartSwitch 9A100 User Guide SmartSwitch 9A100 User Guide FCC Class a Notice Declaration of Conformity Addendum Safety Information Class 1 Laser Transceivers Fiber Optic Protective Caps Regulatory Compliance Summary Safety Revision History Table of Contents Specifications Acronyms Index Xii SmartSwitch 9A100 User Guide List of Figures List of Figures Xiv SmartSwitch 9A100 User Guide List of Tables List of Tables Xvi SmartSwitch 9A100 User Guide Introduction Introduction SmartSwitch 9A100 User Guide Switch Installation and Setup Unpacking the SwitchCheck Accessory Carton Contents SmartSwitch 9A100-04 front panel Inspecting the Switch1 DS3 and E3 I/O Module Configuration Installing the Switch Installing the SmartSwitch 9A100 Configuring the Switch SmartSwitch 9A100 console and network connections Console Commands Using the ConsoleSmartSwitch # show portconfig a1 Console Time-out SmartSwitch # set consoletimeoutCreating an Alias TrafficSwitchTrafficCongestion. For example Ambiguous CommandsSmartSwitch # ? add laneclient Smartswitch ATM AdministratorConsole Help ExteriorSmartSwitch ATM Administrator MB RAM Installation StepsStarting SmartSwitch ATM Administrator the First Time Accessing Online HelpUser Name Access Level Default Password SmartSwitch ATM Administrator SmartSwitch # add ipatmclient IP Over ATM and LaneCreating AN IP Over ATM Vlan Server Is local Server Connection Established Creating AN Emulated LAN ATM Addressing for IP over ATM3900000000000000000014418000005A01010100 No Lane server address is specified see note below Add ElanIlmi ATM Addressing for LAN Emulation ELANs Across Multiple SwitchesSwitch Clients SmartSwitch# add laneclientElan1 Page Switch Administration Backing UP and Restoring Switch ConfigurationPath /backdir/config-1 SmartSwitch # show netprefix b2 SmartSwitch# restore switchATM Routing Creating an Iisp RouteAtmroute AtmAddressIisp route across Pnni domain UNI Routes Route Metrics IP Routing SmartSwitch # show pnnimetricsRoute NET Table 90.1.1.254Event Categories Events and AlarmsSmartSwitch # set eventdisplay Viewing Events and AlarmsDeleting Events and Alarms SmartSwitch # set alarmdisplayPVC Connections SmartSwitch # show trafficdescriptor SmartSwitch # add trafficdescriptorPoint-to-Point PVCs 100Md1 #add trafficdescriptor Point-to-Multipoint PVCsConnecting to Local Switch Client Through a PVC Local10.1.1.0 VCC Mask Index VPI Bits VPI Values VCI Bits VCI Values Non-zero VPIsSmartSwitch # set portconfig a1 Use show portconfig to see the change to port A1Traffic Descriptors Traffic ManagementTraffic Descriptor with CLP and best effort Type Number Descriptor CharacteristicsCall Admission Control Policy 80005000 Ubr Min for CBR queue SmartSwitch # set porttrafficcongestionQoS Queue Recommended Settings SmartSwitch # show switchtrafficcongestionEFCI, EPD, and RM Thresholds Upgrading and Changing Software Accessing the Boot Load PromptCommand Action Parameters Boot Load CommandsUpgrading Boot Load Software Boot PromFlash RAM =df b Upgrading Post Diagnostic Software =chpi=df p =df s Upgrading Switch Operating SoftwareUsing the Update Firmware Command SmartSwitch # update firmware214.95.77.240 Saving Core Dumps Set CoreDump command Tftpboot/bobr/core204.95.77.240 BobrError IP e0103288 PFP e04be080 R0pfp e04be040 R1sp e04be0c0 Troubleshooting IP Over ATM TroubleshootingTroubleshooting LAN Emulation Troubleshooting Pnni Links Troubleshooting Congestion Diagnosing CongestionGlobal Congestion Port Congestion Troubleshooting Congestion Function Appendix a SpecificationsFigure A-1 SmartSwitch 9A100 front panel ¢ %+2,%/˜96%,,%,329 Specification ValueProtocol Standard Table A-4 ATM port specificationsRJ-45 Pin RJ-45 Color DB-9 Pin DB-9 Description Management Protocol Supported MIBsTechnical Specifications MIB, SMI, MIB Files and Internet MIB Hierarchy Appendix B Agent SupportMIB, SMI, MIB Files and Internet MIB Hierarchy ZeitNet Cabletron Proprietary MIBsRelation Between Object Identifier and the Represented Value Supported SMI Formats Supported protocolsName Object Identifier Function Zeitnet Cabletron Proprietary MIB GroupsMIB Exceptions SmartSwitch 9A100 MIB SupportManaging the SmartSwitch 9A100 Update firmware Backup Restore Reboot Console Commands that Affect the AgentElectronic Services FAX ServiceAppendix C Technical Support Telephone AssistanceHardware Warranty Software WarrantyRepair Services Appendix D Acronyms Bootp DTE FCS Ilmi LES Netbeui PDU RMA SVC VBR/RT Acronyms SmartSwitch 9A100 User Guide Numerics IndexElan Lane Snmp Lane Pnni Non-zero values